Operating environment temperature |
-20 ℃~60 ℃ (electronic components) |
Operating environment humidity |
Non condensing 90% |
Operating environment vibration |
Maximum continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2) |
Operating environment electromagnetic field |
At 50 Hz, the highest value is 60 A/m (equivalent to a magnetic field of 50 AT in a 1 meter x 1 meter square electromagnetic coil) |
Protection of operating environment |
Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe |
Pipeline gas pressure |
-0.1-1MPa (up to 8MPa) |
Pipeline gas flow rate |
1m/s~30m/s |
Pipeline gas temperature |
Real time temperature: 200 ℃, instantaneous temperature: 260 ℃ (260 ℃ -800 ℃ can be customized) |
outer diameter of pipe |
0.1 meters to 4 meters |
Probe structure |
The standard probe is 16mm in diameter, with a length ranging from 100mm to 1000mm. The probe material is rare earth amorphous alloy, |
Dust particle size range |
The nominal range is 0.1 μ M to 200 μ M, and it can still receive signals outside the nominal range, but the signal characteristics are slightly different. |
Powder material |
Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter |
zero drift |
(Time) Less than 1% of the range per year. |
zero drift |
Within the specified temperature range, below 1% of the measuring range. |
Full-scale drift |
(Time) Less than 1% of range per year |
Full-scale drift |
Within the specified temperature range, below 1% of the measuring range. |
Line stability |
All components of the system are made of high stability electronic assemblies. |
Noise resistance |
All 50 or 60 Hz audio and harmonics are filtered out before the signal is received |
measurement range |
0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (customized for special ranges) |
Transmitter output mode |
Standard 4-20mA (two-wire system) (customizable switch quantity, RS485 communication, Modbus RTU protocol, HART protocol, etc.) |
Transmitter power supply |
24V (available within the range of 15V to 32V) |
measurement accuracy |
±1% |
Probe length selection |
Please select the probe length according to the formula, i.e. D/3 ≤ L ≤ 2D/3
(Among them: D - Inner diameter of pipeline, L - Probe length)
|
Explosion-proof marking |
Exia IIC T6 Ga/ExoD 21 T80 ℃ Certificate Number: CNV21.0092X
Ex db IIC T6 Gb, Ex tb IIC T80 ℃ Db Certificate Number: CNV24.1117X
|