GL-200A COD analyzer, the principle of the measurement project conforms to the recognized methods in the environmental protection industry. The colorimetric method adopts tube colorimetry, which can quickly determine the concentration of COD in water quality without transferring the liquid to the colorimetric dish. It is equipped with a micro thermal printer, and the data can be printed after detection. The test data can be exported through a USB flash drive. The device is equipped with the "Glos Water Quality Intelligent Detection System" to make detection simple and intelligent.
Product Overview
GL-200ACOD analyzerThe principle of the testing project conforms to the recognized methods in the environmental protection industry. The colorimetric method adopts tube colorimetry, which can quickly determine the concentrations of COD, ammonia nitrogen, total phosphorus, and total nitrogen in water quality without transferring to a colorimetric dish. It is equipped with a micro thermal printer, and the data can be printed after detection. The test data can be exported through a USB flash drive.GL-200ACOD analyzer,The equipment is equipped with the "Glos Water Quality Intelligent Detection System" technology, making detection simple and intelligent. The product has built-in applications such as water quality analysis, data query, and guided detection mode. Widely used in scientific research, universities, sewage treatment plants, water environment testing, enterprise sewage self inspection and other fields.
Product Overview
Widely used in scientific research, universities, sewage treatment plants, water environment testing, enterprise sewage self inspection and other fields.
detection parameters
testing indicators |
COD |
measurement standard |
HJ/T399-2007 |
Detection range |
0-15000mg/L (segmented) |
detection limit |
5mg/L |
Anti chlorine interference |
2000mg/L |
Dissolving temperature |
165℃,20min |
indication error |
COD≤50mg/L,±4mg/L; COD>50mg/L, 误差≤ ± 5% |
Measurement time |
25 minutes/batch |
Features
01 |
|
Adopting a solid-state cold light source with a lifespan of 100000 hours and stable performance. |
02 |
|
Support the determination of four water quality pollutants: COD, ammonia nitrogen, total phosphorus, and total nitrogen. |
03 |
|
4.3-inch color screen display, guided operation, allowing users to easily complete concentration measurements. |
04 |
|
Equipped with the self-developed Glos water quality intelligent detection system, making detection simpler and more intelligent. |
05 |
|
Built in thermal printer, supports automatic printing and batch printing. |
06 |
|
Paired with support for (16mm) tube color comparison, digestion does not require the removal of liquid. |
07 |
|
The integrated design of digestion and colorimetry eliminates the need for a colorimetric dish for detection, making it more efficient. |
08 |
|
ABS material, high-strength, corrosion-resistant, and high-temperature resistant shell. |
09 |
|
Measurement data can be exported by inserting a USB flash drive. |
10 |
|
Equipped with G7 digestion instrument as standard, only one click is needed to complete the digestion operation of the project. |
11 |
|
Equipped with customized pipettes, reducing errors in water sample collection and ensuring greater stability. |
12 |
|
Equipped with factory pre made reagents and consumables, there is no need to repeatedly transfer and prepare concentrated sulfuric acid. Only water quality samples need to be added to the test tube for testing. |
technical indicators
indication error |
≤± 5% |
repetitiveness |
≤± 3% |
Optical stability |
≤± 0.003Abs/20 minutes (100000 hours lifespan) |
Colorimetric method |
16mm colorimetric tube (no need for pipetting for digestion) |
printer |
Micro thermal printer |
operating system |
Equipped with Glos water quality intelligent detection system |
screen display |
4.3-inch high-definition color screen |
Device Function |
Water quality analysis, photometric measurement, data management, USB data export. |
Shell material |
Abs |
Instrument power supply |
DC 12V,5A |
working environment |
5-40 ℃, ≤ 85% non condensing |
instrument size |
300mm×222mm×88mm |
Instrument weight |
About 2.8kg |
The following projects support customization
serial number |
Test Item |
Range (expandable) |
detection limit |
Testing Standard |
01 |
COD |
0-15000mg/L |
5mg/L |
HJ/T 399-2007 |
02 |
Ammonia nitrogen Nessler |
0-50mg/L |
0.05mg/L |
HJ535-2009 |
03 |
Ammonia nitrogen salicylic acid |
0-10mg/L |
0.01mg/L |
HJ536-2009 |
04 |
Total Phosphorus |
0-16mg/L |
0.02mg/L |
GB/T 11893-1989 |
05 |
Total phosphorus vanadium molybdenum yellow |
0-30mg/L |
0.2mg/L |
Vanadium molybdenum yellow spectrophotometric method |
06 |
Total Nitrogen |
0-250mg/L |
0.05mg/L |
Alkaline persulfate digestion photometric method |
07 |
*Total nitrogen |
0-150mg/L |
0.05mg/L |
(Applicable only to 820) HJ 636-2012 |
08 |
chroma |
0-500PCU |
5PCU |
GB/T 11903-1989 |
09 |
turbidity |
0-100NTU |
1NTU |
GB/T 13200-1991 |
10 |
suspended solids |
0-500mg/L |
1mg/L |
GB 11901-1989 Improvement |
11 |
Copper BCO |
0-1mg/L |
0.04mg/L |
Dicyclohexanone Oxalidomide Dihydrazide spectrophotometric method |
12 |
Copper bis quinoline |
0-5mg/L |
0.1mg/L |
GB/T 223.91-2021 |
13 |
*Copper |
5-75ug/L |
5pg/L |
(Boiler water microgram level) |
14 |
Nickel - ultra-low |
0-1mg/L |
0.002mg/L |
PAN spectrophotometric method |
15 |
Nickel - National Standard |
0-4mg/L |
0.1mg/L |
GB 11910-89 |
16 |
Iron PHEN |
0-5mg/L |
0.02mg/L |
HJ/T345-2007 |
17 |
*Iron |
0-200ug/L |
10ug/L |
(Boiler water microgram level) |
18 |
Zinc Zinc Reagent |
0-4mg/L |
0.2mg/L |
GB/T 10656-2022 |
19 |
hexavalent chromium |
0-1mg/L |
0.01mg/L |
GB7467-87 |
20 |
Total chromium |
0-1mg/L |
0.01mg/L |
GB7466-87 |
21 |
Cobalt PAN |
0-2mg/L |
0.02mg/L |
PAN spectrophotometric method |
22 |
Cobalt - National Standard |
0-0.5mg/L |
0.01mg/L |
HJ 550-2015 |
23 |
Manganese high iodine potassium |
0-16mg/L |
0.02mg/L |
GB 11906-1989 |
24 |
Manganese formaldehyde oxime |
0-6mg/L |
0.025mg/L |
HJ/T 344-2007 |
25 |
Permanganate index |
0.5-5mg/L |
0.25mg/L |
Direct spectrophotometry GB11892-89 |
26 |
Permanganate index |
0.1-4.5mg/L |
0.25mg/L |
Chlorine resistant spectrophotometry GB11892-89 |
27 |
aniline |
0-3mg/L |
0.03mg/L |
GB11892-89 |
28 |
sulfide |
0-1mg/L |
0.01mg/L |
HJ 1226-2021 |
29 |
volatile phenol |
0-2mg/L |
0.01mg/L |
HJ503-2009 |
30 |
Qing chemical compound |
0-0.5mg/L |
0.01mg/L |
HJ484-2009 |
31 |
fluoride |
0-1.6mg/L |
0.02mg/L |
HJ 488-2009 |
32 |
chloride |
0-15mg/L |
0.1mg/L |
Sulfuric acid mercury spectrophotometric method |
33 |
silicon dioxide |
0-5mg/L |
0.01mg/L |
GB/T 12149-2017 |
34 |
residual chlorine |
0-3mg/L |
0.02mg/L |
HJ 586-2010 |
35 |
Total residual chlorine |
0-3mg/L |
0.02mg/L |
HJ 586-2010 |
36 |
Chlorine dioxide |
0-5mg/L |
0.05mg/L |
GB/T 5750.11-2023 On site DPD method |
37 |
nitrite |
0-0.2mg/L |
0.003mg/L |
GB7493-87 |
38 |
Thiocyanate salt |
0-20mg/L |
0.2mg/L |
HG/T 6072-2022 |
39 |
Nitrate nitrogen |
0-20mg/L |
0.1mg/L |
Color changing acid spectrophotometric method |
40 |
phosphate |
0-1.6mg/L |
0.02mg/L |
GB 11893-89 |
41 |
Phosphate Vanadium Molybdenum Yellow |
0-30mg/L |
0.2mg/L |
Vanadium molybdenum yellow spectrophotometric method |
42 |
sulfate |
8-200mg/L |
2mg/L |
HJ/T342-2007 |
43 |
Anionic surfactant |
0-2mg/L |
0.02mg/L |
GB/T7494-87 |
44 |
Formaldehyde in water |
0-3mg/L |
0.05mg/L |
Acetylacetone HJ 601-2011 |
45 |
ozone |
0-1mg/L |
0.01mg/L |
GB/T 5750.11-2023 |
46 |
hydrogen peroxide |
0-50mg/L |
0.5mg/L |
GB5009.226-2016 |
47 |
Total alkalinity |
0-300mg/L |
5.0mg/L |
Spectrophotometry |
48 |
Total Hardness |
0-100mg/L |
5.0mg/L |
Spectrophotometry |
49 |
urea |
0-10mg/L |
0.1mg/L |
GB/T18204.2-2014 |
50 |
Cyanuric acid |
5-50mg/L |
5.0mg/L |
CJ244-2007 |
51 |
Volatile fatty acids |
0-60mmoL/L |
0.5mmoL/L |
High-speed railway photometry |
52 |
calcium |
5-100mg/L |
5mg/L |
O-cresol tai complex ketone photometric method |
53 |
magnesium |
5-100mg/L |
5mg/L |
GB/T 6900-2006 |
54 |
silver |
0-0.7mg/L |
0.02mg/L |
HJ 489-2009 |
55 |
lead |
0-6mg/L |
0.1mg/L |
GB/T 223.29-2008 |
56 |
aluminium |
0-0.25mg/L |
0.005mg/L |
GB/T 5750-2023 |
serial number |
Gas series |
Range (expandable) |
detection limit |
Testing Standard |
57 |
ammonia |
0-25ug |
0.4ug |
《HJ533-2009》《GBZ/T 160.29-2004》 |
58 |
sulfur dioxide |
0-12ug |
0.12ug |
《HJ482-2009 》《GBZ/T 160.33-2004》 |
59 |
Air formaldehyde |
0-5ug |
0.02ug |
《GB/T 18204.2-2014 》 |
60 |
hydrogen sulfide |
0-5ug |
0.05ug |
Yajia Blue spectrophotometric method "GBZ/T 160.33-2004 |
61 |
hydrogen chloride |
0-40ug |
1.6ug |
《HJ-T27-1999》《GBZ/T 160.37-2004 》 |
62 |
chlorine gas |
0-8ug |
0.08ug |
《HJ533-2009》《GBZ/T 160.37-2004 》 |