The built-in pressure sensor of the Austrian Madur GA-12plus handheld flue gas analyzer is used for chimney suction measurement and continuous pump flow control. The Madur GA-12plus handheld smoke analyzer from Austria features an LCD display screen with backlight function.
Madur GA-12plus Handheld Smoke Analyzer from AustriaMain features:
Equipped with 3 or 4 electrochemical sensors (standard configuration: O2, CO, NO/NOx, SO2).
*The analyzer works together with an external portable printer through wireless communication (IR LED).
*The built-in rechargeable lithium battery can work for up to 10 hours.
*A probe with a standard M30x1 device, suitable for all Madu gas probes with K-type or S-type thermocouples.
*Smoke and dust measurement can be carried out (suitable probe holder needs to be selected).
*The built-in pressure sensor is used for chimney suction measurement and continuous pump flow control.
*Optional second pressure sensor (differential pressure) - used to measure chimney suction force and flow rate (using pitot tube).
*Digital relative humidity and temperature probes can be used.
*Measurement of flue gas temperature and ambient temperature.
*LCD display screen (128x64) displays results with backlight function.
*Built in large memory for storing results.
*Calculate many additional parameters.
*Firmware for gas calibration.
Routine parameters of Madur GA-12plus handheld flue gas analyzer in Austria:
Version A (with separate pressure sensor)
Size (H x WxD) |
243 x 130 x 60mm 257 x 130 x 60mm (with smoke interface) |
Weight (only analyzer and 4 sensors, without accessories) |
615g |
Box material |
ABS box, optional rubber protection feet |
operation condition |
10 ° C ÷ 50 ° C, relative humidity 5 ÷ 90% (non condensing) |
storage temperature |
-20°C ÷ +55°C |
power supply |
Built in Li ion rechargeable battery (1600mAh) |
Operation time (fully charged battery) |
Many 16 hours |
Number of smoke sensors |
3 or 4- see ordering guide |
Result storage |
64 Measurement Report |
display |
Graphic LCD128x64 with variable comparison and LED backlight function |
Smoke pump |
Diaphragm pump, large 0.6 ÷ 0.9 l/min |
printer |
External thermal IR printer MCP 8850 and charger |
Communication interface with PC computer |
RS-232C |
Smoke filtration |
Online filter inside the smoke probe tube |
Version B (with additional two pressure sensors)
Size (H x WxD) |
243 x 130 x 60mm 271 x 130 x 60mm (with smoke sensor) |
Weight (only analyzer and 4 sensors, without accessories) |
635g |
All other data is the same as version A | |
Measurement of smoke composition
The following table displays all sensor/range combinations. Please note that there is a high possibility of three smoke sensors in one instrument - refer to the ordering guide
component |
way |
Range | Resolution |
accuracy |
Time (T90) |
O2- Oxygen |
O2-A2 electrochemical sensor |
20.95% | 0.01% |
± 0.1% of the measured value or 5% of the measured value |
45 seconds |
O2- Oxygen |
O2-A2 electrochemical sensor |
25.00% | 0.01% |
± 0.1% of the measured value or 5% of the measured value |
45 seconds |
CO - Carbon monoxide |
CO-AF electrochemical sensor |
2 000ppm | 0.1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
CO - Carbon monoxide |
CO-AF electrochemical sensor |
4000ppm | 1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
CO - Carbon monoxide |
CO-AF electrochemical sensor |
20 000ppm | 1ppm |
± 10ppm for or 5% of the measured value |
45 seconds |
CO - Carbon monoxide |
CO-AE electrochemical sensor |
10% (100 000ppm) | 10ppm |
± 50ppm or 5% of the measured value |
45 seconds |
CO - Carbon monoxide |
CO-AX electrochemical sensor and low H2 cross sensitivity |
4 000ppm| 1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
NO - Nitric oxide |
NO-AE electrochemical sensor |
2 000ppm | 0.1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
NO2- Nitrogen dioxide |
NO2-AE electrochemical sensor |
1 000ppm | 0.1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
SO2- Sulfur dioxide |
SO2-AE electrochemical sensor |
2 000ppm | 0.1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
H2S - Hydrogen sulfide |
H2S-AE electrochemical sensor |
2 000ppm | 0.1ppm |
± 5ppm for or 5% of the measured value |
45 seconds |
Other measurement/calculation results
variable |
way |
Range | Resolution |
accuracy |
Time (T90) |
Tgas - flue gas temperature |
K-type or S-type thermocouple |
-10 ÷ 1000°C | 0.1°C |
± 2°C |
10 seconds |
Tamb - Boiler input air temperature |
Pt500 resistance sensor |
-10 ÷ 100°C | 0.1°C |
± 2°C |
10 seconds |
partial pressure |
Silicon piezoresistive pressure sensor |
-25hPa ÷ +25hPa | 0.1Pa (0.001hPa) |
± 2Pa or 5% of the measured value |
10 seconds |
Smoke flow rate (optional) |
Indirect, with pitot tube and second pressure sensor |
1 ÷ 50m/s | 0.1m/s |
0.3m/s or 5% of the measured value |
10 seconds |
RH - Relative humidity |
SHT11 Capacitive Polymer Sensor (requires special probe) |
5 ÷ 95% | 1% |
± 5% for |
30 seconds |
Lambda λ - Excess smoke quantity |
calculated |
1 ÷ 10 | 0.01 |
± 5% of the measured value |
10 seconds |
QA - Chimney loss |
calculated |
0 ÷ 120% | 0.1% |
± 5% of the measured value |
10 seconds |
Eta η - combustion efficiency |
calculated |
0 ÷ 100 | 0.1% |
± 5% of the measured value |
10 seconds |