Hash TC2300 online particle counter for water quality in the United States

NegotiableUpdate on 04/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Hash TC2300 online particle counter in the United States can measure the size and quantity of particles in water in real time, accurately reflecting the water quality situation. This particle counter ensures the accuracy and reliability of data through efficient detection technology, and can effectively support various needs of water treatment and monitoring.
Product Details

Hash TC2300 online particle counter for water quality in the United States

美国哈希TC2300水质在线颗粒计数器

-Working principle:

The TC2300 online particle counter can measure the size and quantity of particles in water in real time, accurately reflecting the water quality situation. This particle counter ensures the accuracy and reliability of data through efficient detection technology, and can effectively support various needs of water treatment and monitoring.


With the continuous improvement of people's living standards and the increasing emphasis on health, the quality requirements for drinking water are becoming increasingly strict. As an important link in ensuring the safety of drinking water for urban residents, water supply plants have continuously developed and improved their production processes and water quality monitoring technologies.In the current water supply industry, improving water quality and ensuring safe and stable water supply have become the top priority.


Water plants usually monitor turbidity during the process, which reflects the degree of light scattering by suspended particles in waterIt is difficult to distinguish what kind of particles are causing it, andParticle counterCan directly measure the number of particles in water andSize distribution. Research in the United States has shown that when the number of particles with a diameter greater than 2 μ m in water exceeds 100 particles/mL, there are "twoThe probability of insects is relatively high.Many water plants in the United States and Canada control the number of particles with a particle size greater than 2 μ m in the effluent of the filter tank50/mL, in addition, according to domestic and foreign research,Particle changes occur several hours before significant changes in turbidity, and their reactions are more sensitive,It can provide sufficient disposal time for water plant operators, therefore,The particle counter can provide more accurate and detailed water quality information for water supply plants.



-Application industry:

Widely used in municipal water plants to assist in water quality monitoring and management.


-Target customer group:

Mainly targeting municipal water plant design institutes, water plants, municipal pipeline networks and other related institutions.


-Instrument features:

TC2300 online particle counter provides the particle size and quantity of particles in water samples, helping users to comprehensively understand water quality.

The particle counter responds quickly to dynamic changes in water samples, ensuring real-time monitoring

The TC2300 online particle counter is equipped with an injection flow control system to ensure stable measurement

The online particle counter can simultaneously monitor 8 channels with optional particle sizes, improving detection flexibility

The TC2300 online particle counter is equipped with a color touch screen for easy operation

technical indicators


screen size

5.7-inch color touch screen
Measuring principle Photoresist method
particle size range 2~400 μm
Sample flow rate 60mL/min
sensitivity 2.0 µm
Counting compensation method traffic compensation
Relative error in particle counting ± 10% or ≤ 5CNT/mL, whichever is higher
Particle count repeatability ≤ 3% or ≤ 10 CNT/mL, whichever is greater
zero drift ≤5 CNT/mL
data storage About 60000 measurement records
contact method Modbus RS485 ,4-20mA
Operating Temperature 0-50 degrees Celsius (non condensing)
relative humidity 18~90% RH (non condensing)
power supply 100-230VAC; 50-60Hz
size 452 * 414 * 358 millimeters
Installation method wall-mounted




Ordering Guide
Item Number description
TC2300.10 TC2300 online particle counter

Accessory Information
Item Number description
T02SEL001 Shepherd fighting tube component
T02SEL002 Laser sensor inlet pipe component
T02SEL003 drain pipe
T02SEL004 inlet pipe
T02SEL005 overflow pipe
T02SEL006 filter screen
T02SEL007 Cleaning Kit
T02SEL008 desiccant

Hash TC2300 online particle counter for water quality in the United States