E-mail
info@testo.com.cn
-
Phone
18918106372
-
Address
Building 34, 15, Xinxing Industrial Park, No. 258 Shenzhuan Road, Songjiang District, Shanghai
Detu Instrument International Trade (Shanghai) Co., Ltd
info@testo.com.cn
18918106372
Building 34, 15, Xinxing Industrial Park, No. 258 Shenzhuan Road, Songjiang District, Shanghai
the testo 350Smoke analyzer analysis box - orange versionBoth enhanced anti-interference SO2 sensors and infrared CO2 sensors can be configured, as well as CO, NO, NO2 sensors with different ranges suitable for different measurement tasks. The highly integrated and modular gas pretreatment function ensures that pre cooled dry flue gas enters the sensing module, achieving accurate gas measurement.
For high humidity and low sulfur measurement conditions after wet desulfurization, a fully heated flue gas probe can be equipped to achieve efficient measurement without condensation during the sampling process;
For high concentration CO working conditions, the single slot range expansion function can be automatically activated to achieve high concentration measurement;
For the measurement of NOx in industrial flue gas denitrification engineering processes, linkage measurement of measurement points before and after catalysis can be achieved; And separate measurements of NO and NO2;
For carbon emission measurement, the configured NDIR-CO2 sensor can achieve real-time measurement of CO2 concentration and emission mass flow measurement.
Testo350 is capable of measuring requirements under different working conditions and is widely used in fields such as environmental emissions, energy conservation and emission reduction, boiler energy efficiency, exhaust gas treatment and treatment, industrial process gas measurement, and laboratory research.
the testo 350Smoke analyzer analysis box - orange versionComposed of two components
Testeo 350 Handheld Device (Independent Product): Used for performing measurements, operating settings, and controlling the entire analyzer. It has a color display screen, displays measurement data, connects to a printer, and has a built-in preset menu. The interface navigation is intuitive and simple.
Testeo 350 analysis box: equipped with maintenance compartment and sensor compartment. The maintenance compartment is used for the maintenance and upkeep of instrument batteries, air pumps, etc., while the sensor compartment facilitates users' maintenance, inspection, and self replacement of sensors: plug and play.
Built in gas pretreatment module |
The flue gas pretreatment module adopts the Peltier refrigeration principle to achieve gas water separation, cool the high-temperature and high humidity flue gas, and quickly dry it before directly entering the measurement sensor to measure the concentration of dry flue gas. |
Real time visual condensate storage tank |
The pre treated flue gas produces condensed water that is extracted into the condensation tank through a peristaltic pump. The transparent and visible scale and automatic condensed water level monitoring alarm protect the sensor from damage. |
Instrument indicator light |
The indicator lights can reflect different operating conditions through flashing states such as green yellow red on the analysis box panel; |
Efficient filter element |
The filter elements are installed separately in the flue gas intake air path, air intake air path, and single slot extended intake air path. The filter element protective cover window is designed with transparency, allowing for clear observation of the pollution level of the filter element; |
host interface |
Multiple standard industrial interfaces: smoke, pressure, temperature, data bus&USB interfaces, etc., sturdy and durable; |
gas sensor |
Testo350 can monitor different gas components, and users can directly replace the sensor on site without the need for gas calibration, and it can be put into use. |
Sensor zeroing |
The zeroing function of the gas sensor allows fresh air to enter the sensor for zeroing through the switching of the electromagnetic valve gas path, which can keep the flue gas probe in the flue for measurement at the next time point or program measurement. |
Automatic pressure zeroing sensor |
Can ensure long-term measurement of flow rate and velocity without human supervision, and can simultaneously measure smoke concentration. |
External cooling circuit |
By designing the electrical and sensor parts of the instrument to be separated from the ambient air, Peltier heat dissipation and cooling are achieved through heat exchange inside the instrument, while avoiding contact with smoke and harmful gases in the external ambient air. |
Technical Specifications | |
size |
330 x 128 x 438 mm |
Operating temperature |
-5 ~ +45 °C |
shell |
ABS |
Protection level |
IP40 |
Battery Type |
lithium battery |
battery life |
5 hours |
power supply |
AC 100V-240V (50-60 Hz) |
DC voltage input |
11V - 40V |
Dew point calculation |
0 °Ctd; 99 °Ctd |
Maximum dust load |
20 g/m ³ smoke and dust volume |
Maximum smoke negative pressure |
-300 mbar |
Maximum positive pressure of flue gas |
50 mbar |
Trigger signal input |
Voltage 5-12 V (rising or falling) pulse frequency>1 s. Load: 5 V/max, 5 mA, 12 V/max.40 mA |
Maximum humidity load |
Dew point temperature at the inlet of the analyzer flue gas+70 ℃ |
Hose length |
Maximum length of 16.2 m (connected by 5 extension hoses) |
pump flow rate |
1 liter/minute, with flow monitoring |
Maximum memory |
250000 readings |
Storage temperature |
-20 ~ +50 °C |
weight |
4800 g |
The testo 350 smoke analyzer analysis box - orange version comes standard with an O2 sensor, built-in differential pressure and ambient temperature (NTC) sensors, K-type (NiCr Ni) and S-type (Pt10Rh Pt) thermocouple connection interfaces, Detu data bus interface, trigger input interface, rechargeable battery, data storage module, and USB interface.