Welcome Customer !

Membership

Help

Liaoning Bisun Petrochemical Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Liaoning Bisun Petrochemical Technology Co., Ltd

  • E-mail

    18242399111@139.com

  • Phone

    13842345416

  • Address

    Changchun Street East Section, Shuncheng District, Fushun City, Liaoning Province

Contact Now

Liaoning closed sampler

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Liaoning closed sampler follows the standards of GB/T4756-201 "Manual Sampling Method for Petroleum Liquids" and "Safety Requirements for Closed Sampling in Petrochemical Industry", absorbs * technology, continuously improves design and upgrades processes to meet the needs of the domestic industry, and successfully develops the BQM series closed sampler (gas/liquid closed sampler), which is safe, reliable, and easy to operate.
Product Details

Liaoning closed sampler(Liquid) process diagram, pipe opening table, and single accessory table

Taking crude benzene as an example, the medium pressure is atmospheric pressure, the medium temperature is room temperature, and the volume of the sampling bottle (glass) is 500ML.

辽宁密闭取样器

辽宁密闭取样器

IILiaoning closed samplerUsage method:

Preparation of samples: Prior to sampling, it is necessary to select appropriate sample containers and sample quantities based on the substance to be sampled and the purpose of the sampling. Generally speaking, the more samples there are, the more accurate the analysis results will be.

Connect the sample container: Connect the connecting tube of the sealed sampler to the selected sample container, ensuring a tight connection and no air leakage.

Open the sampling valve: Open the sampling valve of the sealed sampler to allow gas to enter the sample container from the sampling valve.

Adjust flow rate: Adjust the flow rate of the sealed sampler as needed to ensure that the sampling speed meets the requirements. Generally speaking, the sampling speed should be controlled within a certain range to ensure the accuracy and stability of the sampling.

Sampling time: Choose an appropriate sampling time based on the substance to be sampled and the purpose of the sampling. Generally speaking, the longer the sampling time, the more accurate the analysis results will be.

Close the sampling valve: After the sampling is completed, close the sampling valve of the sealed sampler to stop gas from entering the sample container.

Record sample information: Record information such as sampling time, location, sample quantity, sampling environment, as well as the usage of the closed sampler and the number of the sample container.

Transport samples: Transport sample containers to laboratories or analytical institutions for analysis.

3、 Other optional features

The above introduction shows that the liquid sealed sampler is a conventional type that collects media at room temperature and pressure. For different liquid media, the following functions can be added:

1. Heat tracing type: used for sampling low-temperature and easily condensable media

2. Cooling type: used for sampling high-temperature media. The cooler can be built inside the box or connected separately externally

3. Pressure reducing type: equipped with a pressure reducer, used for sampling high-pressure gaseous media to prevent overpressure damage to sampling equipment and fittings

4. Filter type: used for sampling impure media with high impurities

5. Fully automatic type: One click completion of sampling operation

4、 Installation of closed sampler

The side inlet and outlet flanges of the closed sampler can be connected to the on-site inlet and outlet flanges

辽宁密闭取样器辽宁密闭取样器

5、 Inquiry parameter table for closed sampler:


Project

detailed description

medium name


Operating pressure and temperature


Design pressure and temperature


Sampling quantity per time


Tag or tag number


Installation location


Sampler nozzle


flange


quantity







Reminder: Users need to provide our sales and technical personnel with effective on-site sampling medium pressure, temperature, medium type, and specific sampling environment.