Stainless steel lined fluoroplastic globe valve production

NegotiableUpdate on 05/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

J41F46 stainless steel lined fluoroplastic globe valve is suitable for use in pipelines with various concentrations of aqua regia, flowing acid, hydrochloric acid, fluoric acid, and various organic acids, strong acids, and strong oxidants at -50 ℃~+150 ℃. It is also suitable for use in pipelines with various concentrations of strong alkali organic solvents and other corrosive gases and liquid media.

Product Details

J41F46Stainless steel lined fluoroplastic globe valveProduct Description

J41F4-16 and J41F46-16 fluorine lined globe valves are suitable for use in pipelines with various concentrations of aqua regia, flowing acid, hydrochloric acid, hydrofluoric acid, and various organic acids, strong acids, and strong oxidants at -50~150 ℃. They are also suitable for use in pipelines with various concentrations of strong alkaline organic solvents and other corrosive gases and liquid media. It has the advantages of compact structure, flexible opening and closing, strong corrosion resistance, and short stroke (generally 1/4 of the nominal diameter), and is widely used in pipeline systems such as petroleum and chemical industries to cut off media. However, it should be emphasized that fluorine lined globe valves are strictly prohibited from flow regulation to prevent high-speed media flow generated at the throttle outlet from eroding and damaging the sealing surface.

The opening and closing component of a globe valve is a plug shaped valve disc, with a flat or conical sealing surface. The valve disc moves in a straight line along the centerline of the fluid. The movement form of the valve stem includes a lifting rod type (the valve stem is lifted and lowered without the handwheel lifting), as well as a lifting rotating rod type (the handwheel rotates and lifts together with the valve stem, and the nut is set on the valve body). Globe valves are only suitable for fully open and fully closed, and are not allowed to be adjusted or throttled.

638036293152776074602.jpg

Product application:

The fluorine lined flange globe valve is suitable for use in pipelines with various concentrations of aqua regia, flowing acid, hydrochloric acid fluoric acid, and various organic acids, strong acids, strong oxidants at -50 ℃~+150 ℃. It is also suitable for use in pipelines with various concentrations of strong alkali organic solvents and other corrosive gases and liquid media. Used to control corrosive or highly corrosive media, the surface of the valve body cavity is covered with various fluoroplastics for selection, suitable for different working temperatures and fluid pipelines, and has the characteristics of high strength and good corrosion resistance.

Structural features:

1. Compared with gate valves, globe valves have a simpler structure and are easier to manufacture and maintain.

2. The sealing surface is not easily worn or scratched, with good sealing performance and long service life.

3. The valve disc stroke during opening and closing is small, the opening and closing time is short, and the valve height is small.

4. The valve disc and valve stem are designed as an integrated structure, which is compact and safe to use.

5. There are three structural forms of globe valves: straight through, direct flow, and angle type. The straight through type is commonly used, while the angle type can be installed at the corners of the pipeline system. The direct flow type has a smaller flow resistance than the globe valve.

6. Pneumatic and electric devices can be configured according to user needs to meet the needs of remote control and program control.

7. Replacing the lining material of the parts can be applied to various media.

638036293572687019523.jpg

Technical specifications:

1. Design and Manufacturing: GB/T12235.

2. Structural length: GB12221, HG/T3704-2003.

3. Flange dimensions: GB/T9113.1-2000, ANSI B16.5a.

4. Structural forms: straight through, DC, angular.

5. Drive modes: manual, pneumatic, electric.

6. Nominal pressure: 0.6, 1.0, 1.6, 2.5MPa, Class150, JIS10K.

7. Pressure test: GB/T13927-92, API598.

Standard specification for J41F46 fluorine lined globe valve:

Design and Manufacturing Standards: GB/T 12233, GB/T 12235

Structural length standard: GB/T 12221-2005

Connection flange standard: GB/T 9113

Pressure and temperature rating: GB/T 12224-2005

Test and Inspection Standard: GB/T 13927-2008

638036293576749148607.jpg

Applicable temperature:

Lining and valve seat Applicable temperature (℃) Applicable Medium
PTFE(F4) ≤180 Various concentrations of highly corrosive media such as acids, bases, salts, aqua regia, organic acids, etc., except for molten alkali metals and elemental fluorine
PCTFE(F3) ≤120
FEP(F46) ≤150
PFA (Fusible F4) ≤180
PVDF(F2) ≤100
RPTFE(RF4) ≤180

638036293149182666990.jpg


J41F46Stainless steel lined fluoroplastic globe valvePerformance specifications:

Follow the rules STANDARD
Designed for Manufacturing GB 12233/GB 12235
structural length GB 12221 (Long Short Series)
Flange size JB 78/JB 79(GB,HG,SH)
pressure test GB/T 13927
logo GB 12220
supply GB/T 12252

Main component material list:

serial number Part Name gray cast iron cast steel stainless steel Ultra low carbon stainless steel
Z C P R PL RL
1 Valve body, valve cover HT250 WCB CF8 CF8M CF3 CF3M
2 Valve disc, valve stem 35 1Cr13 1Cr18NI9 1Cr18Ni12Mo2Ti 00Cr18Ni10 00Cr17Ni14Mo2
3 swivel bolt 35 35 1Cr17Ni2 1Cr17Ni2 1Cr17Ni2 1Cr17Ni2
4 Lining layer/valve seat Rubber lined (NR) FEP (F46) PCTFE (F3) PFA (soluble polytetrafluoroethylene)
5 filler PTFE(F4) PTFE(F4)
6 gland WCB WCB CF8 CF8M CF3 CF3M
7 stem nut ZCuAl10Fe3 ZCuAl10Fe3
8 bolt 35 35 1Cr17Ni2 1Cr17Ni2 1Cr17Ni9Ti 1Cr17Ni9Ti
9 nut 45 45 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9
10 handwheel HT200 HT200 WCC WCC WCC WCC

衬氟截止阀14_副本.jpg

Main appearance and connection dimensions:

Nominal Diameter standard value reference value
DN

(mm)

NPS

(inch)

L D D1 D2 f b Z-φd W D0 H WT(Kg)
PN 1.0MPa
15 1/2 130 95 65 45 2 14 4-φ14 100 235 260 6.5
20 3/4 150 105 75 55 2 16 4-φ14 100 240 265 7
25 1 160 115 85 65 2 16 4-φ14 120 245 270 7.87
32 11/4 180 135 100 78 2 18 4-φ18 140 255 285 11
40 11/2 200 145 110 85 3 18 4-φ18 140 285 315 13
50 2 230 160 125 100 3 20 4-φ18 160 295 330 15
65 21/2 290 180 145 120 3 20 4-φ18 180 350 395 23
80 3 310 195 160 135 3 22 4-φ18 240 395 445 38
100 4 350 215 180 155 3 22 8-φ18 240 450 490 42
125 5 400 245 210 185 3 24 8-φ18 280 525 555 55
150 6 480 280 240 210 3 24 8-φ23 320 605 645 77
200 8 495 335 295 265 3 26 8-φ23 360 645 765 135
250 10 622 390 350 320 3 28 12-φ23 400 685 805 220
300 12 698 440 400 368 4 28 12-φ23 400 710 814 277
350 14 787 500 460 428 4 30 16-φ23 450 750 855 320
PN 1.6MPa
15 1/2 130 95 65 45 2 14 4-φ14 100 240 265 7
20 3/4 150 105 75 55 2 16 4-φ14 100 245 270 7.6
25 1 160 115 85 65 2 16 4-φ14 120 250 270 8.2
32 11/4 180 135 100 78 2 18 4-φ18 140 260 290 12
40 11/2 200 145 110 85 3 18 4-φ18 140 285 320 14
50 2 230 160 125 100 3 20 4-φ18 160 300 335 18
65 21/2 290 180 145 120 3 20 4-φ18 180 355 400 26
80 3 310 195 160 135 3 22 8-φ18 240 400 450 40
100 4 350 215 180 155 3 24 8-φ18 240 455 495 50
125 5 400 245 210 185 3 26 8-φ18 280 530 560 65
150 6 480 280 240 210 3 28 8-φ23 320 610 650 85
200 8 495 335 295 265 3 30 12-φ23 360 650 770 150
250 10 622 405 355 320 3 32 12-φ25 400 690 810 245
300 12 698 460 410 375 4 34 12-φ25 400 730 845 295

638036293581280520163.jpg

Globe valves belong to forced sealing valves, so when the valve is closed, pressure must be applied to the valve disc to force the sealing surface not to leak. When the medium enters the valve from below the valve disc, the resistance that the operating force needs to overcome is the frictional force between the valve stem and the packing, as well as the thrust generated by the pressure of the medium. The force required to close the valve is greater than the force required to open it, so the diameter of the valve stem should be larger, otherwise the valve stem bending fault may occur. In recent years, with the emergence of self sealing valves, the flow of medium in shut-off valves has shifted from above the valve disc into the valve chamber. Under the pressure of the medium, the force required to close the valve is small, while the force required to open the valve is large, resulting in a corresponding reduction in the diameter of the valve stem. Meanwhile, under the influence of the medium, this type of valve is also relatively tight. The "Three Modernizations" of valves in our country once stipulated that the flow direction of globe valves should be from top to bottom.

When the shut-off valve is opened and the opening height of the valve disc is 25% to 30% of the nominal diameter, the flow rate has reached, indicating that the valve has reached the fully open position. So the fully open position of the shut-off valve should be determined by the stroke of the valve disc. The outer shell of the fluorine lined straight through globe valve is made of investment casting precision, with high strength and smooth appearance. The internal cavity, valve body, valve cover, valve disc and other components (i.e. chemical medium flow components) in contact with the liquid are all lined or coated with excellent corrosion-resistant materials (fluoroplastics). The molding process technology is used to make the valve have both the strength and corrosion resistance of metal. The valve seat adopts integral polymer as the sealing material, which has excellent sealing performance over a wide temperature and pressure range; The opening and closing element (valve disc) is a valve driven by the valve stem and moves up and down along the central axis of the valve seat. It is mainly used to connect or cut off the medium in the pipeline, but cannot be used for throttling.

The installation and usage precautions are as follows:

1) Fluorine lined globe valves should be stored in a dry and ventilated room, and the valve channels should be blocked at both ends.

2) The fluorine lined globe valve stored should be regularly inspected and cleaned of dirt. Special attention should be paid to the cleanliness of the sealing surface to prevent damage to it.

3) Before installation, carefully check whether the markings of the fluorine lined globe valve match the usage requirements.

4) Before installation, the inner cavity and sealing surface of the fluorine lined globe valve should be checked. If there is dirt, it should be wiped clean with a cleaning cloth.

5) Before installation, check whether the packing is tightly compressed, ensuring the sealing of the packing and not hindering the rotation of the valve stem.

6) During the pressure test of the system or pipeline after installation, the fluorine lined globe valve should be in the fully open position.

7) When in use, lubricant should be regularly injected into the trapezoidal thread of the valve stem.

8) When opening or closing a manual fluorine lined globe valve, the handwheel should be used instead of auxiliary levers or other tools.

9) Fluorine lined globe valves should be regularly inspected after use to check for wear on the sealing surface, valve stem, gaskets, and packing. If damaged or ineffective, it should be repaired or replaced in a timely manner.

10) For the storage, maintenance, installation, and use of the transmission device of electric and pneumatic fluorine lined globe valves, please refer to the "User Manual for Fluorine lined Globe Valve Electric Device".

638036285531657008862.jpg

Ordering Notice:

1、 ① Product name and model ② Caliber ③ Is there any accessory for us to correctly select for you ④ Operating pressure ⑤ Temperature of the medium used.

2、 If the company's model has already been selected by the design unit, please order directly from our sales department according to the model.

3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our valve company experts will review and control them for you. If you have any questions: Please: We will do our best to provide you with high-quality service. We provide comprehensive and professional "valve system solutions" and are also willing to help users solve problems encountered in production.