Welcome Customer !

Membership

Help

Dongguan Gaosheng Electronic Precision Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Dongguan Gaosheng Electronic Precision Technology Co., Ltd

  • E-mail

    gaoshengkeji@163.com

  • Phone

    18128028677

  • Address

    101, Building 2, No. 6 Songbailang Xinyuan 1st Road, Dalang Town, Dongguan City, Guangdong Province

Contact Now

Multi purpose non-invasive blood pressure simulator

NegotiableUpdate on 04/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The multi-purpose non-invasive blood pressure simulator is designed and manufactured to meet the testing requirements of the JJF1626-2017 "Blood Pressure Simulator Calibration Specification".
Product Details

1、 Main features:

1. High performance (wide range of parameters for blood pressure and pulse rate settings)

2. Multifunctional (8 major tests, enable wrist customization)

3. Multi purpose (suitable for arm, wrist, pulse wave, smartwatch, and animal blood pressure monitor testing)

4. Easy to operate (full touchscreen operation)

5. No noise (no sound throughout the entire test)

2、 Compliant with standards:
SJ99KMulti purpose non-invasive blood pressure simulatorDesigned and manufactured to meet the testing requirements of JJF1626-2017 "Blood Pressure Simulator Calibration Specification".

多用途无创血压模拟器


3、 Main technical specifications:

parameter name

Multi purpose non-invasive blood pressure simulatorTechnical Specifications

pressure measurement

unit

mmHg,kPa,cmH2O,inH2O,psi

range

0 mmHg — 450 mmHg

resolution

0.1mmHg,0.1kPa,1cmH2O,1inH2O,0.1psi

precision

0-300 mmHg: ± 0.5% ± 1 mmHg of the reading value;

301-400 mmHg: ± 2% of the reading value

stressor

output pressure

50 mmhg- 450 mmHg

resolution

0.1 mmHg

Functional Testing

airtightness

At a minimum volume of 300cc,<2mmHg/min

Pressure leakage test

The pressure is provided by an internal pressure source, with a maximum of 450mmHg. The peak pressure and current pressure are always displayed, and the leakage rate is displayed after 10 seconds

Overvoltage release test

The pressure is provided by an internal pressure source, with a maximum of 450mmHg, displaying peak pressure

Pressure gauge testing

Real time measurement and display of static pressure values generated by external devices

Stress source testing

Generate measurement pressure for static calibration of blood pressure monitors or sphygmomanometers

Standard blood pressure simulation

7 preset blood pressure values, customizable

Wrist blood pressure simulation

7 preset blood pressure values, customizable

Newborn blood pressure simulation

Built in newborn cuff, 4 preset blood pressure values

Patient state simulation

8 types of patient state simulators

Cardiac arrhythmia simulation

Two types of atrial premature contractions, ventricular premature contractions, atrial fibrillation, and ventricular premature contractions

Respiratory interference simulation

3 types of spontaneous breathing, 1 type of controlled breathing

Animal standard blood pressure simulation

7 preset blood pressure values, customizable

User defined simulation

systolic blood pressure

30 - 300 ( mmHg )

diastolic pressure

10-250(mmHg)

heart rate

30-300(bpm)

Pulse volume

0.1-3.4(cc)

Simulate parameter performance

Maximum heart rate

When the pulse volume is not greater than 2.00cc: 300bpm;

When the pulse volume is greater than 2.00cc: 250bpm

Built in neonatal cuff capacity

20cc

Built in adult cuff capacity

200cc

heart rate

Except for the patient's condition

±1bpm

precision

In the patient's condition

Among them: Weak pulse and rapid heartbeat: ± 1% ± 1bpm

Obesity, elderly

Among them: Moderate exercise: ± 1.5% ± 1bpm Intense exercise: ± 3% ± 1bpm

Standard testing

JJG 270-2008、JJG692-2010、YY9706.230-2023

data scheme

Support downloading the manufacturer's own non-invasive blood pressure curve

PC control

Can connect to PC software for automated testing

power supply

Communication AC100-240V, 50/60Hz, 60VA

display

6-inch TFT screen

language

Switchable between Chinese and English

多用途无创血压模拟器

Main Interface

多用途无创血压模拟器

Stress testing interface

多用途无创血压模拟器

Blood pressure simulation interface

多用途无创血压模拟器

Standard testing interface