High pressure vortex fan aerator fish pond aeration power strong suction blowing

NegotiableUpdate on 02/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
High pressure vortex fan aerator fish pond aeration power strong suction blowing is one of the most efficient mechanical equipment for achieving high yields in aquaculture. Reasonable use of aerators can not only prevent and reduce floating heads, but also improve water quality, strengthen pond water circulation, and promote plankton reproduction. It is one of the commonly used aquaculture machinery in the current aquaculture industry. Mainly used to increase the oxygen content in fish pond water and meet the oxygen requirements for fish growth and development. This aerator has a fast oxygenation rate and can effectively and quickly deal with fish head floating and death caused by oxygen deficiency in the fish pond
Product Details

High pressure vortex fan aerator fish pond aeration power strong suction blowingIt is widely used in industrial machinery and equipment, and is also suitable for dust collection equipment in industrial plants and workshops such as vacuum cleaners, dust collectors, and dust collectors. The vortex high-pressure blower has stable flow, high efficiency, and low energy consumption: therefore, any method such as blowing, spraying, and suction has its effectiveness, and has a relatively conservative design in the high-pressure range. It can still operate safely when there are changes in usage.

Large fish pond oxygenation and aeration high-pressure fanInstallation of:

A、 Installation location:The surrounding temperature and humidity should meet the following conditions:

1. Single phase -5~40 ℃ Three phase -10~40 ℃

2. Choose a place with good ventilation, less dust and moisture.

3. For outdoor installations, please use a rain cover.

B、 Installation method:The high-pressure fan can be installed at any angle and securely fixed to a horizontal and rigid foundation or base with screws. The standard weight is approximately three times or more that of a high-pressure fan. Special attention should be paid to whether the base is uneven. If so, the high-pressure fan machine may deform when the bolts are tightened! Shock absorbers can be installed to reduce noise. When the ventilation duct is not connected to the suction port, please install wire mesh or filter to prevent danger or foreign matter inhalation.

fishThe pond oxygen blower has six major characteristics:

1. Oxygen storage: Due to the bubbles generated by ultrafine pore aeration, the contact surface with water in the water is large, the upward flow velocity is low, and the contact time is long, resulting in high oxygen mass transfer efficiency.

2. Activating water bodies: Micro porous aeration and oxygenation devices are like turning water bodies into billions of slowly flowing rivers. Adequate dissolved oxygen enables water bodies to establish natural ecosystems and bring water to life.

3. Restore the self purification function of water bodies: Micro porous aeration oxygenation is bottom oxygenation, while other oxygenation is surface oxygenation. Aquaculture water bodies mainly suffer from bottom hypoxia, and difficult to solve organic matter such as fertilizer sludge, organic excrement, and remaining spoiled feed in the bottom of the water consume a large amount of oxygen. Adequate micro porous aeration oxygenation converts it into organic matter dissolved and decomposed by microorganisms, restoring the self purification function of the water body.

4. Ultra low energy consumption: Due to the use of microporous aeration oxygenation equipment, the mass transfer efficiency of oxygen *, the dissolved oxygen per unit of water quickly reaches about 4.5mg/L, which is less than a quarter of the energy consumption of water trucks or impellers for oxygenation, and can greatly save the electricity cost of farmers.

5. Realize ecological aquaculture and ensure aquaculture benefits: Continuous micro pore oxygenation provides sufficient dissolved oxygen for the water body, restoring and improving the self purification ability of the water body. The natural balance of bacterial and algal phases builds a natural ecology of the water body, stabilizing the survival ability of aquaculture populations and fully ensuring aquaculture benefits.

6. Safety and Environmental Protection: The microporous aeration oxygenation device is installed on the shore with good safety performance and will not cause any pollution to the water body. Other oxygenation methods work in water and are prone to leakage, which may pose potential hazards to human health and fish and shrimp.

Vortex high-pressure vacuum pumpInstallation precautions:

1. Flat washers and spring washers must be used to tighten screws;
2. Can use rubber buffer to withstandVortex high-pressure air pumpThe weight, especially high-power onesVortex high-pressure air pump
3. For certain occasions where noise is required, a silencer can be installed to reduce noise (usually around 5dB). The silencer is installed at the end of the inlet or outlet duct;
4. For certain occasions with high noise requirements, a layer of soundproofing can be added according to the machine's own conditions to meet the on-site noise requirements. For specific details, please consult our company.
5. When using the silencing setting, pay attention to the distance between the vortex fan and the box, the ventilation and heat dissipation of the fan, and the use of rubber buffer to withstand itVortex high-pressure air pumpThe specific weight needs to be consulted with our company's staff;
6. The inlet and outlet pipes of the vortex fan should be connected using hoses to isolate vibration.

Before use, it is necessary to understand:

1. Carefully read the fan user manual and product samples, familiarize and understand the specifications, form, impeller rotation direction, and airflow inlet and outlet direction of the fan; Recheck if all components of the fan are intact, otherwise they should be repaired before installation and use.

2. When installing the fan, safety devices must be installed to prevent accidents, and it must be installed and wired by professionals familiar with relevant safety requirements.

3. The air ducts connecting the inlet and outlet of the fan are separately supported, and it is not allowed to add overlapping weight to the components of the fan; When installing the fan, attention should be paid to the horizontal position of the fan. The connection between the fan and the foundation and the air outlet duct should be adjusted to fit naturally, and forced connection is not allowed.

4. After installing the fan, use your hand or lever to move the impeller and check for any tightness or rubbing, as well as any objects that may hinder rotation. Only when there are no abnormal phenomena can the test run be carried out. The exposed part of the fan transmission device should have a protective cover (provided by the user). If the fan inlet is not connected to the pipeline, a protective net or other installation device (provided by the user) should also be added.

5. The distribution control box of the fan must be matched with the corresponding fan (referring to power, voltage, pneumatic mode, control form, etc.).

6. The wiring of the fan should be done by a professional electrician, and the wiring must be correct and reliable, especially the wiring number at the electrical control box should correspond to the number * on the fan terminal post. The fan housing should be reliably grounded, and the grounding must be reliable. Zero grounding cannot be used instead of grounding.

7. After installing all the fans, check whether there are any remaining tool boxes or debris inside the fans

High pressure vortex fan aerator fish pond aeration power strong suction blowingApplicable industries:

1. Applied to the drying industry, boiler industry, cleaning industry, coating industry, food drying industry, vacuum packaging industry

2. The operating temperature is between 100 ℃ and 180 ℃.

3. The transported gas is air or other non self igniting, non exploding, non entangling, harmless to the human body, and non corrosive to steel materials. It can also be used to transport non corrosive, non self igniting, and non viscous hot gases, vapors, and smoke in various industries. Other materials with similar performance can also be selected, but the temperature of the conveying medium must not exceed its rated temperature range.

4. There shall be no viscous substances in the gas, and the dust and hard particles contained shall not exceed 150mg/m3. If the dust content is high, a dust removal device with a readiness of not less than 85% must be installed before the fan to reduce the dust content of the flue gas entering the fan and improve the service life of the fan.