FS300PMF2 professional 500ml bottle top vacuum filtration device, equipped with PPSU filter cup and borosilicate glass collection bottle, focuses on culture medium sterilization and suspension detection, suitable for filtering large volume samples.
FS300PMF2 professional 500ml bottle top vacuum filtration device
Product description
FS300PMF2 is a 500ml bottle top vacuum filtration device, equipped with a PPSU filter cup and borosilicate glass collection bottle. It is mainly used for sterilization of culture media and detection of suspended solids, and is suitable for filtering large volume samples.
Large volume adaptation500ml filter cup+2000ml collection bottle, suitable for batch culture medium sterilization and suspension detection, reducing the frequency of bottle replacement.
Material corrosion-resistantThe PPSU filter cup is resistant to conventional acids, bases, and organic solvents, and the borosilicate glass collection bottle has good transparency, making it easy to observe the state of the filtrate.
Bottle top designDirectly connect to the blue cap reagent bottle, and the filtrate can be stored without transfer, reducing the risk of contamination.
Magnetic sealThe filter cup is magnetically attached to the base, allowing for quick membrane replacement and good sealing, with no side leakage.
safety protectionStandard anti backflow buffer cup+water/dust blocking filter element to protect the vacuum pump and sample.
Batch sterilization and filtration of culture medium in microbiology laboratory.
Quantitative detection of suspended solids (SS) in environmental monitoring.
Clarification and preservation of buffer solutions and culture media in pharmaceutical/chemical industries.
Sample pre-treatment filtration in the food/beverage industry.
FS300PMF2 professional 500ml bottle top vacuum filtration device

Technical parameters of products in the same series:
| model |
Filter cup capacity |
Collection bottle capacity |
Filter cup material |
Material of collection bottle |
Product Features |
application |
| R300MF |
300ml |
1000ml |
borosilicate glass |
borosilicate glass |
All use bottle top filters, which can be connected to ordinary laboratory cap reagent bottles. The filter element flows directly into the reagent bottle for storage |
Mobile phase reagent filtration |
| R300MF2 |
500ml |
2000ml |
borosilicate glass |
borosilicate glass |
All use bottle top filters, which can be connected to ordinary laboratory cap reagent bottles. The filter element flows directly into the reagent bottle for storage |
Buffer filtration |
| FS300PMF |
300ml |
1000ml |
PPSU polyphenylsulfone |
borosilicate glass |
All use bottle top filters, which can be connected to ordinary laboratory cap reagent bottles. The filter element flows directly into the reagent bottle for storage |
Culture medium sterilization |
| FS300PMF2 |
500ml |
2000ml |
PPSU polyphenylsulfone |
borosilicate glass |
All use bottle top filters, which can be connected to ordinary laboratory cap reagent bottles. The filter element flows directly into the reagent bottle for storage |
Suspended solids detection |
| R300-500 |
500ml |
500ml |
PES Polyether Sulfone |
borosilicate glass |
One handed membrane replacement, with bottom drain port and fixed seat |
Field sampling and filtering |
| R300SS |
300ml |
1000ml |
PES Polyether Sulfone |
borosilicate glass |
One handed membrane replacement, with bottom drain port and fixed seat |
Microbial limit of membrane sampling style |
| FS300PDC |
300ml |
1200ml |
PES Polyether Sulfone |
PES Polyether Sulfone |
Powered by a portable power bank, suitable for outdoor use |
Microbial Limit |
| FS300MLT |
100ml |
1000ml |
316L stainless steel |
borosilicate glass |
Funnel can be flame burned and sterilized |
Determination of oxides |
| FS300F-T3 |
300ml |
1200ml |
PSF polysulfone |
PSF polysulfone |
Polysulfone material, low adsorption, does not affect the detection results |
Cleanliness Inspection |
| FS300F-T5 |
500ml |
1200ml |
PSF polysulfone |
PSF polysulfone |
Polysulfone material, low adsorption, does not affect the detection results |
Micro and precious sample filtration |
| FS300CF |
300ml |
1000ml |
borosilicate glass |
borosilicate glass |
The filter membrane support sheet can be easily removed and cleaned |
Large capacity filtration |
| FS300CF2 |
500ml |
2000ml |
borosilicate glass |
borosilicate glass |
The filter membrane support sheet can be easily removed and cleaned |
Viscous high solid content filtration |
| FS300M |
15ml |
125ml |
borosilicate glass |
borosilicate glass |
Small size filter membrane reduces filtrate loss |
fiber filtration |
| FS400L |
1000ml |
5000ml |
borosilicate glass |
borosilicate glass |
Large capacity filtration bottle set, 90mm large-sized filter membrane, large-sized filter membrane increases effective filtration area, viscous high solids |
Alloy fiber measurement |
| FS410V |
1000ml |
2000ml |
borosilicate glass |
borosilicate glass |
Large size filter membrane increases effective filtration area, viscous high solids |
Vitamin phosphate filtration |
| ACC300FB |
100ml |
1000ml |
borosilicate glass |
borosilicate glass |
G4 sand core combination, specially designed for fiber detection |
Vitamin phosphate filtration |
| CH300PA |
300ml |
1000ml |
PPSU polyphenylsulfone |
PP Polypropylene |
The filter bottle is made of polysulfone and polypropylene materials, which can withstand strong acids that glass ceramics cannot tolerate |
- |
Product Features
Exclusive design for fiber testingPaired with G4 sand core, it adapts to the interception and filtration needs of fiber samples, and optimizes the structure specifically for fiber detection scenarios.
Blue cap reagent bottle compatibleCan be connected to laboratory blue cap reagent bottles, and the filtrate can be directly filtered into the reagent bottle for storage or injection, reducing transfer steps.
Multi funnel adaptationThrough silicone plugs, funnels of various materials and capacities can be connected to enhance scene flexibility.
Material durabilityThe filter cup and collection bottle are both made of borosilicate glass, which is resistant to conventional acids, bases, and organic solvents, and is suitable for common reagents in fiber detection.
Fiber content testing in the textile/paper industry
Fiber based pollutant filtration in environmental monitoring
Pre treatment of fiber samples in scientific research experiments
GL45 blue cap reagent bottle filter connection cap

1. Can connect laboratory blue cap reagent bottlesCan be connected to laboratory blue label cap reagent bottles to filter the filtrate into the bottles for storage or injection
2. Can be connected and used with various funnelsThrough silicone plugs, it can be connected to funnels of various materials and capacities for use