GL-4100 water quality monitoring controller, a single parameter online water quality monitoring device, can be used for sensor display and calibration. The equipment can automatically recognize different types of digital and optical sensors from Greencaire, plug and play. At the same time, the device supports one RS485 output and one 4-20mA output, with optoelectronic isolation and strong anti-interference ability. The whole machine is IP65 waterproof and suitable for long-term online monitoring. The sensor adopts RS485 digital output and supports Modbus protocol.
Product Overview
GL-4100 water quality monitoring instrument controller,Single parameter water quality online monitoring instrument, can be used for sensor display and calibration, and the equipment can automaticallyIdentify different types of digital and optical sensors from Greencaire, plug and play. Simultaneously supporting equipmentHolding one RS485 output and one 4-20mA output, with optoelectronic isolation and strong anti-interference ability.Single parameter water quality online monitoring instrumentThe whole machineIP65 waterproof, suitable for long-term online monitoring use, sensor adopts RS485 digital output, supportsModbus protocol.
Application field
Widely used for monitoring enterprise wastewater, domestic wastewater, and surface water in industries, agriculture, scientific research, environmental protection, and other fields.
Features
01 |
|
Automatic recognition, plug and play, supports all digital and optical sensors of Greencaire. |
02 |
|
Automatically read the internal calibration records of the sensor, replacing the sensor does not require calibration, which saves more time. |
03 |
|
all the way4-20mA output, one RS485 digital output. |
04 |
|
Industrial grade standard, output isolation, strong anti-interference ability. |
05 |
|
IP65 protection level, suitable for various indoor and outdoor installation requirements. |
06 |
|
It has data storage, viewing, and export functions, and can set its own storage period. |
07 |
|
output signal RS485 Modbus RTU standard protocol. |
technical indicators
display interface |
5-inch backlit screen |
Shell material |
ABS |
ambient humidity |
≤80% |
transmitter output |
1 isolated 4-20mA output, 1 digital output, and 2 relay outputs. |
Overall dimensions |
144*144*115 mm |
Protection level |
IP65 rating |
power supply |
110~220V AC |
temperature compensation |
automatic |
Pressure compensation |
automatic |
measurement items |
pH、ORP、 Turbidity, chromaticity, residual chlorine, chloride ions, dissolved oxygen, transparency, conductivity, nitrate, temperature, suspended solids
filthMud concentration, chlorophyll, blue-green algaeCOD、 Ammonia nitrogen, fluoride ions, and oil in water can be paired with any sensor.
|
Test Item
Test Item |
COD |
working principle |
UV absorption method |
measurement range |
(0-500,500-1000)mg/L |
resolution |
0.1mg/L |
measurement accuracy |
±10% |
linear error |
<5% |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
ammonia nitrogen |
working principle |
ion selective electrode |
measurement range |
(0.2-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
10% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
PH |
working principle |
Glass electrode method |
measurement range |
(0-14)pH |
resolution |
0.01pH |
sensitivity |
(57-59)mV/pH |
measurement accuracy |
<0.1pH |
response time |
<15s |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
ORP |
measurement range |
-999~999mV |
measurement accuracy |
±20mV |
resolution |
1mV |
temperature range |
0~50 ℃ (non freezing) |
Specifications and Dimensions |
D28mm,L194mm, 10-meter line |
material |
POM+titanium alloy |
|
|
Test Item |
chroma |
working principle |
Optical absorption method |
Measure wavelength |
470nm,546nm |
measurement range |
(0-500)Hazen,(0-500)NTU |
measurement accuracy |
±2%FS |
resolution |
0.5Hazen |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
turbidity |
working principle |
light scattering method |
measurement range |
(0-4,000)NTU |
resolution |
0.1NTU |
repetitiveness |
<5% |
Straightness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
residual chlorine |
Measuring principle |
Electrochemical electrode |
range |
0~20.00 mg/L(HClO) |
resolution |
0.01 |
precision |
±0.05 |
temperature compensation |
Automatic temperature compensation(PT1000) |
Shell material |
316L |
Installation method |
Installation of circulation pool,3/4NPT |
Dimensions |
D30mm,L185mm , 3 meters |
|
|
Test Item |
chloride ion |
Measuring principle |
Ion selection method |
range |
0~3500.0 mg/L,0~35000 mg/L |
resolution |
0.1,1 |
precision |
±5% |
detection limit |
0.9mg/L |
temperature compensation |
Automatic temperature compensation(PT1000) |
Shell material |
316L |
Installation method |
Immersive installation,3/4 NPT |
Dimensions |
D30mm,L185mm, 3 meters |
|
|
Test Item |
dissolved oxygen |
working principle |
fluorescence method |
measurement range |
(0-20)mg/L |
resolution |
0.01mg/L |
measurement accuracy |
0.3mg/L |
response time |
<45s |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
transparency |
working principle |
Transmissive measurement method |
measurement range |
(0-50)m |
resolution |
0.1cm |
measurement accuracy |
± 2% or 2cm |
linear error |
<5% |
Dimensions |
D32mm,L175mm, 3 meters |
|
|
Test Item |
conductivity |
working principle |
Graphite electrode method |
measurement range |
(0-200,000)μS/cm |
resolution |
0.1 μ S/cm (depending on the measurement range) |
measurement accuracy |
<1% |
response time |
<15s |
Dimensions |
D30mm,L175mm , 3 meters |
|
|
Test Item |
nitrate |
working principle |
ion selective electrode |
measurement range |
(0-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
5% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
suspended solids |
working principle |
light scattering method |
measurement range |
(0-4,000)NTU |
resolution |
0.1NTU |
repetitiveness |
<5% |
Straightness |
<5% |
Dimensions |
D30mm,L175mm , 3 meters |
|
|
Test Item |
sludge concentration |
range |
0.5-4000mg/L |
precision |
±5% |
resolution |
0.1mg/L |
temperature range |
0~50 ℃ (non freezing) |
self-cleaning |
Integrated self-cleaning brush |
Dimensions |
D36,L198mm, 10-meter line |
|
|
Test Item |
chlorophyll |
working principle |
fluorescence method |
measurement range |
(0-500)μg/L |
resolution |
0.01μg/L |
repetitiveness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
blue-green algae |
working principle |
fluorescence method |
measurement range |
(0-2,000)kcells/mL |
resolution |
0.1kcells/mL |
repetitiveness |
<5% |
Dimensions |
D30mm,L175mm, 3 meters |
|
|
Test Item |
fluoride ion |
working principle |
ion selective electrode |
measurement range |
(0.2-1000)mg/L |
detection limit |
0.2mg/L |
measurement accuracy |
10% or ± 0.2mg/L |
Dimensions |
D42mm,L175mm, 3 meters |
|
|
Test Item |
水中油 |
working principle |
fluorescence method |
measurement range |
(0-150)mg/L |
resolution |
0.01mg/L |
repetitiveness |
<5% |
communication interface |
RS485, Standard Modbus protocol |
Dimensions |
D30mm,L175mm, 3 meters |