The GR-NH3-N (conductivity method) ammonia nitrogen water quality online automatic monitoring instrument consists of a sampling system, a metering system, a digestion system, an absorption system, a detection system, and a programmable control system. The monitoring device collects water samples through an automatic sampling system, and after passing through a high-precision photoelectric sensing measurement system, the water samples are transported to the digestion system. The digestion system automatically adds a set amount of digestion solution, and after high-temperature digestion, ammonia gas is blown out. Add a certain amount of absorption solution to the absorption system to absorb the ammonia gas blown out. The detection system detects the electromotive force at both ends of the electrode, and the automatic controller system calculates the concentration value of ammonia nitrogen.
Can achieve the functions of standard sample verification and spiked recovery;
Capable of remote transmission control, bidirectional communication, and other functions;
Total amount of liquid for a single sample<8>8>
Equipped with automatic protection and cleaning functions for power and water outages;
Equipped with measurement over limit alarm function, supporting remote setting of over limit values;
Adopting high-resolution color touch screen, easy to operate and rich in information;
High precision infrared visible photoelectric non-contact measurement system, with high measurement accuracy and high operational reliability;
Through independently designed sampling pipelines, there are independent pipelines for sampling, quantification, liquid discharge, and each reagent,
Avoid measurement errors caused by pollution.
project |
Technical Requirements |
analytical method |
electrochemical method |
measurement range |
0 - 4mg/L, Segmentable, expandable, and customizable |
zero drift |
≤±0.02mg/L |
Span Drift |
≤±5% |
Minimum detection limit |
0.1 mg/L |
Resolution |
0.01mg/L |
accuracy |
≤±3% |
repetitiveness |
≤2% |
spike recovery rate |
90%-110% |
measurement period |
Minimum measurement cycle of 20 minutes |
Measurement Mode |
(1min~9999min) Any adjustable time interval mode and hourly measurement mode |
calibration cycle |
(1 day to 99 days) Adjustable at any interval and any time |
maintenance cycle |
Usually once a month, about 30 minutes each time |
signal output |
RS-485 digital and 4-20mA analog output |
human-computer interaction |
HMI high-resolution color touch screen Chinese interface command input |
external power supply |
220VAC,50Hz,5A |
environmental adaptability |
Temperature (0-40) ℃; Humidity ≤ 90% (non condensing) |
Overall dimensions |
310mm*254mm*524mm |