E-mail
info@snilaser.com
-
Phone
13986279543
-
Address
No. 28, Fozuling 3rd Road, Donghu New Technology Development Zone, Wuhan City
Wuhan Shengnuo Instrument Technology Co., Ltd
info@snilaser.com
13986279543
No. 28, Fozuling 3rd Road, Donghu New Technology Development Zone, Wuhan City
Manufacturers produce online monitoring and analysis instruments for ammonia escape in the metallurgical industry

Product Introduction:

Product Features
Heliot light cell structure, precise measurement
In situ measurement to solve the problem of sampling loss
High temperature throughout the process, solving the problem of ammonium salt crystallization
• Integrated body, compact structure, easy installation and maintenance
•Integrated oxygen concentration and humidity measurement, providing dry basis standard condition values
Typical Applications
•Chemical production process control
•CEMS ammonia emission monitoring
•Garbage incineration power generation
•Ammonia storage and pipeline concentration monitoring
•SCR/SNCR Denitrification Process Control
•Ultra low emissions in the cement industry
| performance parameters | |||||
| model | gas | Detection range | resolution | response time | drift |
| eLAS-100T | NH3 | 0-10mg/m3 | 0.01mg/m3 | ≤10s | ≤1%FS 7d |
| eLAS-200T | HCL | 0-100mg/m3 | 0.1mg/m3 | ≤10s | ≤1%FS 7d |
| eLAS-300T | HF | 0-5mg/m3 | 0.01mg/m3 | ≤10s | ≤1%FS 7d |
| Functional Parameters | |||||
| preheat | 30min | digital output | RS232/485 | analog output | 4-20mA maximum load 750 Ω |
| power supply |
AC100-240V 47-63Hz/1.5kVA |
alarm function |
Concentration over limit alarm, relay output alarm, laser temperature abnormalitycall the police
|
||
| environmental parameters | |||||
| Measure optical path length | 5-10m | Sample gas temperature | ≤800℃ | Sample gas pressure | Atmospheric pressure ± 5kPa |
| sampling flow | 2-3L/min | ambient temperature | -30-55℃ | sampling method | In situ extraction |
| Blow off gas source | 0.4-0.6MPa compressed air | Protection level | IP65 | ||
| Probe box size | 630(H)*230(W)*630(H)mm | weight | 45kg | ||
Manufacturers produce online monitoring and analysis instruments for ammonia escape in the metallurgical industry

Installation Diagram