Welcome Customer !

Membership

Help

Anhui Zhongyi Electric Heating Materials Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Anhui Zhongyi Electric Heating Materials Co., Ltd

  • E-mail

    330909017@QQ.com

  • Phone

    13365509966

  • Address

    Tongcheng Town Industrial Park, Tianchang City, Chuzhou City, Anhui Province

Contact Now

Medium temperature self limiting electric heating belt

NegotiableUpdate on 04/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Summary: This product, "Medium Temperature Self Limiting Electric Heating Belt," is provided by a professional electric heating belt manufacturer. Zhongyi Electric Heating has rich experience in the installation and design of electric heating belts. The following are the types of "Medium Temperature Self Limiting Electric Heating Belt" models. Product introduction: Medium Temperature Self Limiting Electric Heating Belt (temperature control heating cable, self temperature regulating electric heating belt) is widely used in industrial enterprises such as power, petroleum, chemical, fire protection, natural gas, medicine, food, construction, etc., for pipeline and tank heat tracing, insulation and anticoagulation, anti freezing floor heating, and gutter heating
Product Details

Abstract: This product, "Medium Temperature Self Limiting Electric Heating Belt", is provided by a professional electric heating belt manufacturer. Zhongyi Electric Heating has rich experience in the installation and design of electric heating belts. The following is a product introduction of the "Medium Temperature Self Limiting Electric Heating Belt" model type: Medium Temperature Self Limiting Electric Heating Belt (temperature control heating cable, self temperature regulating electric heating belt) is widely used in industrial enterprises such as power, petroleum, chemical, fire protection, natural gas, medicine, food, construction, etc. for pipeline and tank heat tracing, insulation and anticoagulation, antifreeze floor heating, and gutter.

Zhongyi is a high-quality manufacturer of price models for medium temperature self limiting electric heating belts. Medium temperature self limiting electric heating strips (temperature control heating cables, self regulating electric heating strips) are widely used in industrial enterprises such as power, petroleum, chemical, fire protection, natural gas, medicine, food, and construction for pipeline and storage tank heat tracing, anti freezing floor heating, and gutter snow melting. This cable is suitable for ordinary areas, hazardous areas, and corrosive areas.

Introduction to Medium Temperature Self Limiting Electric Tracing Belt Products
中温自限温电热带
ZXW/ZBR/ZKW/ZBW/ZWK/ZHR/DZ/HV/ZKWZ corresponds to the foreign models Ruikan QTVR and Saimeng RBX series. The medium temperature self limiting electric heating belt (also known as the self controlled temperature electric heating belt, self regulating heating cable) is widely used for heat insulation, anticoagulation, and antifreeze of pipelines and storage tanks in industrial enterprises such as petroleum, chemical, steel, and power. This cable is suitable for ordinary areas, hazardous areas, and corrosive areas
Medium temperature self limiting electric heating belt product model
Product model: ZBR-J ZBR-B ZBR-P ZBR-F ZBR-PB
Medium temperature type: ZBR (ZXW/ZBR/ZKW/ZBW/ZWK/ZHR/DZ/HV/ZKWZ corresponds to foreign models Ruikan QTVR and Saimeng RBX series)

Medium temperature self limiting electric heating cable structure:

1. Copper core wire

2. Conductive plastic layer

3. Polyolefin insulation layer

4. Tin plated copper wire shielding layer

5. Fluoroplastic sheath

Technical indicators for medium temperature self limiting electric heating belt:

1. Standard color:

Brown, red, black

2. Temperature range:

Maintain a temperature of 105 ℃

Surface temperature 105 ℃± 5 ℃

Temperature tolerance: Modified polyolefin 105 ℃, flame retardant polyolefin 135 ℃
Fluorinated polyolefin at 180 ℃, perfluorinated material at 205 ℃

3. Thermal stability:

After cycling back and forth 300 times between 10 ℃ and 99 ℃,
The heating capacity of the electric heating belt is maintained at over 90%

4. Bending radius:

25.4mm at room temperature of 20 ℃; 35.0mm at low temperature of -30 ℃

5. Insulation resistance:

When the cable length is 100m and the ambient temperature is 75 ℃, use 2500VDC
Shake the meter for 1 minute, and the minimum insulation resistance (between the conductor and shield) is 3000M Ω

Working voltage:

12V 24V 36V 110V 220V 380V

10 ℃ output power:

25W/m 35W/m 45W/m 55W/m 65W/m 75W/m

Explosion proof mark:

Exe Ⅱ T 4

Explosion proof certificate:

National certificate:

Product advantages:
1. The temperature of the heat tracing pipeline is uniform, will not overheat, and is safe and reliable;
2. Save electricity;
3. During intermittent operation, the temperature rise starts quickly;
4. Low installation and operation costs;
5. Easy installation and maintenance;
6. Easy to automate management;
7. No environmental pollution;
8. Suitable for complex pipeline heat tracing;
9. Suitable for pipeline heating far away from the device;