Used for disinfection in biological preparation workshops. It has two evaporation modules, which respectively produce formaldehyde gas for disinfection and ammonia steam for neutralization. Accurately adjust the amount of occurrence and work timing.
1 Overview
This device is used to generate formaldehyde vapor for fumigation of spaces such as places and ventilation ducts, and can also produce ammonia vapor for use
And achieve the purpose of disinfection and sterilization.
2 Working principle
This equipment consists of several parts, including storage tank, metering pump, flash evaporator, fan, distributor, formaldehyde concentration sensor, and system controller. During disinfection, formaldehyde is accurately metered by a metering pump and enters the formaldehyde flash evaporator (1 #), where it evaporates and diffuses into the space through a fan and distributor. When neutralizing, switch to the ammonia flash evaporator (2 #), which also diffuses into the space through the fan and distributor for residual formaldehyde neutralization. All operations are set and regulated through the system controller.

Equipment Process Flow Diagram
3 parameter indicators

4 Equipment interfaces

1. Tank box 2. Main control switch 3. Heating switch 4. Touch screen 5. Air outlet interface 6. Printing port 7. Power socket 8. Air inlet