With the overall improvement of national living standards and people's increasing awareness of health, their requirements for the working environment are also becoming higher. Firstly, they need satisfactory salary and benefits, and secondly, they hope to have a healthy and comfortable working environment. Moreover, protecting the environment and maintaining health are also the focal points of global concentration today.
Preventive maintenance and upkeep
1. Pre season maintenance. Before the start of the usage season, check for any obstacles around the unit and the air inlet.
2. Use and maintenance of the unit. Pay attention to the cleanliness of the chassis, and press the "Clean" button on the control board every day to change the water for cleaning to prevent bacteria and odors from occurring.
3. Periodic maintenance of the unit. The unit has been running for 1-2 months. If the wet curtains, filter screens are clogged, or the floor is too dirty, they should be cleaned in a timely manner to avoid machine failure or affecting its operational efficiency.
4. End of season maintenance. To prevent freezing damage to the body and mosquito breeding, when not in use for a long time, turn off the tap water, then press the cleaning button to drain the water, and cut off the power.
5. Clean the interior of the unit. If the machine runs for a long time, in order to ensure the cooling effect, the inside of the machine must be cleaned once every 1 or 2 months. Please refer to the instruction manual for detailed disassembly and cleaning methods.
Warning
1. The above matters should be strictly followed by the user. If accidents occur due to improper use of the machine, the manufacturer is not obligated to assume responsibility. Basic knowledge
What is the core of environmentally friendly air conditioning? Have you all heard about it? The main core of environmentally friendly air conditioning is the evaporative filter, which is mainly composed of multiple layers of corrugated fibers stacked together. The actual evaporative area is equivalent to 100 times the area occupied by the evaporative filter Rapid evaporation and heat exchange between air and water effectively reduce the temperature of the air, which is then sent into the computer room through a ventilation system to achieve ventilation and cooling
The air cooler uses ordinary tap water, which achieves partial recovery of water resources through some technologies and ensures that the computer room cannot be filled with water The cooling range of air coolers can usually reach 3 to 15 degrees Celsius, and the specific cooling range depends mainly on the humidity of the environment. The drier the place, the better the evaporation effect, and the greater the cooling amplitude.
2. Please do not modify, repair, or relocate the machine by yourself. The above tasks require professional personnel to complete, otherwise accidents may occur.
| model | KT25B-20 | KT40B-35 | KT45B-45 | KT60B-60 |
| Maximum air volume [m]3/h] | 25000 | 40000 | 45000 | 60000 |
| Airflow [m]3/h] | 20000 | 35000 | 45000 | 60000 |
| Input power [kW] | 7.0 | 10.3 | 12.8 | 15.9 |
| Voltage/Frequency [V/Hz] | 380/50 | 380/50 | 380/50 | 380/50 |
| Rated current of motor [A] | 11.3 | 12.1 | 22.1 | 31.4 |
| Water storage capacity [L] | 64 | 80 | 100 | 100 |
| Evaporation rate [L/H] | 117 | 220 | 260 | 380 |
| Energy efficiency ratio [kW/kW] | 13 | 14 | 14 | 16 |
| Net weight [kg] | 300 | 450 | 585 | 650 |
| Dimensions [LxWxH (mm)] | 1470x1490x1400 | 1770x1770x1440 | 2045x1970x1700 |
2055x1970x1700 |