Lightning protection soil resistivity testerIntroduction:
The soil resistivity tester, also known as the grounding resistance soil resistivity tester, precision grounding resistance tester, etc., is a commonly used instrument for testing and measuring grounding resistance. It adopts a large LCD gray white screen backlight display and microprocessor technology to meet the requirements of two, three, and four wire testing of resistance and soil resistivity. Suitable for telecommunications, power, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding grids, lightning rods, etc. The instrument testing is characterized by precision, speed, simplicity, stability, and reliability.
The soil resistivity tester is controlled by a microprocessor and can automatically detect the connection status of various interfaces and the interference voltage and frequency of the grounding grid. It also has the function of testing the resistance value of auxiliary grounding electrodes. Simultaneously storing 500 sets of data, resistance measurement range: 0.01 Ω~30.00k Ω, grounding voltage range: 0.01~100.0V. Data can be monitored online through monitoring software, USB data can be uploaded to PC, and it has intelligent alarm prompts and other functions.
The soil resistivity tester consists of a host, monitoring software, testing line, USB cable, and grounding rod, and has functions such as historical data reading, viewing, saving, reporting, and printing
Instrument structure:

1. LCD 2. H interface: current pole 3. S interface: voltage pole
4. ES interface: auxiliary grounding electrode 5. E interface: grounding electrode 6. Function buttons
7. DC charging dock 8. USB interface 9. Test button
10. Safety crocodile clip 11. Test line 12 Grounding rod
13. Simple test line 14. Short connector of simple test line

Lightning protection soil resistivity testerRange and accuracy:
Measurement function |
measurement range |
precision |
resolution |
|
grounding resistance (R) |
0.00Ω to 30.00Ω |
±2%rdg±5dgt (注1) |
0.01Ω |
30.0Ω to 300.0Ω |
±2%rdg±3dgt |
0.1Ω |
|
300Ω to 3000Ω |
±2%rdg±3dgt |
1Ω |
|
3.00kΩ~30.00kΩ |
±2%rdg±3dgt |
10Ω |
|
|
soil resistivity (ρ)
|
0.00Ωm~99.99Ωm |
ρ=2 π aR (Note 2) |
0.01Ωm |
100.0Ωm~999.9Ωm |
0.1Ωm |
||
1000Ωm~9999Ωm |
1Ωm |
||
10.00kΩm~99.99kΩm |
10Ωm |
||
100.0kΩm~999.9kΩm |
100Ωm |
||
1000kΩm~9999kΩm |
1kΩm |
||
ground voltage |
AC 0.00~100.0V |
±2%rdg±3dgt |
0.01V |
Note:1. Benchmark conditions:Rh RsAccuracy at<100 Ω.
Working conditions:Rhmax=3kΩ+100R<50kΩ;Rsmax=3kΩ+100R<50kΩ
2.depends onRThe measurement accuracy depends on π=3.14,a:1 m~100m;
Safety rules and precautions
Thank you for purchasing our soil resistivity tester. Before using the instrument for the first time, to avoid possible electric shock or personal injury, please read and strictly follow the safety rules and precautions listed in this manual.
In any case, special attention should be paid to safety when using this instrument.
This instrument is designed, produced, and inspected according to the IEC61010 safety specification.
In any case, special attention should be paid to safety when using this instrument.
When measuring, do not use the high-frequency signal generator near the instrument to avoid errors.
Pay attention to the labeling text and symbols on the body of this instrument.
Before use, it should be confirmed that the instrument and accessories are intact, and the insulation layer of the instrument and test line is not damaged or exposed
Only when there is no disconnection can it be used.
During the measurement process, it is strictly prohibited to come into contact with exposed conductors and the circuit being measured.
Confirm that the connection plug of the wire is tightly inserted into the instrument interface.
Do not apply AC or DC voltage exceeding 100V between the testing end and the interface, otherwise
Possible damage to the instrument.
Do not measure in flammable areas, sparks may cause explosions.
When the instrument is in use and the casing or test line breaks, causing metal exposure, please stop using it.
Do not place or store instruments in places with high temperature, humidity, condensation, or direct sunlight for a long time.
When charging the battery, please confirm that the test line has been removed from the instrument and the instrument is turned off.
The instrument displays the low battery voltage symbol "", and it should be charged in a timely manner.
Pay attention to the measurement range and usage environment specified by this instrument.
The use, disassembly, calibration, and maintenance of this instrument must be carried out by authorized personnel.
Due to the malfunction of this instrument, if continued use poses a danger, it should be immediately stopped and sealed
Storage shall be handled by authorized institutions.
The safety warning signs in the instrument and manual must be strictly followed by the user in accordance with this manual
Allow for safe operation.