Breast X-ray tissue equivalent phantom

NegotiableUpdate on 02/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
CIRS 011A breast phantom, CIRS 011A breast X-ray tissue equivalent phantom, is a recommended breast imaging quality evaluation model by the American Cancer Society and the School of Radiology
Product Details




CIRS 011A breast phantom, CIRS 011ABreast X-ray tissue equivalent phantomdescription
CIRS 011A breast phantom, CIRS 011A breast X-ray tissue equivalent phantom, is a recommended breast imaging quality evaluation model by the American Cancer Society and the School of Radiology

Providing a sophisticated quality assurance tool for today's advanced imaging systems.

The validated simulation technology of CIRS 011A breast phantom can make tissues equivalent and provide a realistic model for quality assurance in mammography.

Resin materials mimic the photon attenuation coefficients of a series of breast tissues. The average elemental composition of the imitated human breast is based on the individual elemental composition of fat and glandular tissue reported by Hammerstein.

The attenuation coefficient is calculated using JHHubbell's "mixing rule" and the photon mass attenuation and energy absorption coefficient table.

The CIRS 011A breast phantom contains targets aimed at testing the threshold of the new generation of mammography machines. 4.5 centimeters thick, and simulate the average glandular tissue composition.

Intended to test the performance of any mammography system. The objects in the model simulate calcification, including fibrous calcification in ducts and tumor masses. The range of testing objects within the body range should be from objects that should be visible on any system to objects that are difficult to solve on the most advanced mammography system.

乳腺X射线组织等效模体
乳腺X射线组织等效模体

乳腺X射线组织等效模体
CIRS 011A breast phantom, CIRS 011A breast X-ray tissue equivalent phantom technical parameters:
1. Line to line details 1) 20 lp/mm 2 sets of horizontal and vertical layout

2. Calcium carbonate lesion points 2) 0.13 3) 0.165 4) 0.196 5) 0.23 6) 0.275 7) 0.4 8) 0.23 9) 0.196 10) 0.165 11) 0.23 12) 0.196 13) 0.165

3. Step wedge block (1cm) 14) 100% glandular tissue 15) 70% glandular tissue 16) 50% glandular tissue 17) 30% glandular tissue 18) 100% adipose tissue

4. Nylon fiber 19) 1.25mm 20) 0.83mm 21) 0.71mm 22) 0.53mm 23) 0.3mm

5. Hemispherical mass (75% glandular tissue, 25% fat) 24) Thickness 4.76mm 25) Thickness 3.16mm 26) Thickness 2.38mm 27) Thickness 1.98mm 28) Thickness 1.59mm 29) Thickness 1.19mm 30) Thickness 0.9mm

6. Optical Density 31) Reference Zone

7. Wiring harness boundary 32) Positioning details



CIRS 011A breast phantom, CIRS 011A breast X-ray tissue equivalent phantom physical shooting image:

乳腺X射线组织等效模体

乳腺X射线组织等效模体

乳腺X射线组织等效模体