BN-HWTWOutdoor high and low temperature imaging human body temperature measuring instrument


Product Features:
High sensitivity infrared cameraHigh definition visible light camera
High performance embedded motherboard
Camera+embedded motherboard+black body integrated structure, no need to configure a computer, can be directly connected to a monitor through HDMI for display and various operations
Artificial intelligence temperature measurement and detection systemThe product integrates high-sensitivity infrared camera, high-definition visible light camera, high-precision blackbody, high-performance temperature measurement engine, non-medical, artificial intelligence driven, automatic alarm, visualization platform, and high-precision thermal imaging detection system.
BN-HWTW is based on artificial intelligence algorithms and infrared thermal imaging temperature measurement technology, which can quickly identify and alert individuals with fever symptoms in the population, and accurately display temperature values. This device is widely used in large public places such as airports, stations, schools, hospitals, factories, and shopping malls.
The system has automatic facial recognition and capture capabilities, and can quickly detect forehead thermal temperature in milliseconds with an accuracy of 0.3 ℃. At the same time, BN-HWTW has an automatic temperature algorithm based on artificial intelligence technology, which does not require on-site manual intervention and can accurately identify and quickly analyze the temperature of individual personnel.
rapid detection
It can measure and detect a large number of people within 0.05 seconds.
High sensitivityThe temperature resolution of the instrument can reach ± 0.3 ° C, suitable for long-distance measurement of large flow rates and large areas.
Non sensory measurementMeasurement can be carried out without knowing the object being measured.
user experienceThe system has strong operability, flexibility, scientificity, and multi platform control and display.
Outdoor high and low temperature imaging human body temperature measuring instrument
Product Specifications
resolution |
2 million pixels |
Imaging devices |
CMOS |
illuminance |
0.01Lux (color mode) -0.001Lux (black and white mode) |
signal-to-noise ratio |
>56dB |
voltage |
5V connection |
infrared camera | |
detector type |
Uncooled infrared array sensor |
resolution |
160 * 120 output (384 * 288) |
Pixel spacing |
17um |
Working band |
8~14 um |
Detector NETD |
≤60mK (F/1,300K, 50Hz) |
frame rate |
15 Hz |
Temperature measurement data output |
Full range temperature output |
Temperature measurement range |
20℃~50℃ |
Field of view angle (calculated value) |
40° × 30° |
Number of people detected per minute |
150-200 people |
boldface | |
Effective radiation area |
20mm*30mm |
Surface emissivity |
0.96 ±0.02 |
temperature range |
(Environmental temperature+5 ° C)~(50 ° C) |
temperature resolution |
0.01°C |
stable accuracy |
Better than ± 0.1 ° C |
warm-up time |
<2 minutes |
Main board parameters | |
SOC |
Broadcom BCM2711 |
CPU |
64 bit 1.5GHz quad core (28nm process) |
GPU |
Broadcom VIdeoCore VI@500Hz |
Bluetooth |
Bluetooth 5.0 |
USB interface |
USB interface 2.0 * 2/USB interface 3.0 * 2 |
HDMI |
Micro HDMI * 2 supports 4K60 |
power supply |
TYpe C(%V 3A) |
network |
Wifi 802.11AC, Gigabit Ethernet |
multimedia |
H.265(4Kp60 decode); H.264(1080p60 decode,1080p30 encode); OpenGl es,3.0 graphics); |
Other parameters | |
IR-CUT automatic switching, backlight compensation, strong light suppression, automatic white balance | |
Operating Temperature |
0℃~40℃ |
Installation environment |
Indoor or outdoor |
Installation method |
Bracket, wall mounted, lifting |
Product dimensions |
|
Blackbody thermal imaging integrated thermometer
Operation Manual
Safety precautions:
1) Please do not touch the lens to prevent it from being damaged or dirty.
2) Please be careful to prevent the lens from being worn, scratched, or even torn.
3) Install the equipment in an environment with waterproof and lightning protection measures.
4) Due to the use of highly sensitive thermal sensors in uncooled infrared thermal imagers, the lens should not be directly aimed at strong radiation sources (such as the sun, direct or reflected laser beams, etc.) under any circumstances (power on or off), otherwise it will cause damage to the uncooled infrared thermal imager.
5) This product is a precision electronic instrument equipment, so please handle it carefully during use, storage, and transportation to prevent dangerous actions such as external force impact or falling from a height.
6) During transportation and storage, the ambient temperature is not allowed to be lower than -25 ℃; Original packaging boxes must be used during transportation.
7) Before turning on the device, please ensure that it is an original power adapter and connected correctly. If the power connection is incorrect, it may cause equipment damage.
8) If the device is running abnormally, do not dismantle it by yourself.