E-mail
3004715684@qq.com
-
Phone
18910282270
-
Address
Haidian District, Beijing
Beijing Haifuda Technology Co., Ltd
3004715684@qq.com
18910282270
Haidian District, Beijing
Pointer insulation resistance meter library number: M411857Pointer insulation resistance meter library number: M411857
feature
There are multiple models of resistance meters available, with multiple rated voltage combinations to choose from. The MAX voltage can reach 10000V, and the MAX range can reach 1000 GQ.
Short circuit current greater than 2 mA, fast charging of capacitive equipment;
Adopting imported seismic tension gauge head, logarithmic scale, automatic range conversion,
Intuitively display the insulation resistance and absorption ratio process;
The pointer can be timed and locked at 15s, 60s, and 10min (with the h model) for easy reading and calculation of absorption ratio and polarization index.Built in lithium battery, equipped with charger, and can also be used as a backup power source for instruments with dry batteries.
Capable of withstanding short circuits and residual voltage impacts from the tested object.
Key Metrics
Rated voltage (V): 500 1000
MAX range: 40G Ω
Accuracy calculation: 5.0
MAX short-circuit current:>2mA
Working temperature and humidity: -10C~50C; < 85%RH
Power supply: 12V 2Ah lithium battery or (R6, AA) battery, 8 pieces
Size: 255 mm (L) X 135 mm (w) x80 mm (D)
Weight: 1kg





feature
There are multiple models of resistance meters available, with multiple rated voltage combinations to choose from. The MAX voltage can reach 10000V, and the MAX range can reach 1000 GQ.
Short circuit current greater than 2 mA, fast charging of capacitive equipment;
Adopting imported seismic tension gauge head, logarithmic scale, automatic range conversion,
Intuitively display the insulation resistance and absorption ratio process;
The pointer can be timed and locked at 15s, 60s, and 10min (with the h model) for easy reading and calculation of absorption ratio and polarization index.Built in lithium battery, equipped with charger, and can also be used as a backup power source for instruments with dry batteries.
Capable of withstanding short circuits and residual voltage impacts from the tested object.
Key Metrics
Rated voltage (V): 500 1000
MAX range: 40G Ω
Accuracy calculation: 5.0
MAX short-circuit current:>2mA
Working temperature and humidity: -10C~50C; < 85%RH
Power supply: 12V 2Ah lithium battery or (R6, AA) battery, 8 pieces
Size: 255 mm (L) X 135 mm (w) x80 mm (D)
Weight: 1kg