Welcome Customer !

Membership

Help

Jiapu Instrument (Suzhou) Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Jiapu Instrument (Suzhou) Co., Ltd

  • E-mail

    896757229@qq.com

  • Phone

    18013500325

  • Address

    Building 3, No. 85 Zijin Road, Huqiu District, Suzhou City, Jiangsu Province

Contact Now

Portable volatile organic gas detector

NegotiableUpdate on 02/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
VOC-350 portable volatile organic gas detector is an explosion-proof certified VOCs total amount (TVOC) detector that meets customers' needs for rapid and accurate on-site detection of VOCs total amount (TVOC).
Product Details

VOC-350Portable volatile organic gas detectorIt is a VOCs total amount (TVOC) detector that has passed explosion-proof certification, which well meets customers' needs for rapid and accurate detection of VOCs total amount (TVOC) on various sites.


The conventional configuration of the instrument is a dual detector consisting of a hydrogen flame ionization detector (FID) and a photoionization detector (PID). The dual detector not only utilizes the advantages of FID detector's response to almost all VOC gases and good linear range, but also utilizes the advantages of PID detector's fast response speed and low detection limit; And it can be equipped with three detectors, including an optional electrochemical sensor, to measure inorganic odorous gases that have no response from dual detectors such as HCL and HF, with ultra comprehensive measurement performance.


The VOC-350 detector meets the requirements for volatile organic compound (VOCs) leakage detection in standards such as GB20950-2020 "Emission Standards for Air Pollutants from Oil Storage Tanks", GB20951-2020 "Emission Standards for Air Pollutants from Oil Transport", GB20952-2020 "Emission Standards for Air Pollutants from Gas Stations", (HJ733-2014) "Technical Guidelines for Detection of Volatile Organic Compounds from Leakage and Open Liquid Level Emissions", and GB37822-2019 "Control Standards for Unorganized Emissions of Volatile Organic Compounds".


VOC-350Portable volatile organic gas detectorApplication field


LDAR (Leak Detection and Repair) testing for industries such as petrochemicals, chemicals, pharmaceuticals, resins, and fertilizers

Soil VOCs detection

VOCs testing in factory workshop environment

Unorganized on-site emergency testing

Rapid detection of fixed pollution source emissions

Evaluation of the effectiveness of VOCs treatment facilities

VOCs traceability investigation

VOCs emission detection in wastewater tank