E-mail
nenghua@nenghua.net
-
Phone
17156775888
-
Address
15th Floor, Building 1, United Fortune Plaza, High tech Zone, Jinan City, Shandong Province
Jinan Nenghua Electromechanical Equipment Co., Ltd
nenghua@nenghua.net
17156775888
15th Floor, Building 1, United Fortune Plaza, High tech Zone, Jinan City, Shandong Province
| Model (NHDA) | 1KVA-6002 | 2KVA-6002 | 3KVA-6002 | 5KVA-6002 | 8KVA-6002 | 10KVA-6002 | 15KVA-6002 | 20KVA-6002 | 30KVA-6002 | 40KVA-6002 | |
| 功率 (Kva) | 1 | 2 | 3 | 5 | 8 | 10 | 15 | 20 | 30 | 40 | |
| direct current Input |
Rated voltage (V)DC) | 600 | |||||||||
| Input voltage (V)DC) | 400-800 | ||||||||||
| communication output | Output rated voltage and frequency | 220VAC,50Hz | |||||||||
| Output voltage accuracy (V) | 220±2% | ||||||||||
| Output frequency accuracy (Hz) | 50±0.05% | ||||||||||
| Waveform Distortion Rate (THD) (Linear load) |
≤3% | ||||||||||
| dynamic response time (Load 0 ← → 100%) |
5% | ||||||||||
| Power factor (PF) | 0.8 | ||||||||||
| overload capacity | 110%, 3 minutes, 150%, 10 seconds | ||||||||||
| Peak Factor (CF) | 3:1 | ||||||||||
| Inverter efficiency | 90% | ||||||||||
| work make, do, create, compose, write, etc. ring realm |
Insulation strength (input and output) | 1500VAC, 1 minute | |||||||||
| Noise (1 meter) | ≤50dB | ||||||||||
| Environmental temperature for use | -10℃~+50℃ | ||||||||||
| humidity | 0~90%, no condensation | ||||||||||
| Using altitude (m) | ≤2000 | ||||||||||
| indicator light | Mains power, inverter, undervoltage, overcurrent, overheating | ||||||||||
| protection function | Input reverse protection, input undervoltage protection, output overload protection, output short circuit protection, overheating protection | ||||||||||
| Model (NHDA) | 10KVA-6003 | 20KVA-6003 | 30KVA-6003 | 50KVA-6003 | 80KVA-6003 | 100KVA-6003 | 150KVA-6003 | 200KVA-6003 | 300KVA-6003 | 400KVA-6003 | |
| 功率 (Kva) | 10 | 20 | 30 | 50 | 80 | 100 | 150 | 200 | 300 | 400 | |
| direct current Input |
Rated voltage (V)DC) | 600 | |||||||||
| Input voltage (V)DC) | 400-800 | ||||||||||
| communication output | Output rated voltage and frequency | 380VAC,50Hz | |||||||||
| Output voltage accuracy (V) | 380±2% | ||||||||||
| Output frequency accuracy (Hz) | 50±0.05% | ||||||||||
| Waveform Distortion Rate (THD) (Linear load) |
≤3% | ||||||||||
| dynamic response time (Load 0 ← → 100%) |
5% | ||||||||||
| Power factor (PF) | 0.8 | ||||||||||
| overload capacity | 110%, 3 minutes, 150%, 10 seconds | ||||||||||
| Peak Factor (CF) | 3:1 | ||||||||||
| Inverter efficiency | 90% | ||||||||||
| work make, do, create, compose, write, etc. ring realm |
Insulation strength (input and output) | 1500VAC, 1 minute | |||||||||
| Noise (1 meter) | ≤50dB | ||||||||||
| Environmental temperature for use | -10℃~+50℃ | ||||||||||
| humidity | 0~90%, no condensation | ||||||||||
| Using altitude (m) | ≤2000 | ||||||||||
| indicator light | Mains power, inverter, undervoltage, overcurrent, overheating | ||||||||||
| protection function | Input reverse protection, input undervoltage protection, output overload protection, output short circuit protection, overheating protection | ||||||||||