The GL-4800 controller is a universal multi parameter water quality online monitoring device that can simultaneously connect multiple optical and electrochemical sensors, display real-time measurement values and sensor status, calibrate and calibrate sensors, and has functions such as data storage and transmission. The controller interface is simple and easy to operate, and even non professionals can quickly get started using it.
Product Overview
GL-4800 controller is a universal typeMulti parameter water quality online monitoring instrument,It can simultaneously connect multiple optical sensors and electrochemical sensors, display real-time measurement values and sensor status, calibrate and calibrate sensors, and has functions such as data storage and transmission.Multi parameter water quality online monitoring instrumentThe controller interface is simple and easy to operate, and even non professionals can quickly get started using it.
Application field
Widely used for monitoring enterprise wastewater, domestic wastewater, and surface water in industries, agriculture, scientific research, environmental protection, and other fields.
Features
01 |
|
Digital intelligent sensors can be combined arbitrarily, plug and play, and the controller automatically recognizes them. |
02 |
|
It can be customized to be used as a single parameter, dual parameter, or multi parameter controller for better cost savings. |
03 |
|
Automatically read the internal calibration records of the sensor, replacing the sensor does not require calibration, which saves more time. |
04 |
|
The circuit design adopts industrial grade standards, with output isolation, extremely low failure rate, and strong anti-interference ability. |
05 |
|
IP65 protection level, suitable for various indoor and outdoor installation requirements. |
06 |
|
7-inch color touch screen, Chinese operation interface, easy to operate. |
07 |
|
It has data storage, viewing, and export functions, and can set its own storage period. |
08 |
|
output signal RS485 Modbus RTU standard protocol. |
technical indicators
display interface |
7-inch color touch screen, LED backlight |
historical data |
It has data storage, viewing, and export functions, and can set its own storage period10 years of data |
divide distinguish rate |
800*480 |
Shell material |
ABS |
Output function |
RS485 Modbus RTU standard protocol, supports 4-20mA signal output, water tank control signal, and liquid level monitoring. |
Overall dimensions |
235*185*117mm |
Protection level |
IP65 rating |
Working Voltage |
100~240VAC or 24VDC customization |
measurement items |
Simultaneous measurement and displaypH、ORP、 Turbidity, chromaticity, residual chlorine, chloride ions, dissolved oxygen, transparency, conductivity, nitrate
Temperature, suspended solids, sludge concentration, chlorophyll, blue-green algaeCOD、 Ammonia nitrogen, fluoride ions, and oil in water can be used simultaneously at mostchoice
20 testing items.
|
Test Item
Test Item |
COD |
working principle |
UV absorption method |
measurement range |
(0-500,500-1000)mg/L |
resolution |
0.1mg/L |
measurement accuracy |
±10% |
linear error |
<5% |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
ammonia nitrogen |
working principle |
ion selective electrode |
measurement range |
(0.2-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
10% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
PH |
working principle |
Glass electrode method |
measurement range |
(0-14)pH |
resolution |
0.01pH |
sensitivity |
(57-59)mV/pH |
measurement accuracy |
<0.1pH |
response time |
<15s |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
ORP |
measurement range |
-999~999mV |
measurement accuracy |
±20mV |
resolution |
1mV |
temperature range |
0~50 ℃ (non freezing) |
Specifications and Dimensions |
D28mm,L194mm, 10-meter line |
material |
POM+titanium alloy |
|
|
Test Item |
chroma |
working principle |
Optical absorption method |
Measure wavelength |
470nm,546nm |
measurement range |
(0-500)Hazen,(0-500)NTU |
measurement accuracy |
±2%FS |
resolution |
0.5Hazen |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
turbidity |
working principle |
light scattering method |
measurement range |
(0-4,000)NTU |
resolution |
0.1NTU |
repetitiveness |
<5% |
Straightness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
residual chlorine |
Measuring principle |
Electrochemical electrode |
range |
0~20.00 mg/L(HClO) |
resolution |
0.01 |
precision |
±0.05 |
temperature compensation |
Automatic temperature compensation(PT1000) |
Shell material |
316L |
Installation method |
Installation of circulation pool,3/4NPT |
Dimensions |
D30mm,L185mm , 3 meters |
|
|
Test Item |
chloride ion |
Measuring principle |
Ion selection method |
range |
0~3500.0 mg/L,0~35000 mg/L |
resolution |
0.1,1 |
precision |
±5% |
detection limit |
0.9mg/L |
temperature compensation |
Automatic temperature compensation(PT1000) |
Shell material |
316L |
Installation method |
Immersive installation,3/4 NPT |
Dimensions |
D30mm,L185mm, 3 meters |
|
|
Test Item |
dissolved oxygen |
working principle |
fluorescence method |
measurement range |
(0-20)mg/L |
resolution |
0.01mg/L |
measurement accuracy |
0.3mg/L |
response time |
<45s |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
transparency |
working principle |
Transmissive measurement method |
measurement range |
(0-50)m |
resolution |
0.1cm |
measurement accuracy |
± 2% or 2cm |
linear error |
<5% |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
conductivity |
working principle |
Graphite electrode method |
measurement range |
(0-200,000)μS/cm |
resolution |
0.1 μ S/cm (depending on the measurement range) |
measurement accuracy |
<1% |
response time |
<15s |
Dimensions |
D30mm,L175mm , 3 meters |
|
|
Test Item |
nitrate |
working principle |
ion selective electrode |
measurement range |
(0-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
5% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
suspended solids |
working principle |
light scattering method |
measurement range |
(0-4,000)NTU |
resolution |
0.1NTU |
repetitiveness |
<5% |
Straightness |
<5% |
Dimensions |
D30mm,L175mm , 3 meters |
|
|
Test Item |
sludge concentration |
range |
0.5-4000mg/L |
precision |
±5% |
resolution |
0.1mg/L |
temperature range |
0~50 ℃ (non freezing) |
self-cleaning |
Integrated self-cleaning brush |
Dimensions |
D36,L198mm, 10-meter line |
|
|
Test Item |
chlorophyll |
working principle |
fluorescence method |
measurement range |
(0-500)μg/L |
resolution |
0.01μg/L |
repetitiveness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
blue-green algae |
working principle |
fluorescence method |
measurement range |
(0-2,000)kcells/mL |
resolution |
0.1kcells/mL |
repetitiveness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
fluoride ion |
working principle |
ion selective electrode |
measurement range |
(0.2-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
10% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
水中油 |
working principle |
fluorescence method |
measurement range |
(0-150)mg/L |
resolution |
0.01mg/L |
repetitiveness |
<5% |
communication interface |
RS485, Standard Modbus protocol |
Dimensions |
D30mm,L175mm, 3 meters |