Hash MS5056 turbidity residual chlorine pH analyzer
-Application industry:
MS5056/MS5056 Lite Industrial Panel Type Multi Parameter Online Analyzer: Suitable for Monitoring Before Industrial RO Membrane
MS5056 Pro Industrial Multi Parameter Online Analyzer: Analysis for Industrial Cooling Circulating Water and Complex Water Quality Environments

Hash MS5056 turbidity residual chlorine pH analyzer
-Measurement principle:
Residual chlorine/chlorine dioxide probe: using the principle of constant voltage measurement, with a three electrode structure (working electrode, counter electrode, and reference electrode), and integrating pH glass electrode and PT100 temperature electrode, it solves the pH and temperature compensation of residual chlorine measurement under complex working conditions, ensuring high accuracy and stability of measurement results;
Turbidity probe: The light source adopts warm white LED (color temperature 3200K), which measures the turbidity of water based on the 90 ° scattering principle and meets the EPA-180.1 standard. It can effectively measure the turbidity changes under different water quality conditions;
ORP probe: a composite electrode structure based on platinum electrode and reference electrode, used for accurate measurement of oxidation-reduction ability in water, widely used in water quality monitoring and chemical treatment processes;
Conductivity: The graphite four electrode measurement principle, with built-in PT100 temperature compensation, can achieve accurate measurement of conductivity over a wide range (0-100mS/cm), suitable for conductivity monitoring of various water quality types.
-Instrument features:
The MS5056 industrial panel type multi parameter online analyzer uses a three parameter composite residual chlorine/chlorine dioxide electrode to achieve a probe output of residual chlorine (chlorine dioxide), pH, and temperature values. This industrial multi parameter online analyzer has built-in temperature and pH dual parameter compensation functions on the electrodes, using algorithms to reduce the impact of temperature and flow rate on residual chlorine and pH values. The electrode implementation system has no membrane or filling solution, resulting in low maintenance.
The MS5056 Pro series industrial multi parameter online analyzer comes with a self-cleaning flow cell as standard, which can achieve active cleaning of the probe and is suitable for more harsh and complex water samples. It can effectively reduce the daily maintenance of the probe and is simpler and more convenient to use.
The MS5056 industrial panel type multi parameter online analyzer has a chlorine electrode made of gold material, which is more stable.
The MS5056 industrial multi parameter online analyzer turbidity sensor uses an LED detection light source that complies with the USEPA 180.1 standard color temperature, which is an approved method under USEPA 40 CFR 141.74 (a) (1). The highest resolution can reach 0.001NTU, and it runs stably for a long time.
The MS5056 Pro series industrial multi parameter online analyzer adopts a turbidity probe that is more suitable for industrial sites, a pollution resistant embedded optical glass detection channel, and is more suitable for applications such as cooling and circulating water.
MS5056 industrial multi parameter online analyzer is designed for different application scenarios, and customers can choose residual chlorine or chlorine dioxide measurement according to their needs. And conductivity and ORP probes can be optionally selected to meet various needs.
For high chlorine water quality environments/seawater environments, customers can choose corrosion-resistant materials (CPVC material) for residual chlorine or chlorine dioxide electrodes, as well as titanium alloy turbidity probes.
MS5056 industrial panel type multi parameter online analyzer has a small installation area and is easy to install; Pre calibration at the factory, simple on-site operation and maintenance, and low professional requirements for operators.
| Standard chlorine probe parameters: | |||
|---|---|---|---|
| measurement parameters | Residual chlorine/chlorine dioxide | PH | temperature |
| measurement range | 0-5 mg/L Cl2Or CLO2plan | 2-12 | -5℃ ~65℃ |
| Detection limit | 0.01 mg/L | 0.01 pH | -5℃ |
| display resolution | 0.01 mg/L | 0.01 pH | 0.01℃ |
| accuracy | ± 0.01 ppm or ± 2% reading, whichever is greater | ± 0.02pH@25 ℃ | ±1% |
| repetitiveness | 2% | 0.01 pH | 0.5℃ |
| minimum resolution | 0.01 mg/L | 0.01 pH | 0.1℃ |
| response time | T90 ≤ 120S | T90 ≤ 30S | T90≤ 30S |
| Measurement interval | continuous measurement | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | RS-485 output | |
| Probe material | SS304 shell, electrode front end made of gold+platinum+glass+CPVC+SS304 | ||
| Standard turbidity probe parameters: | ||
|---|---|---|
| measurement parameters | Turbidity (applicable to MS5056/MS5056 Lite series) | Turbidity (applicable to MS5056 Pro series) |
| measurement range | 0-10/10-40NTU | 0-100NTU |
| Detection limit | 0.001 NTU | 0.5 NTU |
| display resolution | 0.001 NTU | 0.1 NTU |
| accuracy | ± 0.01NTU or ± 2% reading, whichever is greater | ± 0.5NTU or ± 2% FS, whichever is greater |
| repetitiveness | 1% | 2% |
| minimum resolution | 0.001NTU | 0.1NTU |
| response time | T90 ≤ 30S | T90 ≤ 30S |
| Measurement interval | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | 4-20mA and RS-485 dual output |
| Probe material | SS304 shell+optical glass | CPVC shell+optical glass |
| Optional probe parameters: | ||
|---|---|---|
| measurement parameters | ORP | conductivity |
| measurement range | ±1500mV | 0-100,000μS/cm |
| Detection limit | -1500 mV | 10 μS/cm |
| display resolution | 1 mV | 1 μS/cm |
| accuracy | ± 20mV or 2% FS, whichever is greater | ± 10 μ S/cm or ± 1% reading, whichever is greater |
| repetitiveness | 2% | 1% |
| minimum resolution | 1 mV | 1 μS/cm |
| response time | T90 ≤ 25S | T90 ≤ 20S |
| Measurement interval | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | 4-20mA and RS-485 dual output |
| Probe material | Shell: CPVC; Electrode: Platinum | Shell: CPVC; Electrode: Graphite |
| System parameters: | |
|---|---|
| measurement parameters | |
| display screen | 4.3 "TFT 480x272 touch screen |
| power supply | 100-240VAC, 50/60 Hz |
| power | About 30W |
| Analog output | Residual chlorine pH、 Turbidity and temperature each have a 4-20mA output |
| communication interface | RS485、Modbus RTU、 Relay (optional: 2-channel DC relay, rated voltage 24 VDC, total rated current up to 1.5A; 3-channel AC relay, rated voltage 220 VDC, total rated current up to 5A) |
| Data export | USB drive |
| System upgrade | USB drive |
| Operating Temperature | 5-45℃ |
| Storage temperature | -20~55 ℃ (excluding probe) |
| relative humidity | 5% -95% (non condensing) |
| altitude | ≤ 2000 meters |
| Water sample requirements | MS5056/MS5056 Lite Temperature: 5~45 ℃; Pressure: 0.05~0.25 MPa. If it exceeds 0.25 MPa, a pressure reducing valve needs to be added; Flow rate of circulation pool: greater than 470mL/min MS5056 Pro Temperature: 5~45 ℃; Pressure: 0.05~0.2 MPa; Flow rate of circulation pool: greater than 200mL/min |
| Box material | All plastic, corrosion-resistant |
| size | 750mm X 500mm X 230.5mm |
| weight | Approximately 25 kilograms (including packaging, maximum weight) |
| Ordering Guide | |
|---|---|
| Order Information | |
| MS5056.01P. P | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, suitable for complex water quality environments |
| MS5056.01PE. P | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity, suitable for complex water quality environments |
| MS5056.01PO. P | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, ORP, Suitable for complex water quality environments |
| MS5056.01POE. P | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity, ORP, Suitable for complex water quality environments |
| MS5056.01P | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity |
| MS5056.01PE | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity |
| MS5056.01PO | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, ORP |
| MS5056.01POE | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity, ORP |
| MS5056.01P. L | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity (no relay alarm) |
| MS5056.01PE. L | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity (without relay alarm) |
| MS5056.01PO. L | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, ORP (no relay alarm) |
| MS5056.01POE. L | Industrial multi parameter online analyzer, residual chlorine, PH, Temperature, turbidity, conductivity, ORP (no relay alarm) |
| MS5056.02P. P | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, suitable for complex water quality environments |
| MS5056.02PE. P | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity, suitable for complex water quality environments |
| MS5056.02PO. P | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, ORP, Suitable for complex water quality environments |
| MS5056.02POE. P | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity, ORP, Suitable for complex water quality environments |
| MS5056.02P | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity |
| MS5056.02PE | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity |
| MS5056.02PO | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, ORP |
| MS5056.02POE | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity, ORP |
| MS5056.02P. L | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity (no relay alarm) |
| MS5056.02PE. L | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity (without relay alarm) |
| MS5056.02PO. L | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, ORP (no relay alarm) |
| MS5056.02POE. L | Industrial multi parameter online analyzer, chlorine dioxide, PH, Temperature, turbidity, conductivity, ORP (no relay alarm) |
| MS5056 Accessories and Consumables Ordering Information | |
| R43PRO01 | Online residual chlorine composite probe |
| R43PRO02 | Online chlorine dioxide composite probe |
| R43PRO03 | Online ultra-low turbidity probe, suitable for MS5056/MS5056 Lite series |
| R43PRO04 | Online turbidity probe, suitable for MS5056 Pro series |
| R43SLEEC | Online conductivity probe component |
| R43SLEORP | Online ORP probe assembly |
| R43SLECL | Front end electrode tip |
| R43SLE12 | Removable brush assembly, suitable for MS5056 Pro series |
| R43SLE01 | Turbidity calibration tank |
| R43SLE02 | Turbidity calibration dry standard set |
| S11M004 | PH 7.000 standard solution |
| S11M007 | PH 10.012 standard solution |
| LZY899 | StablCal packaging standard, 20NTU |
| LZY898 | StablCal Calibration Kit (10, 20, 600NTU) |
| 25M2A1002-115CN | GLI, International standard solution for oxidation-reduction, 600 mV |
| LZW9700.99 | Conductivity standard solution, 147 uS/cm |
| LZW9710.99 | Conductivity standard solution, 1413 uS/cm |
| MS5056 expandable selection electrode information | |
| R43SLEECH | Online conductivity probe assembly, measurement range: 0-300000 uS/cm |
| R43PRO05 | Online corrosion-resistant residual chlorine composite probe, measurement range: 0-5 mg/L, CPVC shell+optical glass |
| R43PRO06 | Online corrosion-resistant chlorine dioxide composite probe, measurement range: 0-5 mg/L, CPVC shell+optical glass |
| R43PRO07 | Online corrosion-resistant ultra-low turbidity probe, measuring range: 0-40 NTU, titanium alloy shell, suitable for MS5056 Pro series |