Welcome Customer !

Membership

Help

Wuhan Shengnuo Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Wuhan Shengnuo Instrument Technology Co., Ltd

  • E-mail

    info@snilaser.com

  • Phone

    13986279543

  • Address

    No. 28, Fozuling 3rd Road, Donghu New Technology Development Zone, Wuhan City

Contact Now

In situ laser HF gas analyzer can be customized for full tracking service

NegotiableUpdate on 04/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The in-situ laser HF gas analyzer can be customized for full process tracking services. The gas analyzer has the characteristics of high sensitivity, fast response speed, no background gas interference, non-contact optical measurement, etc. It can be applied to gas emission monitoring, process control and other scenarios in many industrial fields, providing reliable guarantee for real-time and accurate reflection of gas concentration changes.
Product Details

In situ laser HF gas analyzer can be customized for full tracking service

原位激光HF气体分析仪可定制全程跟踪服务

原位激光HF气体分析仪可定制全程跟踪服务

原位激光HF气体分析仪可定制全程跟踪服务

Product Introduction:

Advantages of in-situ measurement method

Direct analysis of process gases without any changes in sampling loss

Measure the average concentration of pipeline cross-section, which is closer to the real working conditions

• Fast real-time response, providing real gas concentration changes

Non contact optical measurement, suitable for high temperature, high pressure, and high dust conditions

• Customizable development for measurement processes


  Typical applications of in-situ measurement

• Blast furnace gas safety monitoring

Converter gas recovery

• Hot blast stove flue gas monitoring

Optimization of combustion in heating furnace

• Analysis of oxygen content in reaction kettle


performance parameters
model iLAS-700-O2 iLAS-700-CO iLAS-700-CO2 iLAS-700-CH4
form In situ injection In situ injection In situ injection In situ injection
gas O2 CO CO2 CH4
Measurement low limit 0.01% 0.01% 0.01% 0.01%
maximum range 0-99.99% 0-99.99% 0-99.99% 0-99.99%

Functional Parameters
power supply AC220V/DC24V Analog input 2-channel 4-20mA analog output 2-channel 4-20mA, maximum load 750 Ω
operating interface Magnetic control graphic interaction relay output 3 channels (24V/1A) digital output RS485, Support MODBUS RTU protocol

environmental parameters
optical path ≤15m Sample gas temperature ≤800℃ Sample gas pressure Atmospheric pressure ± 5kPa
ambient temperature -30-55℃ Sample humidity No condensation water ambient humidity ≤90%RH
Explosion-proof rating ExdⅡ CT6 Protection level IP66 purge gas 0.4-0.6MPa, Nitrogen source

  Note:1. Can provide H2O、C2H6、 Customization of special gases such as HCL, HF, HCN, etc;2. Customizable range according to application requirements;3. The actual optical path length is designed based on the installation pipe diameter size conditions

In situ laser HF gas analyzer can be customized for full tracking service


原位激光HF气体分析仪可定制全程跟踪服务