Welcome Customer !

Membership

Help

Guangdong Hemi Instrument Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Guangdong Hemi Instrument Co., Ltd

  • E-mail

    809175850@qq.com

  • Phone

    13450202047

  • Address

    No. 55, Yufeng 2nd Street, Dashi Street, Panyu District, Guangzhou City, Guangdong Province, China

Contact Now

GE Panametrics liquid ultrasonic flowmeter

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
GE Panametrics liquid ultrasonic flowmeter is a SIL certified flowmeter suitable for measuring liquid flow at nominal temperature or high/low temperature conditions. As an ultrasonic flowmeter certified with SIL (Safety Integrity Level), this equipment is specifically designed for safety critical applications such as coking plant flow meters. Its reliability can effectively reduce the risks of personnel injury, equipment asset loss, environmental pollution, and damage to corporate reputation. Meanwhile, this device can also play an important role in any non safety critical application scenario that requires reliable ultrasonic flow measurement.
Product Details

GE Panametrics liquid ultrasonic flowmeter

Features and advantages

• Driftless flow measurement

No need for regular calibration

• No maintenance required

• Unrestricted pipeline

Design reliable measurement - (IEC61508 certification)

• Flow measurement in applications with high process temperatures (600 ° C/1112 ° F)

• Flow measurement in applications with extremely low process temperatures (-200 ° C/-328 ° F)

• Bidirectional measurement

GE Panametrics liquid ultrasonic flowmeter

Product Specifications

Fluid type

Liquid: Acoustic conductive liquid, including most cleaning liquids, as well as liquids containing small amounts of entrained solids or bubbles

Flow measurement

Related transmission time ™ Mode

size

3 inches to 16 inches (80 millimeters to 600 millimeters) standard optional: 72 inches (1800 millimeters) size available upon request

precision

Meter scale with a reading of ± 0.5% 3 to 4 inches (80 to 100 millimeters)

Range: Metric sizes ranging from 7 to 40 feet per second (2.13 to 12.19 meters per second) and 6 inches to 36 inches (150 to 900 millimeters)

Range: 3 to 40 feet per second (0.91 to 12.19 meters per second) ± 0.9% reading 3 to 4 inches (80 millimeters to 100 millimeters) metric size

Range: 3 to 7 feet per second (0.91 to 2.13 meters per second). The final installation must meet the following conditions: the fluid flow profile has been formed (usually at 10 times the diameter upstream and 5 times the diameter downstream of the straight pipe section), and the fluid is a single-phase fluid. Applications that use pipeline layout to generate eddy currents (such as two out of plane elbows) may require additional straight pipe sections or flow control devices. Larger sized instruments can be provided upon request.

Repeatability

Reading ± 0.25% for metric dimensions of 3 to 4 inches (80 to 100 millimeters), range: 7 to 40 feet per second (2.13 to 12.19 meters per second) for metric dimensions of 6 to 36 inches (150 to 900 millimeters), range: 3 to 40 feet per second (0.91 to 12.19 meters per second), reading ± 0.5% for metric dimensions of 3 to 4 inches (80 to 100 millimeters), range: 3 to 7 feet per second (0.91 to 2.13 meters per second)

Scope (bidirectional)

0.1 to 40 feet per second (0.03 to 12.19 m/s)

Variability (overall)

400:1

Sensor systems and materials

Bundle Waveguide Technology ™ (BWT) System probe and bracket made of 316L stainless steel are optional: alternative cushioning materials can be provided upon request

Sensor temperature range

Normal temperature: -310 ° F to 600 ° F (-190 ° C to 315 ° C) liquid

High temperature: -310 ° F to 1112 ° F (-190 ° C to 600 ° C)

application

• Coking crude oil distillation

• Vacuum distillation

• Fragments

• Water treatment equipment