The high-temperature pipeline smoke, dust turbidity and dust monitoring instrument adopts high-temperature resistant and corrosion-resistant materials, which are suitable for harsh industrial environments. Some models have explosion-proof certification, meeting the requirements of flammable and explosive scenarios. Resistant to high temperature, high pressure, and high humidity, suitable for heavy industrial scenarios such as metallurgy, chemical engineering, and power.
High temperature pipeline smoke, dust turbidity, and dust monitoring instrumentProduct function
Safety protection: Real time warning of high concentration dust, avoiding explosion risks, and ensuring the safety of personnel and equipment.
Environmental compliance: Provide accurate emission data to help companies cope with environmental inspections and avoid fines.
Health protection: Reduce the occurrence of occupational diseases and improve employee job satisfaction.
Production optimization: Adjust process parameters through data feedback to improve production efficiency and product quality.
Cost savings: reduce energy consumption of dust removal equipment, minimize raw material loss, and extend equipment lifespan.
High temperature pipeline smoke, dust turbidity, and dust monitoring instrumentTechnical Specifications:
1. Output mode: 4-20mA (or RS485 communication, Modbus RTU protocol, switch quantity, etc.),
Advantages of HART Protocol - Export Equipment Customization:
Simultaneously including analog and digital communication, compatible with traditional analog instrument solutions, supporting multivariable field devices, flexible data access through two hosts, de facto open standards, backward compatibilityCan support both analog and digital protocols, unlike other fieldbuses that are essentially digital, point-to-point or multi-point operations, with a response time of approximately 0.5 seconds. The HART protocol is a unique backward compatible communication facility that ensures that existing investments in factory cables and power requirements remain secure in the future. It is a communication facility that supports both analog and digital communication (hybrid) simultaneously. By retaining the traditional 4-20 mA signal, it extends the bidirectional digital communication capability between the system and multivariable intelligent field instruments. Any process application can be serviced and processed by the HART protocol.
2. Wire system: 2-wire system, 4-wire system
3. Display: Yes or No Display
4. Pipeline gas temperature: Conventional 0 ℃~250 ℃, High temperature type 260 ℃~800 ℃ can be customized
5. Is there an alarm: Yes, No
6. Do you need an isolator (function?): Yes (built-in is an advantage, others are external), No need
6. Range: 0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (special ranges can be customized)
7. Principle: Electrostatic Induction Principle

technical specifications
Operating environment temperature |
-20 ℃~60 ℃ (electronic components) |
Operating environment humidity |
Non condensing 90% |
Operating environment vibration |
Maximum continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2) |
Operating environment electromagnetic field |
At 50 Hz, the maximum value is 60 A/m (equivalent to a magnetic field of 50 AT in a 1 meter x 1 meter square electromagnetic coil) |
Protection of operating environment |
Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe |
Pipeline gas pressure |
-0.1-1MPa (maximum up to 8MPa) |
Pipeline gas flow rate |
1m/s~30m/s |
Pipeline gas temperature |
Real time temperature: 200 ℃, instantaneous temperature: 260 ℃ (260 ℃ -800 ℃ can be customized) |
outer diameter of pipe |
0.1 meters to 4 meters |
Probe structure |
The standard probe is 16mm in diameter, with a length ranging from 100mm to 1000mm. The probe material is rare earth amorphous alloy, |
Dust particle size range |
The nominal range is 0.1 μ M to 200 μ M, and it can still receive signals outside the nominal range, but the signal characteristics are slightly different. |
Powder material |
Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter |
zero drift |
(Time) Less than 1% of the range per year. |
zero drift |
Within the specified temperature range, below 1% of the measuring range. |
Full-scale drift |
(Time) Less than 1% of range per year |
Full-scale drift |
Within the specified temperature range, below 1% of the measuring range. |
Line stability |
All components of the system are made of high stability electronic assemblies. |
Noise resistance |
All 50 or 60 Hz audio and harmonics are filtered out before the signal is received |
measurement range |
0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (customized for special ranges) |
Transmitter output mode |
Standard 4-20mA (two-wire system) (customizable switch quantity, RS485 communication, Modbus RTU protocol, HART protocol, etc.) |
Transmitter power supply |
24V (available within the range of 15V to 32V) |
measurement accuracy |
±1% |
Probe length selection |
Please select the probe length according to the formula, i.e. D/3 ≤ L ≤ 2D/3
(Among them: D - Inner diameter of pipeline, L - Probe length)
|
Explosion-proof marking |
Exia IIC T6 Ga/ExoD 21 T80 ℃ Certificate Number: CNV21.0092X
Ex db IIC T6 Gb, Ex tb IIC T80 ℃ Db Certificate Number: CNV24.1117X
|