Product Name:PLGseriesUPSbypass cabinet(Bypass voltage regulator)
Product Category: Stabletransformer
Capacity range:5KVA~500KVA
Product Introduction:wePengshengdaOur products are specifically designed for large factories, power plants, petrochemicals, and other industriesenterpriseUPSSupporting bypass voltage regulator. We assist in developing project plans, optimizing system solutions, and participating in the technical decomposition and import of bidding projects based on the different situations and needs of our clients.
PLG The series consists of isolation transformers (single transformer single)/Two to one/A complete backup mains bypass is composed of three transformers, voltage regulator, DC reverse diode (optional), transmitter (optional), etc.PLG The series has the characteristics of stepless voltage regulation, stable output, complete protection function, stability and reliability, easy use and maintenance, and fully meets the performance indicatorsUPSThe need for normal operation.
basic indicators
Capacity |
5KVA £65374;500KVA |
Output power factor |
0.8 |
input voltage |
380V ± 15% (two-phase or three-phase)(or customized voltage) |
output voltage |
220V ± 5% (single-phase) 380V± 5%(three(Xiang) (or customized voltage) |
voltage regulation accuracy |
Factory setting 2.5% (adjustable from 1% to 5%) |
Frequency |
50Hz/60Hz ± 2% |
protection function
Overvoltage |
Output voltage exceeding 10% of rated voltage (adjustable), with a delay of 3-5 seconds to cut off the output power supply |
Undervoltage |
Output voltage lower than 15% of rated voltage (adjustable), delay 3-5 seconds to cut off output power supply |
Short circuit |
When the load device is short circuited, cut off the output power supply |
Reverse phase |
When there is an error in the three-phase electrical phase sequence, the machine will sound an alarm and cut off the output power supply |
Lack of phase |
When there is a phase loss in three-phase electricity, the machine will sound an alarm and cut off the power supply |
Heat dissipation |
fan |
other
Additional waveform distortion |
≤ 1% |
Asymmetric degree of additional voltage |
Output to input asymmetry increment ≤ 1% |
noise |
≤ 55dB |
efficiency |
Capacity < 40KVA ≥ 94% |
Capacity 40-200KVA ≥ 98% | |
insulation class |
FGrade(otherCustomizable) |
pressure resistance |
The voltage regulator has no breakdown or arcing phenomenon at 2000VAC/min to ground |
The isolation transformer has no breakdown or arcing phenomenon at 2500VAC/min to ground | |
insulation resistance |
The whole machine has a ground resistance of ≥ 2M Ω |
Input/output cable |
Install from the front and bottom |
It can be produced according to requirements, with dimensions, color codes, wiring methods, etc. all produced according to user requirements.