ProfiNet protocol multi cycle absolute value encoder SASM58
Features and Applications:
¨ International StandardProfiNet/IOagreement
¨ Detachable modular bus adapter with arbitrary address settings for easier connection
¨ European standard installation size, shaft type installation or blind hole type installation, terminal wiring is more convenient for installation
¨ Protection level up toIP68, The working temperature can reach -40 ° C...+85 ° C, making it perfect for long-term underwater work
¨ Featuring a safety lock type bearing design, it can prevent large-sized high-quality bearing assemblies from misalignment during operation and installation due to large axial loads.
¨ Stainless steel explosion-proof heavy-duty encoder can be selected, withEX II 2 G Ex ib IIB T4 Gb EU Explosion proof Rating Certification To safeguard the petrochemical industry and explosion-proof equipment

Product Series |
SASM58J |
SASM58T |
SASM58H |
Size (shell) |
Ø 58mm |
feature |
Axial belt clamping flange |
Axial belt synchronous flange |
Tightening ring blind hole type |
Spindle size |
Shaft type Ø 6, 8, 10, 12, 14, 15mm |
Shaft type Ø 6, 8, 10mm |
Blind hole type Ø 6, 8, 10, 12, 14, 15mm |
|
output signal |
ProfiNet/IO |
Output driver |
Ethernet |
transmission rate |
10 / 100 Mbit |
Interface cycle time |
≥ 1 ms |
power supply voltage |
10... 30VDC (reverse polarity protection, overvoltage protection) |
Single cycle resolution |
Standard 13 bit 8192, maximum 16 bit 65536 |
number of turns |
4096 turns |
encoding |
Binary code |
repeatability accuracy |
±2BIT |
current consumption |
<50mA (24V power supply)no-load |
Programmable parameters |
Each circle corresponds to an adjustable value, software limit switch, rotation direction, preset value, rate output, rate time base, baud rate |
maximum speed |
6000r/min |
Spindle load |
Radial 110N, axial 40N |
Protection level |
IP65 or IP66 |
Starting torque |
≤3Ncm |
Operating Temperature |
-40°C....85°C(Customizable working temperature)-40°C....85°C) |
Storage temperature |
-40°C. ...100°C |
impact-resistant |
1000m/s2 , 6ms(100g) |
Anti vibration |
20g |
connection method |
Three connectors are one eachM12, Male 4-pin size A and two M12, male, 4-pin, size 2 |
LED indicator light:
Power light: green light indicates a fault, dark light indicates no power supply |
Configuration light: If the red light is on, it indicates a fault; if it is dark, it indicates a normal configuration |
Bus interface 1/2: Green/orange light indicates normal operation, dark indicates abnormal operation |