The multi-channel dust online monitoring system is an integrated structure, and the measuring electrodes are made of imported protective materials, which improves the ability to withstand high temperatures, corrosion, and adhesion, reduces cleaning and maintenance, extends the service life, and improves product quality.
Multi channel dust online monitoring systemIt is one of the important equipment to ensure the safe and environmentally friendly operation of dust removal equipment systems. It can integrate operation, display, alarm, and system operation status traceability, achieve real-time online monitoring of dust concentration in the clean air chamber of the dust collector, prevent dust concentration exceeding the standard due to factors such as bag dropping and leakage during operation, eliminate hidden dangers, improve equipment safety guarantee, timely, continuously, and accurately reflect equipment operation status, avoid safety accidents, and reduce equipment accident rate.
Product Features
1. The system has high sensitivity and good linearity for dust detection. Dust contamination of the probe does not affect the measurement sensitivity, and it is maintenance free and requires no cleaning.
2. Standard two-wire 4-20mA current output (other output methods can be customized), strong anti-interference ability, easy long-distance signal transmission, no special requirements for signal transmission wires, linear relationship between output current and dust concentration, convenient for subsequent PLC data processing.
3. The integrated transmitter output 4-20mA current in the junction box is electrically isolated from the dust sensing probe to achieve safe signal transmission.
4. The product has an integrated structure, and the measuring electrodes are made of imported protective materials, which improves the ability to withstand high temperatures, corrosion, and adhesion, reduces cleaning and maintenance, extends the service life, and improves product quality.
Multi channel dust online monitoring systemtechnical specifications
Operating environment temperature |
-20 ℃~60 ℃ (electronic components) |
Operating environment humidity |
Non condensing 90% |
Operating environment vibration |
Maximum continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2) |
Operating environment electromagnetic field |
At 50 Hz, the highest value is 60 A/m (equivalent to a magnetic field of 50 AT in a 1 meter x 1 meter square electromagnetic coil) |
Protection of operating environment |
Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe |
Pipeline gas pressure |
-0.1-1MPa (up to 8MPa) |
Pipeline gas flow rate |
1m/s~30m/s |
Pipeline gas temperature |
Real time temperature: 200 ℃, instantaneous temperature: 260 ℃ (260 ℃ -800 ℃ can be customized) |
outer diameter of pipe |
0.1 meters to 4 meters |
Probe structure |
The standard probe is 16mm in diameter, with a length ranging from 100mm to 1000mm. The probe material is rare earth amorphous alloy, |
Dust particle size range |
The nominal range is 0.1 μ M to 200 μ M, and it can still receive signals outside the nominal range, but the signal characteristics are slightly different. |
Powder material |
Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter |
zero drift |
(Time) Less than 1% of the range per year. |
zero drift |
Within the specified temperature range, below 1% of the measuring range. |
Full-scale drift |
(Time) Less than 1% of range per year |
Full-scale drift |
Within the specified temperature range, below 1% of the measuring range. |
Line stability |
All components of the system are made of high stability electronic assemblies. |
Noise resistance |
All 50 or 60 Hz audio and harmonics are filtered out before the signal is received |
measurement range |
0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (customized for special ranges) |
Transmitter output mode |
Standard 4-20mA (two-wire system) (customizable switch quantity, RS485 communication, Modbus RTU protocol, HART protocol, etc.) |
Transmitter power supply |
24V (available within the range of 15V to 32V) |
measurement accuracy |
±1% |
Probe length selection |
Please select the probe length according to the formula, i.e. D/3 ≤ L ≤ 2D/3
(Among them: D - Inner diameter of pipeline, L - Probe length)
|
Explosion-proof marking |
Exia IIC T6 Ga/ExoD 21 T80 ℃ Certificate Number: CNV21.0092X
Ex db IIC T6 Gb, Ex tb IIC T80 ℃ Db Certificate Number: CNV24.1117X
|
The above parameters meet the requirements of relevant national standards. Due to product upgrades or discrepancies between pictures and actual machines, please refer to the actual machine.