Trace Hydrogen Sulfide H2S Online Analysis System Gas Analyzer

NegotiableUpdate on 05/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The micro hydrogen sulfide H2S online analysis system AMI specializes in the analysis unit technology, which is first a compact and small metal block that undergoes a series of complex machining procedures and then undergoes nickel plating and anti-corrosion treatment.

Product Details

precise measurement:

In the case of micro measurement, electrochemistryH2SThe analyzer provides accurate measurements. Because the analyzer uses a sensor consisting of an anode and a cathode in an electrolyte aqueous solution. If the sample gas exists when passing through the sensorH2SMolecules and electrons will flow from the anode to the cathode and generate an electric current. The magnitude of the current is proportional to the number of electrons moving to the cathode, and the analyzer uses it to obtainH2Sreading. The accuracy of this method enables the analyzer to handle applications that require trace measurements as low as a few parts per billion, which other measurement methods cannot match.

Cost effective solutions:

When considering all the ongoing costs required for other measurement options, electrochemistryH2SThe value of the analyzer is very tempting. The price of disposable dye tubes is much lower than that of analyzers, but after several months of use, the total cost will skyrocket. Combined with manual requirements, the option of dyeing tube may exceed the cost of purchasing an electrochemical analyzer within a few months. Lead acid strip analyzer is also a user's choice. However, at the time of purchase, their cost is higher than that of electrochemistryH2SThe analyzer is high, and the maintenance cost is also higher.

Required maintenance:

mostH2SAnalysts require regular maintenance, but their maintenance is very simple and easier to complete than other technical analyzers. For example, the operator of a lead acetate strip analyzer must inspect the condition of moving parts and replace worn components or consumables if necessary. On the contrary, the maintenance of electrochemical analyzers is relatively easy, and in most cases, only expired ones need to be replacedH2SIt's just a sensor. Therefore, when considering the use of anyH2SWhen using an analyzer, please weigh the maintenance requirements, as this is part of your purchasing decision.


Technical Indicators:

Ø3 A standard output range0-10ppm0-50ppm0-100ppm

ØSelectable range0-500ppm0-1000ppmand2000ppmAt the same time, the output range corresponds to controlling two alarms, analog output, and data logs. Therefore4All functions operate within the same range.

Ødigital display3 1/2Digital LCD displayDigital display based on the selected range0.00ppm ~ 100ppm

Øcall the police 2Adjustable hydrogen sulfide(H2S)Content alarm, dry contact point5A.@24VDC/115VAC

Øalarm delay programmable0-300minute

Øalarm delay0-120Optional in minutes

ØIsolation output signal1-5VDCor4-20mACorresponding to the selected output signal0-10ppm0-50ppm0-100ppm

Ødata log log data1minute@15sky 2minute@30Tian, corresponding to the selected output signal0-10ppm0-50ppm0-100ppm

Øpower supply10-28VDC/ 115VAC<70mA. @ 12VDCNo heater option,< 24W@12VDCWith heater option


AMIThe analysis unit technology possessed by Zhuangli is first and foremost a compact and small metal block, which undergoes a series of complex machining programs,After nickel plating and anti-corrosion treatment. The gas analysis room contains a series of pre processed criss crossing gas channels, connected to which are:An optional flow control valve, 3-Channel selection valve(Used for switching sample gases/Calibration gas/Cut off control),flow meter and3A gas connection joint.All of these make up our integrated analysis room.

Compared to competitors,AMIDo not use a large number of connecting pipelines, joints, valves, and flow meters in the analysis system. If the original old technology is used, multiple connections themselves may have multiple leakage possibilities, which increases the corresponding time, requires the volume of connecting lines to be placed, and requires more manpower. ButAMIThe new technology has eliminated these criticisms.

The design of the front panel sensor installation port allows for convenient and quick installationH2SSensors can be replaced or replaced without the need for other tools or disassembly

Any sensitive or important component among them. This process is less than

1It can be completed within minutes.



Trace Hydrogen Sulfide H2S Online Analysis SystemTrace Hydrogen Sulfide H2S Online Analysis System