Hash MS5100 turbidity/residual chlorine/PH multi parameter water quality analyzer
-Product features:
The MS5100 multi parameter online analyzer adopts an integrated design with a small footprint. Continuous monitoring includes residual chlorine, chlorine dioxide, turbidity pH、ORP、 Conductivity and temperature are 7 water quality parameters.
The MS5100 multi parameter online analyzer adopts a series flow path to meet customers' water saving needs
The MS5100 multi parameter analyzer is equipped with a residual chlorine automatic cleaning mechanism, which has a longer maintenance cycle
MS5100 multi parameter water quality online analyzer with electrochemical flow cell modular structure easy to disassemble and clean
The MS5100 multi parameter online analyzer adopts flange sealing for pH, conductivity, and ORP electrodes, which is easy to disassemble and assemble
MS5100 multi parameter online analyzer supports dynamic water-saving mode, effectively reducing water resource consumption
Hash MS5100 turbidity/residual chlorine/PH multi parameter water quality analyzer in stock
| Ordering Guide | |
|---|---|
| model | configuration |
| MS5100.10 | MS5100 Standard Edition, (including residual chlorine&pH PCBA+turbidity+temperature, excluding residual chlorine and pH electrode) |
| MS5100.11 | MS5100 Standard Edition+Electrochemical Module (Electrochemical PCBA+Flow Cell+Accessories) |
| MS5100.12 | MS5100 Standard Edition+IO Module (IO PCBA+Accessories) |
| MS5100.13 | MS5100 Standard Edition+Electrochemical Module+IO Module (Electrochemical PCBA+Flow Cell+IO PCBA+Accessories) |
| (1) The electrodes need to be ordered separately. The electrodes are shipped separately and not with the instrument. (2) The ORP module is optional and only applicable to instruments installed on models MS5100.11 and MS5100.13. (3) The instruments all include Modbus communication, and 4-20 mA output is an optional module. | |
| technical indicators | |
|---|---|
| measurement method | Residual chlorine/chlorine dioxide: Three electrode constant potential method; Turbidity: 90 degree scattering method, EPA180.1; PH: glass electrode method; ORP: Platinum electrode direct measurement method; Conductivity: Two pole platinum electrode method; Temperature: Thermistor NTC 30K; |
| measurement range | Residual chlorine: 0~10 mg/L; Chlorine dioxide: 0-5 mg/L; Turbidity: 0~100 NTU; pH:0.00 ~ 14.00; ORP:-1200 mV ~ +1200 mV; Conductivity: 20.0 μ S/cm~2000 μ S/cm; Temperature: 0 ℃~50 ℃ |
| detection limit | Residual chlorine/chlorine dioxide: 0.01 mg/L; Turbidity: 0.0032 NTU; Conductivity: 6.0 μ S/cm; |
| accuracy | Residual chlorine: ± 1% or ± 0.01 mg/L (whichever is greater); Chlorine dioxide: ± 1.5% or ± 0.01 mg/L (whichever is greater); Turbidity: ± 2% or ± 0.01 NTU (whichever is higher); (Based on Formazine primary standard solution at 25 ℃) pH:±0.02(2~12 pH); ORP:±20 mV; Conductivity: ± 0.8% F.S; Temperature: ± 0.4 ℃; |
| repetitiveness | Residual chlorine: 1% or 0.01 mg/L (whichever is greater); Chlorine dioxide: 1.5% or 0.01mg/L (whichever is greater); Turbidity: 1% or 0.006 NTU (whichever is higher); (Based on Formazine primary standard solution at 25 ℃) pH:0.01; ORP:10 mV; Conductivity: 0.4% F.S; Temperature: 0.2 ℃; |
| display resolution | Residual chlorine/chlorine dioxide: 0.001 or 0.01 mg/L optional Turbidity: 0.001, 0.01, or 0.1 NTU optional; pH:0.001 、 0.01 or 0.1 is optional; ORP: 0.01 or 0.1 mV optional; Conductivity: 0.01, 0.1 μ S/cm/mS/cm optional; Total dissolved solids (TDS): 0.01, 0.1 μ g/L/mg/L optional; Temperature: 0.01 ℃; |
| response time | Electrochemical electrode (pH/ORP/conductivity electrode) T90 response time<3 minutes; System T90 response time (calculated from the moment the water sample enters the instrument)<10 minutes |
| data log | About 104000 records, 12 months (assuming per minute/record) |
| Operating Temperature | 5~40 ℃ (41~104 ℉), relative humidity ≤ 95%, no condensation |
| Storage temperature | -20~60 ℃ (-4~140 ℉), relative humidity ≤ 95%, no condensation |
| self-diagnosis | Equipped with Prognosys self diagnostic system |
| Measurement Mode | Continuous mode, water-saving mode |
| altitude | Up to 2000 meters (6562 feet) |
| Power requirements | 100 - 240 VAC, 50/60 Hz |
| rated power | 30W |
| analog output | 6-way 4-20 mA analog output |
| digital output | RS485 Modbus |
| display screen | 7-inch color resistive touch screen |
| shell protection | IP65 (with the chassis door closed), for indoor use only |
| size | 452 x 681 x 335 mm (17.8×26.8×13.2 in) |
| Shipping weight | 25 kg (51.1 lb), No water supply |
| Installation method | wall-mounted |