Welcome Customer !

Membership

Help

Shandong Greencairui Precision Instrument Co., Ltd. (Headquarters)
Custom manufacturer

Main Products:

cep-online>Products

Shandong Greencairui Precision Instrument Co., Ltd. (Headquarters)

  • E-mail

    glcncod@163.com

  • Phone

    16658935030

  • Address

    Building E7-1 and E10-2, Jiuwei Industrial Park, Zhonghua West Road, High tech Zone, Heze City, Shandong Province

Contact Now

COD analyzer

NegotiableUpdate on 04/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
GL-200A COD analyzer, the principle of the measurement project conforms to the recognized methods in the environmental protection industry. The colorimetric method adopts tube colorimetry, which can quickly determine the concentration of COD in water quality without transferring the liquid to the colorimetric dish. It is equipped with a micro thermal printer, and the data can be printed after detection. The test data can be exported through a USB flash drive. The device is equipped with the "Glos Water Quality Intelligent Detection System" to make detection simple and intelligent.
Product Details

Product Overview


GL-200ACOD analyzerThe principle of the testing project conforms to the recognized methods in the environmental protection industry. The colorimetric method adopts tube colorimetry, which can quickly determine the concentrations of COD, ammonia nitrogen, total phosphorus, and total nitrogen in water quality without transferring to a colorimetric dish. It is equipped with a micro thermal printer, and the data can be printed after detection. The test data can be exported through a USB flash drive.GL-200ACOD analyzerThe equipment is equipped with the "Glos Water Quality Intelligent Detection System" technology, making detection simple and intelligent. The product has built-in applications such as water quality analysis, data query, and guided detection mode. Widely used in scientific research, universities, sewage treatment plants, water environment testing, enterprise sewage self inspection and other fields.


Product Overview


Widely used in scientific research, universities, sewage treatment plants, water environment testing, enterprise sewage self inspection and other fields.


detection parameters


testing indicators

COD

measurement standard

HJ/T399-2007

Detection range

0-15000mg/L (segmented)

detection limit

5mg/L

Anti chlorine interference

2000mg/L

Dissolving temperature

165℃,20min

indication error

COD≤50mg/L,±4mg/L; COD>50mg/L, 误差≤ ± 5%

Measurement time

25 minutes/batch


Features


01


Adopting a solid-state cold light source with a lifespan of 100000 hours and stable performance.

02


Support the determination of four water quality pollutants: COD, ammonia nitrogen, total phosphorus, and total nitrogen.

03


4.3-inch color screen display, guided operation, allowing users to easily complete concentration measurements.

04


Equipped with the self-developed Glos water quality intelligent detection system, making detection simpler and more intelligent.

05


Built in thermal printer, supports automatic printing and batch printing.

06


Paired with support for (16mm) tube color comparison, digestion does not require the removal of liquid.

07


The integrated design of digestion and colorimetry eliminates the need for a colorimetric dish for detection, making it more efficient.

08


ABS material, high-strength, corrosion-resistant, and high-temperature resistant shell.

09


Measurement data can be exported by inserting a USB flash drive.

10


Equipped with G7 digestion instrument as standard, only one click is needed to complete the digestion operation of the project.

11


Equipped with customized pipettes, reducing errors in water sample collection and ensuring greater stability.

12


Equipped with factory pre made reagents and consumables, there is no need to repeatedly transfer and prepare concentrated sulfuric acid. Only water quality samples need to be added to the test tube for testing.


technical indicators


indication error

≤± 5%

repetitiveness

≤± 3%

Optical stability

≤± 0.003Abs/20 minutes (100000 hours lifespan)

Colorimetric method

16mm colorimetric tube (no need for pipetting for digestion)

printer

Micro thermal printer

operating system

Equipped with Glos water quality intelligent detection system

screen display

4.3-inch high-definition color screen

Device Function

Water quality analysis, photometric measurement, data management, USB data export.

Shell material

Abs

Instrument power supply

DC 12V,5A

working environment

5-40 ℃, ≤ 85% non condensing

instrument size

300mm×222mm×88mm

Instrument weight

About 2.8kg



The following projects support customization


serial number

Test Item

Range (expandable)

detection limit

Testing Standard

01

COD

0-15000mg/L

5mg/L

HJ/T 399-2007

02

Ammonia nitrogen Nessler

0-50mg/L

0.05mg/L

HJ535-2009

03

Ammonia nitrogen salicylic acid

0-10mg/L

0.01mg/L

HJ536-2009

04

Total Phosphorus

0-16mg/L

0.02mg/L

GB/T 11893-1989

05

Total phosphorus vanadium molybdenum yellow

0-30mg/L

0.2mg/L

Vanadium molybdenum yellow spectrophotometric method

06

Total Nitrogen

0-250mg/L

0.05mg/L

Alkaline persulfate digestion photometric method

07

*Total nitrogen

0-150mg/L

0.05mg/L

(Applicable only to 820) HJ 636-2012

08

chroma

0-500PCU

5PCU

GB/T 11903-1989

09

turbidity

0-100NTU

1NTU

GB/T 13200-1991

10

suspended solids

0-500mg/L

1mg/L

GB 11901-1989 Improvement

11

Copper BCO

0-1mg/L

0.04mg/L

Dicyclohexanone Oxalidomide Dihydrazide spectrophotometric method

12

Copper bis quinoline

0-5mg/L

0.1mg/L

GB/T 223.91-2021

13

*Copper

5-75ug/L

5pg/L

(Boiler water microgram level)

14

Nickel - ultra-low

0-1mg/L

0.002mg/L

PAN spectrophotometric method

15

Nickel - National Standard

0-4mg/L

0.1mg/L

GB 11910-89

16

Iron PHEN

0-5mg/L

0.02mg/L

HJ/T345-2007

17

*Iron

0-200ug/L

10ug/L

(Boiler water microgram level)

18

Zinc Zinc Reagent

0-4mg/L

0.2mg/L

GB/T 10656-2022

19

hexavalent chromium

0-1mg/L

0.01mg/L

GB7467-87

20

Total chromium

0-1mg/L

0.01mg/L

GB7466-87

21

Cobalt PAN

0-2mg/L

0.02mg/L

PAN spectrophotometric method

22

Cobalt - National Standard

0-0.5mg/L

0.01mg/L

HJ 550-2015

23

Manganese high iodine potassium

0-16mg/L

0.02mg/L

GB 11906-1989

24

Manganese formaldehyde oxime

0-6mg/L

0.025mg/L

HJ/T 344-2007

25

Permanganate index

0.5-5mg/L

0.25mg/L

Direct spectrophotometry GB11892-89

26

Permanganate index

0.1-4.5mg/L

0.25mg/L

Chlorine resistant spectrophotometry GB11892-89

27

aniline

0-3mg/L

0.03mg/L

GB11892-89

28

sulfide

0-1mg/L

0.01mg/L

HJ 1226-2021

29

volatile phenol

0-2mg/L

0.01mg/L

HJ503-2009

30

Qing chemical compound

0-0.5mg/L

0.01mg/L

HJ484-2009

31

fluoride

0-1.6mg/L

0.02mg/L

HJ 488-2009

32

chloride

0-15mg/L

0.1mg/L

Sulfuric acid mercury spectrophotometric method

33

silicon dioxide

0-5mg/L

0.01mg/L

GB/T 12149-2017

34

residual chlorine

0-3mg/L

0.02mg/L

HJ 586-2010

35

Total residual chlorine

0-3mg/L

0.02mg/L

HJ 586-2010

36

Chlorine dioxide

0-5mg/L

0.05mg/L

GB/T 5750.11-2023 On site DPD method

37

nitrite

0-0.2mg/L

0.003mg/L

GB7493-87

38

Thiocyanate salt

0-20mg/L

0.2mg/L

HG/T 6072-2022

39

Nitrate nitrogen

0-20mg/L

0.1mg/L

Color changing acid spectrophotometric method

40

phosphate

0-1.6mg/L

0.02mg/L

GB 11893-89

41

Phosphate Vanadium Molybdenum Yellow

0-30mg/L

0.2mg/L

Vanadium molybdenum yellow spectrophotometric method

42

sulfate

8-200mg/L

2mg/L

HJ/T342-2007

43

Anionic surfactant

0-2mg/L

0.02mg/L

GB/T7494-87

44

Formaldehyde in water

0-3mg/L

0.05mg/L

Acetylacetone HJ 601-2011

45

ozone

0-1mg/L

0.01mg/L

GB/T 5750.11-2023

46

hydrogen peroxide

0-50mg/L

0.5mg/L

GB5009.226-2016

47

Total alkalinity

0-300mg/L

5.0mg/L

Spectrophotometry

48

Total Hardness

0-100mg/L

5.0mg/L

Spectrophotometry

49

urea

0-10mg/L

0.1mg/L

GB/T18204.2-2014

50

Cyanuric acid

5-50mg/L

5.0mg/L

CJ244-2007

51

Volatile fatty acids

0-60mmoL/L

0.5mmoL/L

High-speed railway photometry

52

calcium

5-100mg/L

5mg/L

O-cresol tai complex ketone photometric method

53

magnesium

5-100mg/L

5mg/L

GB/T 6900-2006

54

silver

0-0.7mg/L

0.02mg/L

HJ 489-2009

55

lead

0-6mg/L

0.1mg/L

GB/T 223.29-2008

56

aluminium

0-0.25mg/L

0.005mg/L

GB/T 5750-2023

serial number

Gas series

Range (expandable)

detection limit

Testing Standard

57

ammonia

0-25ug

0.4ug

《HJ533-2009》《GBZ/T 160.29-2004》

58

sulfur dioxide

0-12ug

0.12ug

《HJ482-2009 》《GBZ/T 160.33-2004》

59

Air formaldehyde

0-5ug

0.02ug

《GB/T 18204.2-2014 》

60

hydrogen sulfide

0-5ug

0.05ug

Yajia Blue spectrophotometric method "GBZ/T 160.33-2004

61

hydrogen chloride

0-40ug

1.6ug

《HJ-T27-1999》《GBZ/T 160.37-2004 》

62

chlorine gas

0-8ug

0.08ug

《HJ533-2009》《GBZ/T 160.37-2004 》