E-mail
2019288892@qq.com
-
Phone
15801211415
-
Address
No.1 Beiqing Road, Changping District, Beijing
Beijing Bonn Instrument Measurement and Control Technology Co., Ltd
2019288892@qq.com
15801211415
No.1 Beiqing Road, Changping District, Beijing
The BN-WDC6810 series products are developed by Bonn Instrument Company based on years of experience in developing meteorological and environmental monitoring products and the actual situation on site. This series of products can collect temperature, humidity, air pressure, wind speed, wind direction, rainfall, radiation, illumination, ultraviolet radiation PM2.5、PM10、CO、SO2、NO2、CO2、O3、 Noise and other parameters, high product integration, high aesthetic value, no installation, no wiring, can replace traditional pieced together small-scale automatic meteorological environment observation,Ultrasonic six element micro meteorological station manufacturer.
1、 Product Introduction
Ultrasonic six element micro meteorological station manufacturer
1.1 Overview
The BN-WDC6810 series products are developed by Bonn Instrument Company based on years of experience in developing meteorological and environmental monitoring products and the actual situation on site. This series of products can collect temperature, humidity, air pressure, wind speed, wind direction, rainfall, radiation, illumination, ultraviolet radiation PM2.5、PM10、CO、SO2、NO2、CO2、O3、 Noise and other parameters, high product integration, high appearance, no installation, no wiring, can replace traditional pieced together small automatic meteorological environment observation stations.
1.2 Product Features
*Real time measurement using sensing technology
*It can work all day without being affected by rainstorm, snow, ice and frost
*High measurement accuracy and stable performance
*Compact and aesthetically pleasing structure
*High integration, easy installation and disassembly
*Maintenance free, no need for on-site calibration
*Using ASA engineering plastics for outdoor applications, the color remains unchanged year-round
1.3 Application Fields
*Meteorological monitoring
*Urban environmental monitoring
*Wind power generation
*Maritime vessels
*airport
*Bridge Tunnel
2、 Product parameters
2.1 BN-W D C 6812-6817 Micro Meteorological Instrument Series Selection Table
Production of Ultrasonic Six Element Micro Meteorological Station*
2.2
BN-W D C 6817-6820 Micro Meteorological Instrument Series Selection Table
|
model
parameter |
6812 |
6815 |
6816 |
6817 |
6817A |
|
air temperature |
|
√ |
√ |
√ |
√ |
|
air humidity |
|
√ |
√ |
√ |
√ |
|
atmospheric pressure |
|
√ |
√ |
√ |
√ |
|
wind speed |
√ |
√ |
√ |
√ |
√ |
|
wind direction |
√ |
√ |
√ |
√ |
√ |
|
rainfall |
|
|
√ |
√ |
√ |
|
illuminance |
|
|
|
√ |
|
|
solar radiation |
|
|
|
|
√ (Optoelectronics) |
|
model parameter |
6817B |
6818 |
6818B |
6818C |
6818E |
6820 |
PM2.5 |
√ |
√ |
√ |
√ |
√ |
√ |
PM10 |
√ |
√ |
√ |
√ |
√ |
√ |
carbon monoxide |
|
√ |
|
|
|
√ |
sulfur dioxide |
|
√ |
|
|
|
√ |
nitrogen dioxide |
|
√ |
|
|
|
√ |
ozone |
|
√ |
|
|
|
√ |
air temperature |
√ |
√ |
√ |
√ |
√ |
√ |
air humidity |
√ |
√ |
√ |
√ |
√ |
√ |
atmospheric pressure |
√ |
|
√ |
√ |
√ |
√ |
wind speed |
√ |
|
√ |
√ |
√ |
√ |
wind direction |
√ |
|
√ |
√ |
√ |
√ |
rainfall |
|
|
√ |
√ |
√ |
√ |
illuminance |
|
|
|
√ |
|
|
solar radiation |
|
|
√ (Thermoelectric) |
|
|
|
noise |
√ |
|
|
|
√ |
|
ultraviolet |
|
|
|
|
√ |
|
B N -CPM2510、 2512, 2516 Air Quality Transmitter Selection Table
|
model
parameter |
CPM2510 |
CPM2512 |
CMP2516 |
|
air temperature |
|
√ |
√ |
|
air humidity |
|
√ |
√ |
|
illuminance |
|
|
√ |
|
noise |
|
|
√ |
|
PM2.5 |
√ |
√ |
√ |
|
PM10 |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.1 2.4 Technical parameter table
monitoring parameters |
range |
resolution |
accuracy |
configuration |
PM2.5 |
0-1000ug/m³ |
1ug/m³ |
± 10% (<500 micrograms) |
optional |
PM10 |
0-1000ug/m³ |
1ug/m³ |
± 10% (<500 micrograms) |
optional |
carbon monoxide |
0-20ppm |
≤10ppb |
±1.5%F.S |
optional |
sulfur dioxide |
0-2000ppb |
≤10ppb |
±1.5%F.S |
optional |
nitrogen dioxide |
0-2000ppb |
≤10ppb |
±1.5%F.S |
optional |
ozone |
0-2000ppb |
≤10ppb |
±1.5%F.S |
optional |
temperature |
-40-60℃ |
0.01℃ |
±0.3℃(25℃) |
optional |
relative humidity |
0-100RH |
0.01% |
±3%RH |
optional |
|
wind speed |
0-60m/s |
0.01m/s |
(0-30m/s)± 0.3m/s or ± 3% |
optional |
wind direction |
0-360° |
0.1° |
±2° |
optional |
atmospheric pressure |
300-1100hpa |
0.1hpa |
±0.5hpa(0-30℃) |
optional |
precipitation |
0-200mm/h |
0.1mm |
Error ± 10% |
optional |
illuminance |
0-100klux |
10lux |
3% |
optional |
|
Solar radiation (photoelectric) /Thermoelectric) |
0-2000W/M2 |
1W |
3% 5% |
optional |
noise |
30-130dB |
0.1dB |
±1.5dB |
optional |
ultraviolet |
0-15 |
/ |
/ |
optional |
carbon dioxide |
0-5000PPM |
1PPM |
± 40PPM ± 3% of the reading |
optional |
Manufacturer of Ultrasonic Six Element Micro Meteorological Station
\\\\



MODBUS RTU Communication Protocol
Baud rate: 9600 Data bits: 8
Stop bit: 1 Check bit: None
5.1 CRC Explanation:
In all the following instructions, the CRC16 two byte in the MODBUS RTU protocol follows MODBUS regulations: low byte comes first, high byte comes last.
In the following instructions, it is assumed that the sensor address is 0xFF (default sensor address is FF)
5.2 Return Error Code Regulations:
Sensors do not return error codes when receiving incorrect commands (including CRC16 validation errors). When the upper computer fails to receive return data after sending the instruction for 100ms, it may consider the instruction to have failed and resend the instruction.
5.3 Standard MODBUS Register Description
Special note: The number or length of registers in the MODBUS command is two bytes and 16 bits per unit (high byte first, low byte last), rather than a single byte and 8 bits per unit.
Users should ensure that the range of the address and quantity of registers in the command is within the specified range of this system. If it exceeds the range, the output result of the sensor will be unpredictable. Users should ensure that the MODBUS command meets the requirements of this manual in the upper computer software design
Input register: Read with function code 03
address |
operation |
content |
remark |
0x0001 |
read-only |
Noise, amplified by 10 times as a hexadecimal number, such as 0x021C, indicates that the noise is 54.0dB |
|
0x0002 |
read-only |
retain |
|
0x0003 |
read-only |
SO2 concentration, hexadecimal number, such as 0x0172 indicating SO2 concentration of 370ppb |
|
0x0004 |
read-only |
NO2 concentration, hexadecimal number, such as 0x0036 indicating a NO2 concentration of 54ppb |
|
0x0005 |
read-only |
CO concentration, hexadecimal number, such as 0x0A0 indicating a CO concentration of 2560ppb |
|
0x0006 |
read-only |
O3 concentration, hexadecimal number, such as 0x0123 indicating an O3 concentration of 291ppb |
|
0x0007 |
read-only |
PM2.5 concentration, hexadecimal number, such as 0x0172 indicating a PM2.5 concentration of 370ug/m ³ |
|
0x0008 |
read-only |
PM10 concentration, hexadecimal number, such as 0x0193 indicating a PM10 concentration of 403ug/m ³ |
|
|
0x0009 |
read-only |
The air temperature is represented by a hexadecimal number multiplied by 100 times by adding 40, such as 0x1B00 6912/100-40=29.12℃ |
|
0x000A |
read-only |
Air humidity, a hexadecimal number magnified 100 times, such as 0x1603 representing 5635/100=56.35% |
|
0x000B |
read-only |
Atmospheric pressure, a hexadecimal number magnified 10 times, such as 0x2784 representing 10116/10=1011.6hPa |
|
0x000C |
read-only |
Wind speed, a hexadecimal number magnified 100 times, such as 0x0125, represents 293/100=2.93m/s |
|
|
0x000D |
read-only |
Wind direction, a hexadecimal number magnified 10 times, such as 0x0C14 representing 3092/10=309.2 ° |
North for 0° |
|
0x000E |
read-only |
Rainfall, a hexadecimal number magnified 10 times, such as 0x0016 representing 2.2mm |
Default rainfall for 10 minutes |
0x000F |
read-only |
Radiation, hexadecimal number, such as 0x0172, represents a radiation intensity of 370W/㎡ |
|
0x0010 |
read-only |
Illumination, a hexadecimal number magnified 100 times, for example, 0x0123 represents an illumination intensity of 2.91.Klux |
|
0x0011 |
read-only |
UV index, hexadecimal number, such as 0x05 representing a UV index of 5 |
|
0x0012 |
read-only |
CO2, A hexadecimal number, such as 0x01F4, represents a CO2 concentration of 500ppm |
|
system parameters
Stability: less than 1% within the sensor's service life, response time: less than 10 seconds
Preheating time: 30 seconds (12 hours for SO2, NO2, CO, O3)
Working current: DC12V ≤ 60ma (HCD6815) - DC12V ≤ 180ma (HCD6820) Power consumption: DC12V ≤ 0.72W (HCD6815); DC12V≤2.16W(HCD6820)
Lifespan: Except for SO2, NO2, CO, O3, PM2.5, PM10 (normal environment 1 year, high pollution environment not guaranteed), the lifespan shall not be less than 3 years.
Output: RS485, MODBUS communication protocol Shell material: ASA engineering plastic
Working environment: temperature -30~70 ℃, working humidity: 0-100 ℃, storage conditions: -40~60 ℃
Standard cable length: 3 meters
Lead length: RS485 1000 meters Protection level: IP65