Welcome Customer !

Membership

Help

Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd

  • E-mail

  • Phone

    13261731718

  • Address

    Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing

Contact Now

Madur GA-12plus Handheld Smoke Analyzer from Austria

NegotiableUpdate on 02/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The built-in pressure sensor of the Austrian Madur GA-12plus handheld flue gas analyzer is used for chimney suction measurement and continuous pump flow control. The Madur GA-12plus handheld smoke analyzer from Austria features an LCD display screen with backlight function.
Product Details

The built-in pressure sensor of the Austrian Madur GA-12plus handheld flue gas analyzer is used for chimney suction measurement and continuous pump flow control. The Madur GA-12plus handheld smoke analyzer from Austria features an LCD display screen with backlight function.


Madur GA-12plus Handheld Smoke Analyzer from AustriaMain features:

Equipped with 3 or 4 electrochemical sensors (standard configuration: O2, CO, NO/NOx, SO2).

*The analyzer works together with an external portable printer through wireless communication (IR LED).

*The built-in rechargeable lithium battery can work for up to 10 hours.

*A probe with a standard M30x1 device, suitable for all Madu gas probes with K-type or S-type thermocouples.

*Smoke and dust measurement can be carried out (suitable probe holder needs to be selected).

*The built-in pressure sensor is used for chimney suction measurement and continuous pump flow control.

*Optional second pressure sensor (differential pressure) - used to measure chimney suction force and flow rate (using pitot tube).

*Digital relative humidity and temperature probes can be used.

*Measurement of flue gas temperature and ambient temperature.

*LCD display screen (128x64) displays results with backlight function.

*Built in large memory for storing results.

*Calculate many additional parameters.

*Firmware for gas calibration.




Routine parameters of Madur GA-12plus handheld flue gas analyzer in Austria:

Version A (with separate pressure sensor)


Size (H x WxD)

243 x 130 x 60mm

257 x 130 x 60mm (with smoke interface)

Weight (only analyzer and 4 sensors, without accessories)

615g

Box material

ABS box, optional rubber protection feet

operation condition

10 ° C ÷ 50 ° C, relative humidity 5 ÷ 90% (non condensing)

storage temperature

-20°C ÷ +55°C

power supply

Built in Li ion rechargeable battery (1600mAh)

Operation time (fully charged battery)

Many 16 hours

Number of smoke sensors

3 or 4- see ordering guide

Result storage

64 Measurement Report

display

Graphic LCD128x64 with variable comparison and LED backlight function

Smoke pump

Diaphragm pump, large 0.6 ÷ 0.9 l/min

printer

External thermal IR printer MCP 8850 and charger

Communication interface with PC computer

RS-232C

Smoke filtration

Online filter inside the smoke probe tube


Version B (with additional two pressure sensors)


Size (H x WxD)

243 x 130 x 60mm

271 x 130 x 60mm (with smoke sensor)

Weight (only analyzer and 4 sensors, without accessories)

635g

All other data is the same as version A


Measurement of smoke composition

The following table displays all sensor/range combinations. Please note that there is a high possibility of three smoke sensors in one instrument - refer to the ordering guide


component

way

Range | Resolution

accuracy

Time (T90)

O2- Oxygen

O2-A2 electrochemical sensor

20.95% | 0.01%

± 0.1% of the measured value or 5% of the measured value

45 seconds

O2- Oxygen

O2-A2 electrochemical sensor

25.00% | 0.01%

± 0.1% of the measured value or 5% of the measured value

45 seconds

CO - Carbon monoxide

CO-AF electrochemical sensor

2 000ppm | 0.1ppm

± 5ppm for or 5% of the measured value

45 seconds

CO - Carbon monoxide

CO-AF electrochemical sensor

4000ppm | 1ppm

± 5ppm for or 5% of the measured value

45 seconds

CO - Carbon monoxide

CO-AF electrochemical sensor

20 000ppm | 1ppm

± 10ppm for or 5% of the measured value

45 seconds

CO - Carbon monoxide

CO-AE electrochemical sensor

10% (100 000ppm) | 10ppm

± 50ppm or 5% of the measured value

45 seconds

CO - Carbon monoxide

CO-AX electrochemical sensor and low H2 cross sensitivity

4 000ppm| 1ppm

± 5ppm for or 5% of the measured value

45 seconds

NO - Nitric oxide

NO-AE electrochemical sensor

2 000ppm | 0.1ppm

± 5ppm for or 5% of the measured value

45 seconds

NO2- Nitrogen dioxide

NO2-AE electrochemical sensor

1 000ppm | 0.1ppm

± 5ppm for or 5% of the measured value

45 seconds

SO2- Sulfur dioxide

SO2-AE electrochemical sensor

2 000ppm | 0.1ppm

± 5ppm for or 5% of the measured value

45 seconds

H2S - Hydrogen sulfide

H2S-AE electrochemical sensor

2 000ppm | 0.1ppm

± 5ppm for or 5% of the measured value

45 seconds


Other measurement/calculation results


variable

way

Range | Resolution

accuracy

Time (T90)

Tgas - flue gas temperature

K-type or S-type thermocouple

-10 ÷ 1000°C | 0.1°C

± 2°C

10 seconds

Tamb - Boiler input air temperature

Pt500 resistance sensor

-10 ÷ 100°C | 0.1°C

± 2°C

10 seconds

partial pressure

Silicon piezoresistive pressure sensor

-25hPa ÷ +25hPa | 0.1Pa (0.001hPa)

± 2Pa or 5% of the measured value

10 seconds

Smoke flow rate (optional)

Indirect, with pitot tube and second pressure sensor

1 ÷ 50m/s | 0.1m/s

0.3m/s or 5% of the measured value

10 seconds

RH - Relative humidity

SHT11 Capacitive Polymer Sensor (requires special probe)

5 ÷ 95% | 1%

± 5% for

30 seconds

Lambda λ - Excess smoke quantity

calculated

1 ÷ 10 | 0.01

± 5% of the measured value

10 seconds

QA - Chimney loss

calculated

0 ÷ 120% | 0.1%

± 5% of the measured value

10 seconds

Eta η - combustion efficiency

calculated

0 ÷ 100 | 0.1%

± 5% of the measured value

10 seconds