UT390Multi mode ultrasonic thickness gauge
UT390The upgraded product of ultrasonic thickness gauge launched by Beijing Times New Sky Measurement and Control Technology Co., Ltd. places more emphasis on user experience and functional innovation. It adopts a 320x240 color LCD display screen, which can present clear measurement results even in low light and strong sunlight environments, greatly improving the visual experience. With an IP65 protection level, it can effectively defend against oil stains, dust, and other corrosion in harsh on-site environments; The language broadcasting measurement result function of innovative design is convenient for reading, and it can automatically alarm if it exceeds the set range, meeting the detection needs of efficient material multi-point thickness collection. It supports Bluetooth communication and has dual effects of penetrating coating mode and normal mode. Its * penetrable coating thickness measurement performance provides a more efficient solution for the detection of workpieces with paint or anti-corrosion materials on the surface. There is no need to process the coating on the workpiece surface before measurement, and it can be directly measured. It is widely used for monitoring the degree of corrosion and thinning of various pipelines and pressure vessels in production equipment in the fields of petroleum, chemical, metallurgy, shipbuilding, etc. It can also be used for measuring various plates and processed parts. It is a professional precision instrument that improves production efficiency and qualification rate, and saves costs.
Technical Specifications |
technical indicators |
|
Supports two thickness measurement modes: transmit echo mode, (0.65 -600)mm; In echo echo mode, (3~100) mm ± 0.04mm (<10mm); ± 0.4% H (>10mm); H is the thickness of the measured object 7 times per second for single point measurement and 16 times per second for scanning mode____________________________________ Color 320x240 TFT LCD screen, backlight brightness adjustable to W__________________________________________ 0.1mm/0.01mm/0.001mmswitchable (1000-9999) m/s (can measure the sound velocity of objects with known thickness) Zero point calibration, two-point calibration Single point measurement, measurement, and difference measurement____________________________________________________ Imperial system (optional) Chinese and English can be switched_________________________________________________________________ Can store and manage 100 sets of thickness data (up to 100 per set)___________________________________ Supports Bluetooth and USB 2.0 communication, and the main root sequence can be upgraded online____________________________________ Portable Bluetooth thermal printer can be used to print measurement reports________________________________________ Two AA sized alkaline batteries, capable of continuous operation for at least 30 hours (at default brightness) It has energy-saving functions such as automatic screen standby, automatic sleep mode, and automatic shutdown_______________________________ Material: ABS engineering plastic; Size: 150mmx76mmx38mm; Weight: 295g |
Feature Highlights
・It has probe zero point calibration and two-point calibration functions, and can automatically correct system errors.
working principle
UT390Ultrasonic thickness gaugeThe measurement of thickness is achieved by the probe generating ultrasonic pulses that pass through the coupling agent and reach the object being measured. Some of the ultrasonic signals are reflected by the bottom surface of the object, and the probe receives the echo reflected by the bottom surface of the object. The round-trip time of the ultrasonic waves is accurately calculated, and the thickness value is calculated according to the following formula, and then the calculation results are displayed.
In the formula:
H-measure thickness
v-Material sound velocity
t-The propagation time of ultrasonic waves back and forth in the specimen.
To ensure the normal operation of the probe, a coupling agent is required to isolate the air between the surface of the probe and the surface of the workpiece to be tested. This liquid is used for coupling between the probe and the workpiece and is called a coupling agent.
Probe selection
name |
model |
frequency |
probe diameter |
measurement range |
small diameter |
feature description |
Thickness probe |
N05 |
5MHz |
10mm |
0.65mm ~ 600mm(Steel) |
020mmx3.0mm |
General |
Thickness probe |
N05/900 |
5MHz |
10mm |
1.0mm ~ 600mm(Steel) |
020mmx3.0mm |
General |
Micro diameter probe |
N07 |
7MHz |
6mm |
0.65mm~200mm(Steel) |
cp15mmx2.0mm |
Used for measuring thin-walled and small curved surfaces |
Temperature probe |
HT5 |
5MHz |
12mm |
1.0mm-600mm(Steel) |
30mm |
Used for measuring materials with temperatures below 300 ° C |
Coarse crystal probe |
N02 |
2.5MHz 14mm |
3.0mm ~ 600mm(Steel) |
20mm |
Used for measuring coarse-grained materials such as cast iron |
|
Narrow pulse probe |
P5EE |
5MHz |
10mm |
Near echo mode: 2.0mm -600mm (steel) Echo echo mode: 3.0mm~100mm (steel) |
cp20mmx3.0mm |
Used for measuring thickness through coatings |
Instrument configuration
|
serial number 1 |
name |
host | ||
|
2 |
Narrow pulse thickness probe (P5EE) |
|
3 |
coupling agent |
standard |
4 |
ABSInstrument box |
configuration |
5 |
random data |
|
6 |
AA(Size 5) Alkaline battery |
|
7 |
USBcommunication cable |
|
8 |
Data processing software |
|
9 |
Ordinary thickness measuring probe N05 (5MHz) |
|
1 |
High temperature probe (5MHz) |
|
|
|
3 |
Coarse crystal probe 2.5MHz Produced by Beijing Times New Sky Measurement and Control Technology Co., Ltd |