Oxygen analyzer - Michell XTP601

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Oxygen analyzer - Michell XTP601- MCEx, UKCA, cQPSus, TR CU amp; Ex hazardous area certification type complies with IEC61508 SIL 2 certification optional range: 0-0.5% up to 0-50% amp; 20, 80 or 90-99% touch screen display, no need for hot work permit basic error (accuracy) better than 1% zero drift stability of full range, monthly output less than 0.25% of range includes RS485 and two 4-20m channels
Product Details

Oxygen analyzer - Michell XTP601

The XTP601 oxygen analyzer, which is sturdy, durable, linear, and stable, is suitable for measuring gases such as hydrogen, nitrogen, methane, biogas, or carbon dioxide. The analyzer is housed in an IP66 rated enclosure, making it suitable for a wider range of applications. XTP601 can be equipped with a flame arrester, which is explosion-proof and certified, making it suitable for use in hazardous or safe areas.

Oxygen analyzer - Michell XTP601


performance
measurement technology Thermomagnetic oxygen sensor
gas Process and non condensing sampling with solid particles<5 µ m>
range Optional 0-0.5% up to 0-50% and 20, 80 or 90-99%
display resolution 0.01% range starting from scratch
0.1% zero starting range
display type Backlit LCD
Accuracy (excluding zero free range) ± 0.02% O2 or<± 1%>
Accuracy (no zero range (80/90-99%)) ± 0.2% O2 or<± 1% range, whichever is greater=''>
Response time (T90), HSR function needs to be enabled <15='' seconds=''>
repetitiveness ± 0.2% or 0.01% O2 of the measuring range, whichever is greater
linear ± 0.5% or 0.05% O2 of the measuring range, whichever is greater
Zero stability ± 0.25% of monthly measurement range
span stability ± 0.25% of monthly measurement range
Sample gas flow rate 100 ~ 600 ml/min
The influence of sample gas flow GP1 and GP3: 100~500 ml/min (0.2~1.06 scfh)
EX1, EX3, and GP2: 270~330 ml/min (0.2~1.06 scfh)
Sample gas pressure 0.75 ~ 2 BarA
Sample gas temperature 5~+55 ° C (+45 ° C standard room)
Sampling room temperature Standard+50 ° C (optional+55 ° C and+60 ° C)
Background gas The analyzer is calibrated under the background gas of the process, with standard gases of N2, CO2, CH4, H2&biogas. Other gases can also be selected according to requirements
Electrical parameters
Analog input 2-channel 4-20 mA input
One way for external sensors, which can be displayed on the screen
Another active compensation method for process conditions
analog output 2-channel 4-20 mA output (powered by 24V excitation voltage)
output range The main scope is consistent with the calibration range of the instrument
Second user configurable range: 0-99%
call the police 2-channel single pole conversion (SPCO) relay numerical alarm (250 V, 5 A)
data recording Users can collect the output signals of the analyzer through digital communication
Can store the minimum value of 40 alarm points and oxygen content readings, all with date and time explanations
Digital Communication MODBUS RTU based on RS485 protocol
power supply 24 V DC; 1.5 A
cable entry The analyzer is equipped with 3 x M20 cable entrances. Cable connectors, conduit entrances, and plugs are provided as accessories
working environment
ambient temperature 5 ~ +55°C
atmospheric pressure 750mbar ~ 1250mbar
mechanical parameters
warm-up time <25 minutes=''>
stabilization time 5 minutes
size 234 x 234 x 172mm (w x d x h)
weight 9.7kg
wetted material 316&430F stainless steel, silicone glass, platinum, 3M 2216, O-ring
O-ring material Fluororubber, silicone or Ekraz
Gas connection EX1, EX3&GP2: 1/8 'NPT (internal thread)
GP1 and GP3: 1/4 'NPT (internal thread)
Protection level IP66, NEMA 4X
Hazardous Area Certification
ATEX/UKCA II 2GD Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
IECEx Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
Temperature range of each O-ring type under ATEX/UKCA and IECEx Silicone: Ta O-ring=-40 ° C~+60 ° C (North American temperature+50 ℃)
fluororubber ®: Ta O-ring=-15 ° C~+60 ° C (North American temperature+50 ℃)
Ekraz: Ta O-ring=-10 ° C~+60 ° C (North American temperature+50 ℃)
cQPSus Class I, Division 1, Groups B,C,D, T6
TR CU Ex 1 Ex d IIB+H2 T6 Gb