Welcome Customer !

Membership

Help

Liaoning Bisun Petrochemical Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Liaoning Bisun Petrochemical Technology Co., Ltd

  • E-mail

    18242399111@139.com

  • Phone

    13842345416

  • Address

    Changchun Street East Section, Shuncheng District, Fushun City, Liaoning Province

Contact Now

Liaoning closed sampler in stock

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Before sampling, prepare $n ■ for the Liaoning closed sampler. Select the corresponding volume of sampling steel cylinder (seamless steel cylinder) according to the required sample size for the experiment. The steel cylinder should be kept clean and dry, and its tare weight should be weighed. Empty and flush the chambers and inner surfaces of all components inside the sealed sampler. Follow the sampling steps specified on the enclosed sampler panel according to the instructions on the label. Adjust the sampling volume: Discharge liquid phase samples exceeding 80% of the sampling cylinder volume. Using weighing method or reserved volume tube
Product Details

Liaoning closed sampler in stockIt is a sampling method that complies with laboratory analysis and safety regulations, as it first ensures that volatile substances are not directly emitted into the atmosphere; Secondly, using a closed sampler for sampling eliminates the possibility of sampling personnel inhaling volatile toxic and harmful substances in the sample, reduces the occurrence of occupational diseases, and protects the safety of sampling personnel. At the same time, closed sampling reduces the possibility of sample volatilization and pollution, making laboratory analysis more accurate and reliable. In addition, by blocking the channels for sample discharge into the atmosphere, it reduces the pollution of the atmospheric environment. Therefore, the closed sampler is a multi pronged, safe, reliable, and environmentally friendly sampling device. Comply with national requirements for environmental protection, fire prevention, explosion prevention, and other regulations.

Liaoning closed sampler in stockProduct Features:
The material of the box is 304/316 stainless steel, available in two forms: box type and panel type, with rust and corrosion resistance, and a beautiful appearance.
Process gases (including gas-liquid mixtures) are sampled using steel cylinders, with quick couplings between the cylinders and sampling pipelines. The design is user-friendly, the layout is reasonable, and the operation is simple and convenient. The self sealing design of the quick couplings prevents leakage and dripping.
Liquid sampling can be done using two methods: glass bottles (ordinary open bottle&sealed pressure resistant bottle) and stainless steel sampling cylinders. The sealed pressure resistant bottle is connected to the matching double needle, and the bottle mouth is sealed with a sealing elastic pad to ensure the purity of the liquid sample.
The sampling process is equipped with an emptying and blowing port to exhaust the residual medium in the pipeline, obtaining authentic and accurate samples that are safe and environmentally friendly.
Sampling of high-temperature (low-temperature) media requires cooling (heating) to room temperature of around 20 ℃, and a cooling (heating) system can be equipped.
Equipped with a sampling steel cylinder that is formed by one-time spinning, with no welding defects and a smooth inner wall with strong anti-corrosion ability.
Users can choose to add various functions based on the different physical and chemical properties of the medium, such as external cooling system, condensation system, liquid level gauge, and boosting power system, to ensure the accuracy, convenience, and safety of the sampling process.

When using a sealed sampler, the following points should be noted:

1. Ensure good sealing performance of the sealed sampler to avoid air or liquid leakage.

When using a sealed sampler, it should be avoided to use it in environments with flammable, explosive, toxic and harmful substances to prevent danger.

When using a sealed sampler, it should be avoided to use it in harsh environments such as high temperature, high humidity, strong magnetic fields, and strong electric fields to avoid affecting the accuracy and stability of sampling.

When using a sealed sampler, it should be avoided to use it in situations where the gas flow rate is too small or too large, so as not to affect the accuracy and stability of sampling.

When using a sealed sampler, it is advisable to avoid mixing impurities such as gas or solid particles into the liquid to avoid affecting the accuracy of the analysis results.

When using a sealed sampler, it should be avoided to store it in liquid for a long time to avoid affecting the quality and stability of the liquid.

When using a sealed sampler, attention should be paid to protecting the sealing performance of the sample container to avoid container leakage or damage.

When using a sealed sampler, attention should be paid to complying with relevant safety regulations and operating procedures to ensure the safety of personnel and equipment.