NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Panametrics LCT8 high-precision ultrasonic flowmeter adopts the groundbreaking Sentinel LCT4 design, which can be seamlessly integrated into pipelines or processes. When smaller installation footprint is required or pressure drop is considered, the eight way design allows for shorter upstream and downstream lengths. LCT8 uses many proprietary algorithms to reduce viscosity effects, making it unaffected by viscosity. When viscosity changes, there is no need to prove operation or change settings. The instrument maintains its accuracy throughout the entire range of minimum and maximum viscosity, using only one calibration curve.
Product Details

Panametrics LCT8 high-precision ultrasonic flowmeter

Compared with other flow meters, LCT8 fully embodies the advantages of ultrasonic flow measurement, including:

No drift or need for regular calibration

• No pressure drop • Unrestricted pipeline

• No moving parts, no filters or screens

Specifications

Operation and performance

fluid type

Liquid hydrocarbons, crude oil and refined oil, other liquids

flow measurement

Related transit time patterns

precision

When the flow rate is between 1 and 33 feet per second (0.3 to 10 m/s), the measured volume is less than ± 0.15% (the extension range can be provided upon request)

repetitiveness

±0.02%

Viscosity range

For higher viscosity values from 0 to 6600 cSt, please consult the factory

Renault range

> Re 5, 000, consult the factory to obtain a lower Reynolds number

process temperature

-40 to+140 ° C (-40 to+248 ° F)

ambient temperature

-40 ° to+60 ° C (-40 ° to 140 ° F)

Storage temperature

-40 ° to+85 ° C (-40 ° to+176 ° F)

power supply

• 100 to 240 VAC • 12 to 32 VDC

display

High contrast 128 x 64 pixel graphic display with LED lighting.

output

Two frequency/pulse outputs, isolated from DC electro-optical

Two alarm relays

• A 4/20 mA output

input

Two 4/20 mA and one 100 ohm RTD input for temperature, pressure, and density inputs (optional).

Three 4/20 mA inputs for temperature, pressure, and density inputs (optional)

Digital interface

• PanaLink via RS232/485/USB

Modbus RTU on RS232/485


Panametrics LCT8 high-precision ultrasonic flowmeter

application

• Pipeline leak detection

• Liquid liquid transfer measurement

• Allocate metrics