E-mail
sales@m-excel.cn
-
Phone
13361898597
-
Address
Building 1, No. 65, Lane 1398, Xinzhu Road, Minhang District, Shanghai
Shanghai Maiyue Environmental Technology Co., Ltd
sales@m-excel.cn
13361898597
Building 1, No. 65, Lane 1398, Xinzhu Road, Minhang District, Shanghai
M-2010-FTAFTA technology for RTO combustible gas LEL concentration analyzerBy using flame temperature detection (FTA) technology, the temperature change generated by the combustion of combustible gases can be quickly and accurately measured. It can simultaneously detect organic VOCs gases, inorganic explosive gases such as CO, H2, NH3, etc., and respond to all combustible gases. The measurement range can cover 0-100% LEL, providing safe and reliable real-time monitoring of explosion risks for various industries. It can be widely used for monitoring LEL explosion limits in petroleum and petrochemical industries, tank farms, and process pipelines. The product adopts a body explosion-proof design and can be used in Zone 1 and Zone 2 explosion-proof situations.

The sample is drawn into the flame chamber of the analyzer, and the combustible gases and vapors in the sample burn in the induction flame. The thermocouple located near the induction flame converts the temperature rise into an electrical signal, and the temperature rise is proportional to the 0-100% lower limit of combustion (LEL) concentration of the combustible gas. In the flame chamber, a small "induction flame" is ejected from the end of the combustion tube. The sample is continuously sucked into the flame chamber by the suction force generated by the jet pump through the sampling tube, and is introduced into the flame chamber at a constant pressure. The combustible gas in the sample burns in the induction flame and produces a temperature rise proportional to the lower limit of combustion, which is measured by a thermocouple located above the flame.
Product advantages
M-2010-FTAFTA technology for RTO combustible gas LEL concentration analyzerIt has significant advantages in industries such as petroleum, chemical, and pharmaceutical, and its products have the following technical characteristics:
Fast response time: T90 ≤ 2S
Jet pump sampling, suitable for low-pressure sampling conditions
The system is heated throughout the entire process to avoid condensation and adsorption of organic matter in the sample gas
Can analyze almost all combustible gases
Multiple component gases can be measured using a single gas calibration method
Built in EPC flow control for stability
Stable and reliable measurement
Product application scenarios
LEL monitoring at the inlet of exhaust gas treatment equipment (RTO/RCO/incinerator, etc.)
Monitoring and warning of the lower explosive limit of solvent saturated air
Monitoring and Warning of Explosion Lower Limit in Oil Storage Tank Area
Monitoring and warning of lower limit of process pipeline explosion

technical indicators
Brand Mexcel Maiyue Environment
Model numberM-2010-FTA
Measurement of combustible organic and inorganic gases in components
Range LEL: (0)~100)%LEL
The analyzer is heated to 120 ℃, and other temperatures can be customized
Injection pressure -20~20kPa (gauge pressure)
Sampling flow rate of 2.5L/min
Repeatability ≤ 1%
Response time T90 ≤ 2S
Zero point and range drift ≤± 2% F.S./24h
Linear error ≤± 1% F.S
Communication protocol RS485, Modbus communication protocol
Size 650mm × 315mm × 800mm (L × W × H)
Weight 65kg, environmental humidity (0~95)%RH
Environmental temperature (-20 ° C)~50)℃
Working power supply 220 VAC, 50Hz
Power start 500W, run 150W
Explosion proof grade Ex db Px IIC T4 Gb