Welcome Customer !

Membership

Help

Shandong Geert Environmental Technology Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Shandong Geert Environmental Technology Co., Ltd

  • E-mail

    sdgerte@126.com

  • Phone

    15376881676

  • Address

    Room 458, 3rd Floor, Building 8, No. 106 Xiangyang Road, Chengyang District, Qingdao City, Shandong Province

Contact Now

High precision turbidity dust monitoring instrument

NegotiableUpdate on 02/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The high-precision turbidity dust monitoring instrument is an integrated structure, and the measuring electrodes are made of imported protective materials, which improves the ability to withstand high temperatures, corrosion, and adhesion, reduces cleaning and maintenance, extends the service life, and improves product quality.
Product Details

High precision turbidity dust monitoring instrumentAdopting improved AC coupling technology, it has high sensitivity and good linearity for dust detection. Dust contamination of the probe does not affect the measurement sensitivity and is maintenance free and cleaning free. Standard two-wire 4-20mA current output (other output methods can be customized), strong anti-interference ability, easy long-distance signal transmission, no special requirements for signal transmission wires, linear relationship between output current and dust concentration, convenient for subsequent PLC data processing. The integrated transmitter output 4-20mA current in the junction box is electrically isolated from the dust sensing probe to achieve safe signal transmission. The product has an integrated structure, and the measuring electrodes are made of imported protective materials, which improves the ability to withstand high temperatures, corrosion, and adhesion, reduces cleaning and maintenance, extends the service life, and improves product quality. The main body of the sensor is designed with airtight connectors to prevent the leakage of the measured gas and the outward impact of the measuring electrode due to pressure, ensuring the safety of the transmitter and personnel.

高精度浊度粉尘监测仪High precision turbidity dust monitoring instrumentIt is one of the important equipment to ensure the safe and environmentally friendly operation of dust removal equipment systems. It can integrate operation, display, alarm, and system operation status traceability, achieve real-time online monitoring of dust concentration in the clean air chamber of the dust collector, prevent dust concentration exceeding the standard due to factors such as bag dropping and leakage during operation, eliminate hidden dangers, improve equipment safety guarantee, timely, continuously, and accurately reflect equipment operation status, avoid safety accidents, and reduce equipment accident rate.

technical specifications

Operating environment temperature

-20 ℃~60 ℃ (electronic components)

Operating environment humidity

Non condensing 90%

Operating environment vibration

Maximum continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2)

Operating environment electromagnetic field

At 50 HzZui high value=60A/m (equivalent to a magnetic field of 50AT inside a 1m x 1m square electromagnetic coil)

Protection of operating environment

Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe

Pipeline gas pressure

-0.1-1MPa (maximum up to 8MPa)

Pipeline gas flow rate

1m/s~30m/s

Pipeline gas temperature

Real time temperature: 200 ℃, instantaneous temperature: 260 ℃ (260 ℃ -800 ℃ can be customized)

outer diameter of pipe

0.1 meters to 4 meters

Probe structure

The standard probe is 16mm in diameter, with a length ranging from 100mm to 1000mm. The probe material is rare earth amorphous alloy,

Dust particle size range

The nominal range is 0.1 μ M to 200 μ M, and it can still receive signals outside the nominal range, but the signal characteristics are slightly different.

Powder material

Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter

zero drift

(Time) Less than 1% of the range per year.

zero drift

Within the specified temperature range, below 1% of the measuring range.

Full-scale drift

(Time) Less than 1% of range per year

Full-scale drift

Within the specified temperature range, below 1% of the measuring range.

Line stability

All components of the system are made of high stability electronic assemblies.

Noise resistance

All 50 or 60 Hz audio and harmonics are filtered out before the signal is received

measurement range

0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (customized for special ranges)

Transmitter output mode

Standard 4-20mA (two-wire system) (customizable switch quantity, RS485 communication, Modbus RTU protocol, HART protocol, etc.)

Transmitter power supply

24V (available within the range of 15V to 32V)

measurement accuracy

±1%

Probe length selection

Please select the probe length according to the formula, i.e. D/3 ≤ L ≤ 2D/3

(Among them: D - Inner diameter of pipeline, L - Probe length)

Explosion-proof marking

Exia IIC T6 Ga/ExoD 21 T80 ℃ Certificate Number: CNV21.0092X

Ex db IIC T6 Gb, Ex tb IIC T80 ℃ Db Certificate Number: CNV24.1117X