E-mail
info@linhorn.com
-
Phone
15921867049
-
Address
211, Block B, Nuocheng M7 Creative Park, 1866 Hutai Road, Baoshan District, Shanghai
Shanghai Lianhang Electromechanical Technology Co., Ltd
info@linhorn.com
15921867049
211, Block B, Nuocheng M7 Creative Park, 1866 Hutai Road, Baoshan District, Shanghai
The TCT101 series has multiple configurations: timer, counter, tachometer/frequency meter. TCT101-1ABC can be set to 5 modes: timer on, timer off, pause work, oscillator, PWM (proportional time output), all modes have independent on-off time settings. TCT101-2ABC can be configured as a single counter, dual counter, increment counter, and decrement counter, and can be set through an external potentiometer. The TCT101-3ABC frequency meter comes from a TTL push-pull/line driver encoder, which can count unidirectionally or bidirectionally and has a frequency of up to 100 KHz. TCT101-4ABC-T is a complete version that can configure all the above operating modes (timer/counter/tachometer) and is equipped with Modbus RTU serial communication function for transmitting set values, time/count/frequency. The TCT101 interface ensures user convenience and can also be programmed using programming tools such as MemoriyCARDS or LABSOFTVIEW parameter setting software.
Can configure all operating modes (timer/counter/tachometer)
Equipped with Modbus RTU serial communication function
Easy to use interface
Programming can be done through programming aids

DIN rail mounted regulator/indicator
Regulator/timer adapter and end cap
Cover with protection level IP65 for regulators/timers
Memory card regulator/timer
USB to serial converter
Origin: Italy
Size: 74 x 32 x 53 mm
Main material: Noryl UL94V1
Front panel material: PC ABS UL94V0 self extinguishing type
Weight: Approximately 100 grams
Front panel protection level: IP65
Protection level of shell and terminal: IP20
Working temperature: 0 to 45 ° C
Working humidity: 35 to 95 RH%.
Certification: CE, UL
Function: Optional timer, counter or tachometer
Power supply: 24 to 230 V AC/DC ± 15% 50/60 Hz - electrically isolated 2.5KV
Power consumption: 2 watts/volt ampere
Display screen: Green display screen with 4 digits 0.4 inches+Red display screen with 4 digits 0.3 inches
Backup setting/counter: Use rechargeable capacitors to retain the value - self holding time of 7 days
Analog input potentiometer: 1 x 5/10 KOhm, used for setting points (resolution 1000 points), overlaid on DI 3
Digital input: 3 x optional NPN PNP TTL, high/low level, rising/falling edge
Auxiliary output: 24VDC-30mA (approximately 24VAC), 40mA (approximately 24VDC), 60mA (approximately 110 to 230VAC), used to power sensors/encoders
Relay output: 1 5 A -250 VAC resistive load
Serial communication: RS485 (1200 to 115200 baud)
Timer input function: start, stop, hold, reset, wait
Timer scale range: programmable time base seconds/100, seconds/10, seconds, minutes, hours
Software Protection: Set Point Command/Alarm - Parameter Access Password
Communication Protocol: Modbus RTU Modbus RTU

Industry, Machinery, Railway