The Q647F fixed pneumatic ball valve produced by Shanghai Yuhu Company is a new generation of high-performance pneumatic ball valve, suitable for long-distance pipelines and general industrial pipelines. Its strength, safety, and resistance to harsh environments have been specially considered in the design. The fixed pneumatic ball valve is suitable for various corrosive and non corrosive media. Compared with floating ball valves, the Q647F fixed pneumatic ball valve transfers all the force generated by the fluid pressure in front of the valve on the ball to the bearing during operation, without causing the ball to move towards the valve seat. Therefore, the valve seat deformation is small, the sealing performance is stable, and the service life is long. It is suitable for high-pressure and large-diameter applications. Advanced spring pre seat components with self tightening characteristics achieve upstream sealing. Each valve has two valve seats, which can seal in each direction, so there is no flow restriction during installation, and it is bi-directional. This valve has two types of valve body structures: two-piece and three piece. The middle flange is connected by bolts, and the seal is made of reinforced polytetrafluoroethylene embedded in a stainless steel ring. The rear of the steel ring is equipped with a spring to ensure that the valve seat is tightly attached to the ball, maintaining a seal. Both the upper and lower valve stems are equipped with PTFE bearings to reduce friction and make operation effortless. There are no adjustment plates at the bottom of the small shaft to ensure the joint position between the ball and the sealing ring. The fixed pneumatic ball valve adopts a full bore structure to ensure that the valve flow hole is consistent with the inner diameter of the pipeline for pipeline cleaning. Paired with an electrical valve positioner, it can control operation by inputting a 4-20mADC signal and a 0.4-0.7MPa gas source, achieving adjustments to parameters such as pressure, flow rate, temperature, and liquid level.
(1) The fixed pneumatic ball valve adopts a fixed ball design, and the relative moving parts are made of self-lubricating materials with extremely low friction coefficient, resulting in low operating torque. In addition, the long-term sealing of the sealing grease makes the operation more flexible.
(2) The fixed pneumatic ball valve adopts a full bore or reduced diameter design, with low flow resistance.
(3) The fixed pneumatic ball valve adopts a fixed ball design and adds a pre tension spring, making the ball valve have automatic pressure relief function.
(4) Each ball valve has two movable sealing seats that can seal in both directions, so there is no need to consider the flow direction of the medium during installation.
(5) Featuring a fire-resistant and anti-static structure, conductive springs are installed between the valve stem and valve body, as well as between the valve stem and ball body, to prevent static electricity from igniting flammable media. Ensure system security.
(6) The fire-resistant structure provides dual protection. In the event of a fire that burns the sealing ring, all sealing parts of the ball valve can form a metal to metal hard sealing structure.
| Nominal diameter DN (mm) | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 600 | 700 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal pressure (MPa) | PN1.0、2、4.0、6.4、10.0MPa; ANSI 150 300 600 900LB | |||||||||||||
| Valve body form | Two stage cast valve body | |||||||||||||
| Valve core form | O-shaped spherical valve core | |||||||||||||
| sealing packing | V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos textile packing, graphite packing | |||||||||||||
| connection type | flanged | |||||||||||||
| flow characteristics | Approximate quick opening type | |||||||||||||
| leakage | According to GB/T4213-92, less than 0.01% of rated KV (soft seal: zero leakage) | |||||||||||||
| adjustable range | 250:1 | 250:1 | ||||||||||||
| basic error | Equipped with locator: less than ± 2% of the full stroke | |||||||||||||
| dead zone | Equipped with locator: less than ± 2% of the full stroke | |||||||||||||
| Applicable Temperature | PTFE≤180℃; PPL≤280℃; Metal seal ≥ 300 ℃ | |||||||||||||
| Configure execution mechanism | GT, AT, AR, AW series single and double acting pneumatic actuators | |||||||||||||
| Control method | Two position switch control, 4-20mA analog control | |||||||||||||
| Model of actuator | GT, AT, AW series single and double acting pneumatic actuators |
|---|---|
| gas supply pressure | 0.4~0.7MPa |
| air source interface | G1/4"、G1/8"、G3/8"、G1/2" |
| ambient temperature | -30~+70℃ |
| mode of action | Single acting actuator: gas closed type (B) - valve position open when gas is lost (FO); Pneumatic opening (K) - valve position closed when gas is lost (FC) Double acting actuator: gas closed type (B) - valve position maintenance during gas loss (FL); Pneumatic opening (K) - valve position maintenance during gas loss (FL) |
| Can be equipped with accessories | Positioner, solenoid valve, air filter pressure reducer, holding valve, travel switch, valve position transmitter, handwheel mechanism, etc |
Adopting a new type of pneumatic actuator, with double acting and single acting (spring reset), gear rack transmission, safe and reliable; The large-diameter valve adopts a series of AW type pneumatic actuators with fork type transmission, with a reasonable structure and high output force, and is available in double acting and single acting types.
1. Gear type dual piston, with large output torque and small volume.
2. The cylinder is made of aluminum material, which is lightweight and aesthetically pleasing.
3. Manual operating mechanisms can be installed at the top and bottom.
4. The rack and pinion connection can adjust the opening angle and rated flow rate.
5. The actuator can be equipped with live signal feedback indicators and accessories to achieve automated operation.
6. The IS05211 standard connection provides convenience for the installation and replacement of products.
7. The adjustable screws at both ends provide a ± 4 ° adjustable range for standard products between 0 ° and 90 °. Ensure synchronization accuracy with internal threaded pneumatic ball valves.
| Nominal diameter (mm) | DN50~700 | |||||
|---|---|---|---|---|---|---|
| Nominal pressure PN (MPa) | 1.6 | 2.5 | 4.0 | |||
| Nominal Pressure PS(MPa) |
strength test | 2.4 | 3.8 | 6.0 | ||
| Sealing Test | 1.8 | 2.8 | 4.4 | |||
| Material/Material Code | C | P | R | |||
| Main components | valve body | WCB | ZG1Cr18Ni9Ti | ZG0Cr18Ni12Mo2Ti | ||
| Sphere | 2Cr13 | 1Cr18Ni9Ti | 1Cr18Ni12MoTi | |||
| Valve stem | 2Cr13 | 1Cr18Ni9Ti | 1Cr18Ni12MoTi | |||
| sealing ring | Enhanced polytetrafluoroethylene for polystyrene hard alloy | |||||
| Packing material | Polytetrafluoroethylene flexible graphite | |||||
| Applicable working conditions | Applicable Medium | Water, steam, oil products | Nitric acid | Acetic acid | ||
| Applicable Temperature | -28℃ - 300℃ | |||||
| actuator | model | AW/DA/SR series, GTD/GTE series, QGSY series, etc | ||||
| air supply pressure | 0.4-0.7MPa | |||||
| execution standard | design and manufacturing | structural length | Flange size | Pressure and temperature | Experimental verification | |
| GB12237 | GB12221 | GB9113 | GB9131 | GB13927 | ||
| Design and Manufacturing | GB12237-89、API608、API 6D、JPI 7S-48、BS5351、DIN3357 |
|---|---|
| Flange size | JB/T74~90、GB9112~9131、HGJ44~76、SH3406、ANSI B16.5、JIS B2212~2214、DIN2543 |
| structural length | GB12221-89、ANSI B16.10、JIS B2002、NF E29-305、DIN3202 |
| Inspection and Testing | JB/T 9092、API 598、GB/T13927 |
(1) Valve body parameters: nominal diameter, working pressure, process medium, usage scenario, valve body material, and other series of parameters.
(2) Actuator parameters: actuator form, control mode, control signal (4-20mA, 1-5V), action mode (air open, air closed)
Please provide the above technical parameters in as much detail as possible to facilitate our company's operations and technical personnel to accurately select for you. If you have any questions You can call us and we will do our best to provide you with high-quality service!