Industrial high-pressure three blade Roots blowerProduct function
Oxygen supply core: providing oxygen for aerobic microorganisms in sewage treatment, accelerating organic matter degradation, and achieving sewage purification.
Mixing and stirring: By using airflow vortex to fully mix sewage with chemicals and returning sludge, the chemical treatment effect is improved.
Material transportation: Using high-pressure airflow to transport powdered or granular materials, reducing the risk of mechanical transportation blockage.
Process support: Provide stable gas sources in industrial production to assist in key process flows such as combustion, stirring, and cooling.
Industrial high-pressure three blade Roots blowerInstallation precautions
1. The foundation should be firm, the surface should be flat, and it should be 10-25cm higher than the ground.
2. There should be sufficient space around the fan to meet the needs of maintenance and disassembly.
3. The working environment temperature of the fan should not exceed 40 degrees Celsius. If it exceeds, measures should be taken to cool it down, otherwise the service life of the fan will be shortened.
4. When configuring the fan outdoors, please set up a rain shelter.
Installation of High Pressure Roots Blower - Precautions for Fan Pipe Installation
1. The fan ducts should be tightly connected and not leak air, and brackets should be installed at appropriate positions.
2. The pipeline material should be able to withstand exhaust temperature and pressure. (Try to use steel pipes as much as possible)
3. The interior of the pipeline should be clean and free of foreign objects to prevent debris from entering.
4. A one-way valve should be installed on the pipeline to prevent the backflow of high-pressure gas caused by fan reversal from entering the fan and causing damage to the fan. Attention: The one-way valve should be installed on a horizontal pipeline.
5. In the case of multiple wind turbines operating in parallel, gate valves must be installed on each branch pipeline (one of the turbines can be shut off during maintenance).
6. An exhaust valve should be installed on the pipeline to prevent the fan from starting under load. The fan should be started with no load before gradually closing the exhaust valve. When operating under load and shutting down, the exhaust valve should also be opened first to confirm that the fan is not under load before shutting down the fan.