The TSI 9535/9545 multi parameter anemometer from the United States is a cost-effective device that can measure and record multiple parameters in the air simultaneously with multiple sensors. The instrument can measure wind speed, temperature, and calculate air volume.
TSI 9535/9545 Multi Parameter Anemometer Product Introduction:
The 9535 and 9545 anemometers are multifunctional instruments with high cost-effectiveness.This instrument can use a probe with multiple sensors to simultaneously measure and record multiple parameters in the air.Both models of instruments can measure wind speed, temperature, and calculate air volume.9545 The model can also measure relative humidity and calculate dew point temperature and wet bulb temperature.9535 and9535-AThe model has a stretchable straight probe.9545 and9545-AArticulated probe with stretchable and bendable features
TSI 9535/9545 multi parameter anemometer product features from the United States:
Easy to operate
Precise wind speed measurement
Simultaneously measure temperature and wind speed
Many can display three measurement parameters simultaneously
Measurable humidity (9545 and 9545-A)
Calculated volumetric flow rate, in actual/standard conditions
Switching between quasi state wind speeds
Including LogDat2TM data download software
The probe can be bent (9535-A and 9545-A)
TSI 9535/9545 multi parameter anemometer product parameters from the United States:
Testing parameters/models |
9535 |
9535-A |
9545 |
9545-A |
|
wind speed |
scope |
0~30 m/s |
|||
Accuracy 1&2 |
± 3% of the reading or ± 0.015m/s, whichever is higher |
||||
resolution |
0.01m/s |
||||
Duct size |
1~635cm, The increment is 0.1cm |
||||
Volume flow range |
The actual range is a function of wind speed and duct size |
||||
temperature |
scope |
-18 ~ 93℃ |
-10 ~ 60℃ |
||
Accuracy 3 |
± 0.3℃ |
||||
resolution |
0.1℃ |
||||
|
relative humidity (Wet bulb temperature, dew point temperature) |
scope |
/ |
0~95%RH | ||
Accuracy 4 |
± 3%RH |
||||
resolution |
0.1%RH |
||||
Data storage capability |
12700 data points and 100 data sets |
||||
Data collection interval |
1s~1h |
||||
Time constant user |
customize |
||||
Operating Temperature |
sensor |
-18~93℃ |
-10~60℃ |
||
Storage temperature |
-20~40℃ |
||||
Instrument weight (with battery) |
0.27kg |
||||
External dimensions of the host |
8.4 cm × 17.8 cm × 4.4 cm |
||||
Probe size |
length |
101.6 cm |
|||
Top diameter |
7.0 mm |
/ |
7.0 mm |
/ |
|
Base diameter |
13.0 mm |
13.0 mm |
|||
Bendable probe |
length |
/ |
19.7 cm |
/ |
19.7 cm |
Size and diameter |
9.5 mm |
9.5 mm |
|||
power supply |
Four AA batteries or optional AC adapter |
||||
When the temperature range exceeds 5-65 ℃, the measured wind speed needs to be corrected;
2. The accuracy refers to the precision when measuring 0.15~30m/s
3. The accuracy refers to the precision when measuring the ambient temperature at 25 ℃. After the temperature changes, an additional compensation of 0.03 ℃/℃ is required
The precision refers to the accuracy when measuring the ambient temperature at 25 ℃. After the temperature changes, an additional compensation of 0.2% RH/℃ is required, including 1% hysteresis