Transformer capacity and no-load load characteristic tester
| ·Functional Features |
| 1. The no-load test does not require an external power supply or voltage regulator, and can be completed using the built-in power supply. 2. For transformers without nameplates, there is no need to manually input any parameters, and the results can be automatically tested. 3. Large screen, high brightness, full temperature LCD display, all measurement data displayed on one screen, with Chinese information prompts. The LCD brightness and contrast can be adjusted, and it can display clearly even in strong light. 4. The tester is equipped with a built-in micro printer that can print and output Chinese characters, allowing for direct printing of test results on site. 5. There is a protective circuit inside to prevent instrument damage and personnel accidents. 6. Adopting long-life touch buttons, the operation is simple, and most of the operations can be done using default settings with just one click. 7. The built-in high-energy power supply can complete all testing projects, and during on-site testing, the instrument does not require an external power supply or auxiliary equipment such as voltage regulators and current boosters. 8. The power-saving mode ensures the completion of field testing for multiple transformers of various models. 9. Transformer capacity testing can be conducted at non rated connection positions. 10. The test data is stable and has good repeatability. 11. The wiring is simple, and testing can be completed with only two wire clamps. There is no phase difference in the testing, and you can choose any two phases. 12. The test data can be uploaded to a PC, which can print a formal test report and form a database for management. |
| ·Performance indicators |
| 1. Capacity test: Accuracy level 0.5 within the range of 30kVA to 500kVA, Accuracy level 2 within the range of 630kVA to 16000kVA 2. Load test: Short circuit loss (copper loss): range 0-40000W, accuracy level 0.5 Impedance voltage (Uk) and its percentage (Uk%), accuracy level 0.5 3. No load test: No load loss (iron loss): range 0-40000W, accuracy level 0.5 No load current, accuracy level 0.5 4. Other electrical measurements: voltage range 0-750V, accuracy level 0.2; Current range 0-50A, accuracy level 0.2; The frequency range is 45-65Hz, with an accuracy level of 0.2. The above measurements can be completed by a self-contained power source. 5. Automatically complete temperature compensation of test data and convert the data to the rated temperature value. 6. Built in power capacity: 15AH, capable of continuously measuring over 100 transformers; Output power of 600W, can directly test large capacity transformers such as 16000KVA. 7. The instrument provides test signals: AC voltage of 40V, current of 15A, pure sine wave, distortion less than 1%. 8. Automatic determination and printing of transformer models (high energy consumption and energy-saving). 9. It has storage function and can store information of 100 transformers. 10. Equipped with short-circuit pliers for easy wiring during testing. When there are special requirements, a 1000A short-circuit plate can be optionally selected. 11. The edge resistance between the voltage and current input terminals and the machine is ≥ 500M Ω, and the working power input terminal and the casing can withstand an AC withstand voltage test of 2KV at power frequency for 1 minute. 12. The instrument has a small volume (400X320X180), light weight (less than 6 kilograms), and is easy to carry. Working environment: temperature -20~50 ℃, humidity 10%~85% |