Twelve speed rotational viscometer HTD-12S

NegotiableUpdate on 04/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Twelve speed rotational viscometer HTD-12S
Product Details

The HTD-12S digital twelve speed rotary viscometer is a new type of viscometer designed by our company. This viscometer adopts an embedded structure design, built-in high-precision angle sensor, and is driven by a stepper motor for smoother and more accurate rotation speed; The panel buttons are clearly labeled for easy operation, and the high-resolution LCD screen can display the viscosity value and stirring speed of the test liquid in real time.
This product can be widely used in industries and research institutions such as petroleum, chemical, food, medicine, cosmetics, etc.
Working principle introduction: Place the slurry cup containing the liquid to be measured on the tray, and the liquid to be measured enters the annular space (shear gap) formed between the outer sleeve and the float of the viscometer. When the stepper motor drives the outer sleeve to rotate, the sleeve is subjected to viscous resistance in the liquid to be measured, generating a reactive force. This force will generate torque on the float in the sleeve through the liquid to be measured in the annular space, and the float is connected to a set of scale components. When the torque and viscous resistance reach equilibrium, the scale component will stabilize at a certain scale value. Since the scale value is proportional to the viscous resistance of the sleeve, multiplying the scale value by a specific coefficient can obtain the final viscosity value, which will be displayed on the LCD screen for display. Read.
The shear rate and viscosity value have a linear correspondence, that is, the graph of the relationship between shear stress and shear rate is a straight line. In practical applications, many fluids may not follow Newton's laws, but their rheology is relatively close to Newton's laws, so viscosity meters can still be used for measurement, and the measured viscosity values are also relatively accurate. The calibration method of HTD-12S digital rotary viscometer is linear calibration in Newton mode, which is not applicable to the test samples that do not comply with Newton's linear calculation method. In this case, non-linear calculation methods should be used for viscosity measurement and velocity calculation.
When the outer sleeve, float, and torsion spring operate at a rate of 300 revolutions per minute, the measurement unit of the viscometer is centipoise (or millipascal per second). The data measured at other rotational speeds require a series of multiplication transformations. The sixth part of this article will provide a viscosity calculation method for pseudoplastic fluids (such as drilling fluids).
When choosing different speeds or using different combinations of torsion springs and floats, the range of available shear rates may change. To broaden the range of shear stress and measure more liquids, different torsion springs can be replaced to solve this problem.

2、 Model and specifications

HTD-12S type F1 torsion spring measuring component/F0.2 torsion spring measuring component (optional)

IIIMain technical parameters of the instrument

Name Technical parameters
Power supply AC110/220V±5% 50/60Hz
Motor Power 40W
ambient temperature ≥20±5℃
ambient humidity 45%RH~60%RH
motor speed 720 r/min
Variable speed range 1、2、3、6、10、20、30、60.100、200、300、600r/min
measurement accuracy ± 0.5 mPa. s (Newtonian fluid)
Viscosity measurement range Newtonian fluid: 0-300mPa. s (F1 measuring component)
0-60mPa. s (F0.2 measuring component)
Non Newtonian fluid: 0-150 mPa. s (F1 measuring component)
0-30 mPa. s (F0.2 measuring component)
Shear stress: 0-153.3 Pa (F1 measuring component)
0-30.7Pa (F0.2 measuring component)