Metal tube float flowmeter LZZ-50/RR1/M9/B1/Y

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The measuring component of the metal tube float flowmeter LZZ-50/RR1/M9/B1/Y consists of a conical measuring tube and a float. The float can freely move up and down in the conical measuring tube, changing the flow area in the pipeline. As the flow rate changes, the vertical position of the float in the measuring tube also changes accordingly. The position of the float is transmitted to the dial of the indicator through a magnetic transmission system through a steel tube, indicating the size of the flow value.
Product Details

Metal tube float flowmeter LZZ-50/RR1/M9/B1/YIt is a commonly used variable area flow measurement instrument in industrial automation process control. It has the characteristics of small size, large detection range, and easy use. It can be used to measure the flow rate of liquids and gases, especially suitable for measuring the flow rate of low velocity and small flow media

Metal tube float flowmeter LZZ-50/RR1/M9/B1/YMeasurement section features:
1. Sturdy all metal structure design float flowmeter
2. Measurement tube indicator designed with independent concept
3. Stainless steel, Hastelloy, titanium, PTFE material measurement systems can be selected
4. Low pressure loss design
5. Short stroke, small structural design, total instrument height of 250
6. Magnetic coupling structure ensures data transmission and signal stability
7. Insulation or heat tracing jacket
8. Vertical, horizontal, and various installation methods are more suitable for different usage scenarios
9. Suitable for flow measurement of small caliber and low velocity media
10. Reliable work, minimal maintenance, and long lifespan
12. Wide traffic ratio 10:1
11. Not high requirements for straight pipe sections
13. Dual row large LCD display, optional on-site instantaneous/cumulative flow display, can be equipped with backlight
14. Single axis sensitive indication
15. Non contact magnetic coupling transmission
16. All metal structure, suitable for high temperature, high pressure, and highly corrosive media
17. Can be used in flammable and explosive hazardous environments
18. Choose a two-wire system, battery, and AC power supply method
19. Multi parameter calibration function
20. Equipped with data recovery, data backup, and power down protection functions

flow parameters

Tongjing (mm)

flow range

Pressure loss kPa

Water L/h*

Air M3/h*

water

air

Conventional type

corrosion-resistant type

Conventional type, anti-corrosion type

15

2.5~25

---

0.07~0.7

6.5

7.1

4.0~40

2.5~25

0.11~1.1

6.5

7.2

6.3~63

4.0~40

0.18~1.8

6.6

7.3

10~100

6.3~63

0.28~2.8

6.6

7.5

16~160

10~100

0.40~4.0

6.8

8.0

25~250

16~160

0.7~7.0

7.2

10.8

40~400

25~250

1.0~10

8.6

10.0

63~630

40~400

1.6~16.0

11.1

14.0

25

100~1000

63~630

3~30

7.0

7.7

160~1600

100~1000

4.5~45

8.0

8.8

250~2500

160~1600

7~70

10.8

12.0

400~4000

250~2500

11~110

15.8

19.0

40

500~5000

---

12~120

10.8

9.8

600~6000

----

16~160

12.6

16.5

50

630~6300

400~4000

18~180

8.1

8.6

1000~10000

630~6300

25~250

11.0

10.4

1600~16000

1000~10000

40~400

17.0

15.5

80

2500~25000

1600~16000

60~600

8.1

12.9

4000~40000

2500~25000

80~800

9.5

18.5

100

6300~63000

4000~40000

100~1000

15.0

19.2

150

20000~100000

---

600~3000

19.2

20.3

Installation precautions
In order to ensure the normal operation and measurement accuracy of the metal tube float flowmeter, the following points should be noted when installing the flowmeter:
·The metal tube float flowmeter must be installed vertically on a vibration free pipeline. The fluid flows through the flowmeter from bottom to top, and the verticality is better than 2 °. When installed horizontally, the horizontal angle is better than 2 °;
·For the convenience of maintenance, replacement of flow meters, and cleaning of measuring pipelines, metal tube float flow meters installed on process pipelines should be equipped with bypass pipelines and bypass valves;
·The inlet of the metal tube float flowmeter should have a straight pipe section of at least 5 times the diameter of the pipe, and the outlet should have a straight pipe section of 250mm;
·If the medium contains ferromagnetic substances, a magnetic filter should be installed; If the medium contains solid impurities, it should be considered to install a filter between the valve and the straight pipe section;
·When used for gas measurement, it should be ensured that the pipeline pressure is not less than 5 times the pressure loss of the flowmeter to ensure stable operation of the float;
·In order to avoid deformation of the flow meter caused by the pipeline, the flange of the process pipeline must be coaxial and parallel to the flange of the flow meter. The pipeline support should be used to avoid pipeline vibration and reduce the axial load of the flow meter. The control valve in the measurement system should be installed downstream of the flow meter:
·When measuring gas, if the gas is directly discharged into the atmosphere at the outlet of the flowmeter, a valve should be installed at the outlet of the instrument, otherwise a pressure drop will occur at the float, causing data distortion.
·When installing instruments with PTFE lining, do not tighten the flange nuts asymmetrically at will to avoid deformation of the PTEF lining;
·Instruments with LCD displays should avoid direct sunlight on the display as much as possible to avoid reducing the lifespan of the LCD; Instruments powered by lithium batteries should avoid direct sunlight and high temperature environments (≥ 65 ℃) as much as possible to avoid reducing the capacity and lifespan of the lithium battery.