Welcome Customer !

Membership

Help

Beijing Bonn Instrument Measurement and Control Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Ultrasonic six element micro meteorological station manufacturer

NegotiableUpdate on 03/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The BN-WDC6810 series products are developed by Bonn Instrument Company based on years of experience in developing meteorological and environmental monitoring products and the actual situation on site. This series of products can collect temperature, humidity, air pressure, wind speed, wind direction, rainfall, radiation, illumination, ultraviolet radiation PM2.5、PM10、CO、SO2、NO2、CO2、O3、 Noise and other parameters, high product integration, high appearance, no installation, no wiring, can replace traditional pieced together small automatic meteorological environment observation, ultrasonic six element micro meteorological station manufacturer.
Product Details

The BN-WDC6810 series products are developed by Bonn Instrument Company based on years of experience in developing meteorological and environmental monitoring products and the actual situation on site. This series of products can collect temperature, humidity, air pressure, wind speed, wind direction, rainfall, radiation, illumination, ultraviolet radiation PM2.5、PM10、CO、SO2、NO2、CO2、O3、 Noise and other parameters, high product integration, high aesthetic value, no installation, no wiring, can replace traditional pieced together small-scale automatic meteorological environment observation,Ultrasonic six element micro meteorological station manufacturer.

1、 Product Introduction
Ultrasonic six element micro meteorological station manufacturer
1.1 Overview
The BN-WDC6810 series products are developed by Bonn Instrument Company based on years of experience in developing meteorological and environmental monitoring products and the actual situation on site. This series of products can collect temperature, humidity, air pressure, wind speed, wind direction, rainfall, radiation, illumination, ultraviolet radiation PM2.5、PM10、CO、SO2、NO2、CO2、O3、 Noise and other parameters, high product integration, high appearance, no installation, no wiring, can replace traditional pieced together small automatic meteorological environment observation stations.
1.2 Product Features
*Real time measurement using sensing technology
*It can work all day without being affected by rainstorm, snow, ice and frost
*High measurement accuracy and stable performance
*Compact and aesthetically pleasing structure
*High integration, easy installation and disassembly
*Maintenance free, no need for on-site calibration
*Using ASA engineering plastics for outdoor applications, the color remains unchanged year-round
1.3 Application Fields
*Meteorological monitoring
*Urban environmental monitoring
*Wind power generation
*Maritime vessels
*airport
*Bridge Tunnel

2、 Product parameters

2.1 BN-W D C 6812-6817 Micro Meteorological Instrument Series Selection Table

Production of Ultrasonic Six Element Micro Meteorological Station*

2.2
BN-W D C 6817-6820 Micro Meteorological Instrument Series Selection Table

model

parameter

6812

6815

6816

6817

6817A

air temperature

air humidity

atmospheric pressure

wind speed

wind direction

rainfall

illuminance

solar radiation

√ (Optoelectronics)

model

parameter

6817B

6818

6818B

6818C

6818E

6820

PM2.5

PM10

carbon monoxide

sulfur dioxide

nitrogen dioxide

ozone

air temperature

air humidity

atmospheric pressure

wind speed

wind direction

rainfall

illuminance

solar radiation

√ (Thermoelectric)

noise

ultraviolet


B N -CPM2510、 2512, 2516 Air Quality Transmitter Selection Table

model

parameter

CPM2510

CPM2512

CMP2516

air temperature

air humidity

illuminance

noise

PM2.5

PM10

2.1 2.4 Technical parameter table

monitoring parameters

range

resolution

accuracy

configuration

PM2.5

0-1000ug/m³

1ug/m³

± 10% (<500 micrograms)

optional

PM10

0-1000ug/m³

1ug/m³

± 10% (<500 micrograms)

optional

carbon monoxide

0-20ppm

≤10ppb

±1.5%F.S

optional

sulfur dioxide

0-2000ppb

≤10ppb

±1.5%F.S

optional

nitrogen dioxide

0-2000ppb

≤10ppb

±1.5%F.S

optional

ozone

0-2000ppb

≤10ppb

±1.5%F.S

optional

temperature

-40-60℃

0.01℃

±0.3℃(25℃)

optional

relative humidity

0-100RH

0.01%

±3%RH

optional

wind speed

0-60m/s

0.01m/s

(0-30m/s)±

0.3m/s or ± 3%

optional

wind direction

0-360°

0.1°

±2°

optional

atmospheric pressure

300-1100hpa

0.1hpa

±0.5hpa(0-30℃)

optional

precipitation

0-200mm/h

0.1mm

Error ± 10%

optional

illuminance

0-100klux

10lux

3%

optional

Solar radiation (photoelectric)

/Thermoelectric)

0-2000W/M2

1W

3%

5%

optional

noise

30-130dB

0.1dB

±1.5dB

optional

ultraviolet

0-15

/

/

optional

carbon dioxide

0-5000PPM

1PPM

± 40PPM ± 3% of the reading

optional

Manufacturer of Ultrasonic Six Element Micro Meteorological Station
\\\\

MODBUS RTU Communication Protocol

Baud rate: 9600 Data bits: 8
Stop bit: 1 Check bit: None
5.1 CRC Explanation:
In all the following instructions, the CRC16 two byte in the MODBUS RTU protocol follows MODBUS regulations: low byte comes first, high byte comes last.
In the following instructions, it is assumed that the sensor address is 0xFF (default sensor address is FF)

5.2 Return Error Code Regulations:
Sensors do not return error codes when receiving incorrect commands (including CRC16 validation errors). When the upper computer fails to receive return data after sending the instruction for 100ms, it may consider the instruction to have failed and resend the instruction.

5.3 Standard MODBUS Register Description
Special note: The number or length of registers in the MODBUS command is two bytes and 16 bits per unit (high byte first, low byte last), rather than a single byte and 8 bits per unit.


Users should ensure that the range of the address and quantity of registers in the command is within the specified range of this system. If it exceeds the range, the output result of the sensor will be unpredictable. Users should ensure that the MODBUS command meets the requirements of this manual in the upper computer software design

Input register: Read with function code 03

address

operation

content

remark

0x0001

read-only

Noise, amplified by 10 times as a hexadecimal number, such as 0x021C, indicates that the noise is 54.0dB

0x0002

read-only

retain

0x0003

read-only

SO2 concentration, hexadecimal number, such as 0x0172 indicating SO2 concentration of 370ppb

0x0004

read-only

NO2 concentration, hexadecimal number, such as 0x0036 indicating a NO2 concentration of 54ppb

0x0005

read-only

CO concentration, hexadecimal number, such as 0x0A0 indicating a CO concentration of 2560ppb

0x0006

read-only

O3 concentration, hexadecimal number, such as 0x0123 indicating an O3 concentration of 291ppb

0x0007

read-only

PM2.5 concentration, hexadecimal number, such as 0x0172 indicating a PM2.5 concentration of 370ug/m ³

0x0008

read-only

PM10 concentration, hexadecimal number, such as 0x0193 indicating a PM10 concentration of 403ug/m ³

0x0009

read-only

The air temperature is represented by a hexadecimal number multiplied by 100 times by adding 40, such as 0x1B00

6912/100-40=29.12℃

0x000A

read-only

Air humidity, a hexadecimal number magnified 100 times, such as 0x1603 representing 5635/100=56.35%

0x000B

read-only

Atmospheric pressure, a hexadecimal number magnified 10 times, such as 0x2784 representing 10116/10=1011.6hPa

0x000C

read-only

Wind speed, a hexadecimal number magnified 100 times, such as 0x0125, represents 293/100=2.93m/s

0x000D

read-only

Wind direction, a hexadecimal number magnified 10 times, such as 0x0C14 representing 3092/10=309.2 °

North for

0x000E

read-only

Rainfall, a hexadecimal number magnified 10 times, such as 0x0016 representing 2.2mm

Default rainfall for 10 minutes

0x000F

read-only

Radiation, hexadecimal number, such as 0x0172, represents a radiation intensity of 370W/㎡

0x0010

read-only

Illumination, a hexadecimal number magnified 100 times, for example, 0x0123 represents an illumination intensity of 2.91.Klux

0x0011

read-only

UV index, hexadecimal number, such as 0x05 representing a UV index of 5

0x0012

read-only

CO2, A hexadecimal number, such as 0x01F4, represents a CO2 concentration of 500ppm

system parameters
Stability: less than 1% within the sensor's service life, response time: less than 10 seconds
Preheating time: 30 seconds (12 hours for SO2, NO2, CO, O3)
Working current: DC12V ≤ 60ma (HCD6815) - DC12V ≤ 180ma (HCD6820) Power consumption: DC12V ≤ 0.72W (HCD6815); DC12V≤2.16W(HCD6820)
Lifespan: Except for SO2, NO2, CO, O3, PM2.5, PM10 (normal environment 1 year, high pollution environment not guaranteed), the lifespan shall not be less than 3 years.
Output: RS485, MODBUS communication protocol Shell material: ASA engineering plastic
Working environment: temperature -30~70 ℃, working humidity: 0-100 ℃, storage conditions: -40~60 ℃
Standard cable length: 3 meters
Lead length: RS485 1000 meters Protection level: IP65