E-mail
809175850@qq.com
-
Phone
13450202047
-
Address
No. 55, Yufeng 2nd Street, Dashi Street, Panyu District, Guangzhou City, Guangdong Province, China
Guangdong Hemi Instrument Co., Ltd
809175850@qq.com
13450202047
No. 55, Yufeng 2nd Street, Dashi Street, Panyu District, Guangzhou City, Guangdong Province, China
AII portable oxygen analyzer GPR-1000/1100/2000/3500 MO
AII portable oxygen analyzer GPR-1000/1100/2000/3500 MO features measurement range from 0-10 ppm to 0-99% O2, up to 5 ranges per model, with manual or automatic range change function. ATEX models can be used for IIC gas rugged design, verified for long-term on-site operation. Lightweight (2.5Kg) and easy to use. The battery can be used for up to 30 days (40 hours with pump), and the sensor life is 24 to 32 months (under normal use). Optional internal pump 0-1V is availableOutput optional XLT sensor for CO2 background gas.
AII portable oxygen analyzer GPR-1000/1100/2000/3500 MO
These sturdy and durable portable instruments are suitable for measuring trace oxygen concentrations ranging from 0.1 ppm to 99% pure oxygen, and have the same sensor technology as online process oxygen analyzers to ensure their reliability and accuracy.
The AII portable and online analyzers use the same human-machine interface and menu structure, making it very easy for operators to use these two types of instruments on site without additional training.
| GPR-1100 | GPR-1000 | GPR-2000 | GPR-3500 MO | |
| range | 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% | 0-1000 ppm, 0-1%, 0-25% | 0-1%, 0-5%, 0-10%, 0-25% | 0-99% |
| precision | Under constant conditions,<selected range='' 2%=''> | Under constant conditions,<selected range='' 2%=''> | Under constant conditions,<selected range='' 2%=''> | Under constant conditions,<selected range='' 2%=''> |
| response time | T90 < 10='' s=''> | T90 < 10='' s=''> | T90 < 10='' s=''> | T90 < 13='' s=''> |
| recovery time | 60 seconds to<10='' ppm='' under nitrogen purge=''><1='' hour=''> | 60 seconds to<100='' ppm='' under nitrogen purge=''><15='' minutes=''> | N/A | N/A |
| Sensitivity (LDL) | 0.05 ppm | 5 ppm | 0.01% | 0.10% |
| linear | <Scale='' 1%=''> | <Scale='' 1%=''> | <Scale='' 1%=''> | <Scale='' 1%=''> |
| Sensor Model | GPR-12-333 XLT-12-333 is used for gas mixtures containing>0.5% CO2 |
GPR-12-100-M XLT-12-100-M is used for gas mixtures containing>0.5% CO2 |
GPR-11-32-RTS XLT-11-24-RTS is used for gas mixtures containing>0.5% CO2 |
GPR-11-120-RTS |
| Sensor lifespan @ 25 º C (77 ° F) and 1 atm | Under<1000='' ppm='' o2=''='' 24='' months=''> | GPR-11-32-RTS in the air for 32 months XLT-11-24-RTS in the air for 24 months |
GPR-11-32-RTS in the air for 32 months XLT-11-24-RTS in the air for 24 months |
24 months under 99% O2 |
| Calibration interval | 30 days | 30 days | 30 days | 30 days |
| intake pressure | 0.34-2 barg (5-30 PSI) with vent hole | 0.34-2 barg (5-30 PSI) with vent hole | 0.34-2 barg (5-30 PSI) with vent hole | 0.34-2 barg (5-30 PSI) with vent hole |
| flow velocity | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) |
| Gas connection | 1/8 'NPT external thread quick connect | 1/8 'NPT quick connect | 1/8 'compression pipe fittings | 1/4 'compression pipe fittings |
| Liquid-contacting part | stainless steel | Brass connection; Optional stainless steel | GP version: brass, plastic ATEX version: Stainless steel flow casing, fittings and accessories |
stainless steel |
| display | Graphic LCD 7 x 3.5cm (2.75 x 1.375 ') | Graphic LCD 7 x 3.5cm (2.75 x 1.375 ') | Graphic LCD 7 x 3.5cm (2.75 x 1.375 ') | Graphic LCD 7 x 3.5cm (2.75 x 1.375 ') |
| resolution | 0.01ppm | 1ppm | 0% | 0.10% |
| shell | Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3') 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3') 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3') 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3') 3.64kg (8lbs) |
| compensation | Air pressure and temperature | Air pressure and temperature | Air pressure and temperature | Air pressure and temperature |
| signal output | 0-1V | 0-1V | 0-1V | 0-1V |
| LED indicator light | Low battery level (72 hours, warning); Charging mode | Low battery level (72 hours, warning); Charging mode | Low battery level (72 hours, warning); Charging mode | Low battery level (72 hours, warning); Charging mode |
| Operating Temperature | 5 ° C-45 ° C (41 ° F-113 ° F) (GPR sensor), -10 ° -45 ° C (14 ° F -113 ° F) (XLT sensor) |
5 ° C-45 ° C (41 ° F-113 ° F) (GPR sensor), -10 ° -45 ° C (14 ° F -113 ° F) (XLT sensor) |
5 ° C-45 ° C (41 ° F-113 ° F) (GPR sensor), -10 ° -45 ° C (14 ° F -113 ° F) (XLT sensor) |
5°C - 45°C (41°F - 113°F) |
| power supply | Rechargeable battery (lead-acid) | Rechargeable battery (lead-acid) | Rechargeable battery (lead-acid) | Rechargeable battery (lead-acid) |
| battery life | Can last up to 30 days on a full charge (with a pump running for 40 hours) | Can last up to 30 days on a full charge (with a pump running for 40 hours) | Can last up to 30 days on a full charge (with a pump running for 40 hours) | Can last up to 30 days on a full charge each time |
| Regional classification | ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C - +45°C |
ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C - +45°C |
ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C - +45°C |
For general use only |