CHARACTERISTICS
1. Adopting a large TFT true color LCD touch screen (800X480) human-machine interface, users can easily program and operate directly on the touch screen.
| capacity | 600W | 1.2KW | 2.4KW | 5KW | |
| input voltage | 220V±18% 1φ2W 50Hz±5Hz | ||||
|
lose go out electricity press |
30V | 20 | 40 | 80 | 167 |
| 60V | 10 | 20 | 40 | 84 | |
| 120V | 5 | 10 | 20 | 42 | |
| 300V | 2 | 5 | 8 | 16.7 | |
| 600V | 1 | 2 | 4 | 8.4 | |
| DC voltage ripple | ≤ 300mV (rms) (80% pure resistive load) | ||||
| Adjust stride | 0.1V | ||||
| Line Regulation | ±0.1%FS | ||||
| Load Regulation | ±1%FS | ||||
| display interface | TFT LCD 触摸屏 | ||||
| Voltage regulation range | 0~100% adjustable rated voltage | ||||
| Current range | 0~100% rated current adjustable | ||||
| Automatic protection function | It has automatic protection function in case of output overvoltage, overcurrent, module overheating and short circuit | ||||
| load characteristics | Suitable for various loads | ||||
| overload capacity | The maximum current limit is 105% of the rated current value | ||||
| overall efficiency | ≥85% | ||||
| insulation test | DC500V, Output to shell ≥ 7M | ||||
| Withstand Voltage Test | Input no arcing breakdown phenomenon for shell AC1500V/1 minute | ||||
| Audible noise | ≤60dB | ||||
| cooling method | air cooling | ||||
| Number of programmable groups | There are a total of 30 groups, each with memory voltage, current, and time equivalent values | ||||
| Number of memorable groups | There are a total of 9 groups, each with equivalent values of memory voltage, current, and time, which can be easily recalled | ||||
| Pressure limit setting | 0-100% maximum voltage value | ||||
| Current limit setting | 0-100% maximum current value | ||||
| communication interface | RS232/RS485 | ||||
|
working environment |
Environmental temperature: -10 ℃~70 ℃ | ||||
| Relative humidity: 20~90% (non condensing state) | |||||
| The usage location is free from flammable, explosive, and corrosive media, as well as strong electromagnetic interference, abnormal vibration, and impact | |||||
| capacity | 10KW | 15KW | 20KW | 30KW | 60KW | 120KW | 240KW | 360KW | 480KW | |
| input voltage | 380V±15% 3φ4W 50Hz±5Hz | |||||||||
|
lose go out electricity press |
300V | 40 | 60 | 80 | 120 | 240 | 480 | 960 | ||
| 600V | 20 | 30 | 40 | 60 | 120 | 240 | 480 | 720 | 960 | |
| 1000V | 12 | 18 | 24 | 36 | 72 | 114 | 288 | 432 | 576 | |
| DC voltage ripple | ≤ 300mV (rms) (80% pure resistive load) | |||||||||
| Adjust stride | 0.1V | |||||||||
| Line Regulation | ±0.1%FS | |||||||||
| Load Regulation | ±1%FS | |||||||||
| output display | LCD触摸屏 | |||||||||
| Voltage regulation range | 0~100% adjustable rated voltage | |||||||||
| Current range | 0~100% rated current adjustable | |||||||||
| Automatic protection function | It has automatic protection function in case of output overvoltage, overcurrent, module overheating and short circuit | |||||||||
| load characteristics | Suitable for various loads | |||||||||
| overload capacity | The maximum current limit is 105% of the rated current value | |||||||||
| overall efficiency | ≥85% | |||||||||
| insulation test | DC500V, Output to shell ≥ 7M | |||||||||
| Withstand Voltage Test | Input no arcing breakdown phenomenon for shell AC1500V/1 minute | |||||||||
| Audible noise | ≤60dB | |||||||||
| cooling method | air cooling | |||||||||
| Number of programmable groups | There are a total of 30 groups, each with memory voltage, current, and time equivalent values | |||||||||
| Number of memorable groups | There are a total of 9 groups, each with equivalent values of memory voltage, current, and time, which can be easily recalled | |||||||||
| Pressure limit setting | 0-100% maximum voltage value | |||||||||
| Current limit setting | 0-100% maximum current value | |||||||||
| communication interface | RS232/RS485 | |||||||||
| working environment | Environmental temperature: -10 ℃~70 ℃ | |||||||||
| Relative humidity: 20~90% (non condensing state) | ||||||||||
| The usage location is free from flammable, explosive, and corrosive media, as well as strong electromagnetic interference, abnormal vibration, and impact | ||||||||||