Water air conditioning, also known as water-cooled air conditioning, uses groundwater as a circulation system. The water temperature around 15 meters underground is usually around 18 degrees Celsius. In summer, water is pumped up by a water pump and cooled by an indoor fan coil unit. The return water flows back underground through pipes
Water air conditioning, also known as water-cooled air conditioning, uses groundwater as a circulation system. The water temperature around 15 meters underground is usually around 18 degrees Celsius. In summer, water is pumped up by a water pump and cooled by indoor fan coils. The return water flows back underground through pipelines. This cycle in winter can achieve the purpose of heating.
Bottom air outlet of water-cooled air conditioner
Installation technical requirements for top and bottom air outlets
1. Use 40, 40, and 4 angle iron frames to connect with walls or window panels using bolts.
2. All gaps are sealed with glass glue and cement sand.
The cross-sectional area of the air supply duct for environmentally friendly air conditioning should not be less than 0.45 square meters, and the top air outlet for water-cooled air conditioning.
4. The welding and installation of the triangular bracket must be firm.
The installation bracket must be level with the host.
All exterior wall air ducts must be properly waterproofed.
7. The bottom of the host and the contact part with the bracket must be cushioned with shock-absorbing pads.
The installation on the zinc iron tile shed should have sufficient strength to withstand the weight of the water-cooled air conditioning unit.
9. The size of the roof or roof opening should not exceed 20mm of the size of the air duct, otherwise waterproofing treatment cannot be done properly.
Adequate air intake and maintenance space should be left at different installation locations.
The cross-sectional area of the air duct entering the wall or window shall be determined according to the usage location, but shall not be less than 0.45 square meters.
The remote control receiver box is connected to the communication line and introduced into the room through the air outlet duct. It is installed in a position that is easy to receive remote control signals, and a 22mm hole must be opened on the air outlet duct and fixed in an appropriate position indoors.
Koreilai water-cooled air conditioner
Keeping the indoor temperature constant can greatly reduce the indoor air quality, leading to air pollution, unpleasant odor, headaches, nausea, and other so-called "air conditioning diseases". For some workshops that produce harmful gases, without necessary ventilation equipment, it can cause poisoning. However, high-efficiency and energy-saving air conditioning can solve this problem. In operation, it is necessary to open doors and windows, continuously supply cold air, eliminate hot air, and always maintain a fresh and natural cold air environment.
Effect description: Koreilai water-cooled air conditioning provides one-on-one cooling for each employee on the assembly line, with adjustable air volume for each position. 20 units of 18000 air volume Koreilai environmental protection air conditioning models deliver fresh cold air into the room at a maximum total air volume of 360000 air volume per hour, enabling rapid air circulation in the workshop to achieve overall cooling, ventilation, and air exchange effects. Koreilai Environmental Protection Air Conditioner YC25B is truly the strongest king in the field of cooling and ventilation!
National Service Hotline:
Contact: Mr. Zhao
mobile phone
Website: www.yuechangcn.com
Email: yuechangcn@163.com
Factory Address: Block B, No. 11 East Sifang Street, Xiaoxiang Community, Wanjiang, Dongguan City