SH-120 Micro Blood Centrifuge

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The SH-120 micro blood centrifuge is suitable for precise determination of hematocrit values and can also be used for precipitation separation of micro amounts of blood and solutions. The amount of blood taken is small, (earlobe blood can be used) the disposal volume is large, the blood collection is convenient, the centrifugation time is short, the detection is accurate, the work efficiency is high, and the supporting facilities are complete.
Product Details
  SH-120 Micro Blood CentrifugeMain technical parameters:
1. Power supply: AC 220V ± 10V 50HZ
2. Overall power: 100W
3. Centrifugal speed: 1500-12000 revolutions per minute (adjustable)
4. Maximum relative centrifugal force: 15300g
5. Centrifugal capacity: 24 ¢ 1.5mm × 75mm (glass capillary tubes)
6. Timing range: 0-60 minutes
7. Rotary table form: horizontal type
8. Startup time: 1 minute
9. Braking time: 2 minutes
  SH-120 Micro Blood CentrifugeUsage:
Firstly, open the machine cover, remove the cap and aluminum cover plate, and use the glass capillary tube provided with the machine (blood sample has been taken)
Place the centrifuge disc into slots 1-24 according to the scale (the amount of blood added to each capillary tube is basically equal), cover with an aluminum cover plate and fix it with a cap. Turn on the power and turn on the power switch. The power indicator light will turn on, and then select the required working time and speed (which can be selected according to needs). Close the cover and the centrifuge will enter working mode.
SH-120微量血液离心机
Notes:
1. It is strictly prohibited for any liquids or debris to enter the studio, otherwise it may damage the host.
2. The instrument casing should be properly grounded to prevent accidents caused by moisture damage to the entire machine.
3. When the centrifuge head is running, please do not open the hood. You must wait until it stops running before opening the hood and removing the glass capillary tube
4. If any malfunction is found while using the instrument, please seek maintenance personnel for repair.